Standardization of 8-color flow cytometry across different flow cytometer instruments: A feasibility study in clinical laboratories in Switzerland

被引:28
|
作者
Glier, Hana [1 ]
Heijnen, Ingmar [2 ]
Hauwel, Mathieu [3 ]
Dirks, Jan [4 ]
Quarroz, Stephane [5 ]
Lehmann, Thomas [6 ]
Rovo, Alicia [4 ]
Arn, Kornelius [7 ]
Matthes, Thomas [3 ]
Hogan, Cassandra [3 ]
Keller, Peter [8 ]
Dudkiewicz, Ewa [9 ]
Stussi, Georg [10 ,11 ]
Fernandez, Paula [1 ]
机构
[1] Cantonal Hosp Aarau, Inst Lab Med, Aarau, Switzerland
[2] Univ Hosp Basel, Med Immunol, Basel, Switzerland
[3] Geneva Univ Hosp, Hematol Lab, Geneva, Switzerland
[4] Univ Hosp Basel, Diagnost Hematol, Basel, Switzerland
[5] Vaudoise Univ Hosp Ctr, Hematol Lab, Lausanne, Switzerland
[6] Ctr Lab Med, Clin Chem Hematol & Immunol Lab, St Gallen, Switzerland
[7] Cantonal Hosp, Ctr Lab Med, Luzern, Switzerland
[8] Univ Bern, Univ Clin Hematol, Univ Hosp Bern, Inselspital, Bern, Switzerland
[9] Univ Hosp Zurich, Hematol Clin, Zurich, Switzerland
[10] Reg Hosp Bellinzona & Valli, Oncol Inst Southern Switzerland, Hematol Lab, Bellinzona, Switzerland
[11] Reg Hosp Bellinzona & Valli, EOLAB, Bellinzona, Switzerland
关键词
Flow cytometry; Cross-platform standardization; Canto; Navios; EuroFlow;
D O I
10.1016/j.jim.2017.07.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The EuroFlow Consortium developed a fully standardized flow cytometric approach from instrument settings, through antibody panel, reagents and sample preparation protocols, to data acquisition and analysis. The Swiss Cytometry Society (SCS) promoted a study to evaluate the feasibility of using such standardized measurements of 8-color data across two different flow cytometry platforms - Becton Dickinson (BD) FACSCanto II and Beckman Coulter (BC) Navios, aiming at increasing reproducibility and inter-laboratory comparability of immunophenotypic data in clinical laboratories in Switzerland. The study was performed in two phases, i.e. a learning phase (round 1) and an analytical phase (rounds 2 and 3) consisting of a total of three rounds. Overall, 10 laboratories using BD FACSCanto II (n = 6) or BC Navios (n = 4) flow cytometers participated. Each laboratory measured peripheral blood samples from healthy donors stained with a uniform antibody panel of reagents - EuroFlow Lymphoid Screening Tube (LST) - applying the EuroFlow standardized protocols for instrument setup and sample preparation (www.EuroFlow.org). All data files were analyzed centrally and median fluorescence intensity (MedFI) values for individual markers on defined lymphocyte subsets were recorded; variability from reference MedFI values was assessed using performance scores. Data troubleshooting and discussion of the results with the participants followed after each round at SCS meetings. The results of the learning phase demonstrated that standardized instrument setup and data acquisition are feasible in routine clinical laboratories without previous experience with EuroFlow. During the analytical phase, highly comparable data were obtained at the different laboratories using either BD FACSCanto II or BC Navios. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%. In the last study round, 89% of participants scored over 90% MedFI values within the acceptance criteria (P-score), in line with the results of the EuroFlow quality assessment rounds performed by the EuroFlow expert laboratories(Kalina et al., 2015). Central analysis of data allowed identification of deviations from the standardized procedures and technical issues (e.g. failure to perform correct instrument setup and improper compensation). In summary, here we show that inter-laboratory cross-platform standardization of 8-color flow cytometric measurements in clinical laboratories is feasible and allows for fully comparable MedFI results across BD FACSCanto II and BC Navios instruments. However, adherence to standardized protocols is crucial. Thus, training of the laboratory personnel in the EuroFlow standardized procedures is highly recommended to prevent errors in instrument setup and sample preparation.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] IMPLEMENTATION OF 8-COLOR FLOW CYTOMETRY IN A CLINICAL LABORATORY
    Sewell, William
    Smith, Sandy
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2011, 80B (06) : 400 - 400
  • [2] StarBright Dyes - Simplifying Flow Cytometry with 8-color No Compensation Panels
    Sanderson, Sharon
    Santos, Magda
    Perike, Srikanth
    Dreskin, Elizabeth
    Blundell, Michael
    Long, Tracey
    JOURNAL OF IMMUNOLOGY, 2024, 212 (01):
  • [3] Characterization of Plasma Cell Disorders with Clonal Heterogeneity by 8-Color Flow Cytometry
    Booth, C. L.
    Timm, M. M.
    Hanson, C. A.
    Reichard, K. K.
    Ketterling, R. P.
    Morice, W. G.
    MODERN PATHOLOGY, 2014, 27 : 337A - 337A
  • [4] NEW STRATEGIES OF MINIMUM RESIDUAL DISEASE ANALYSIS IN ACUTE MYELOBLASTIC LEUKEMIA BY 8-COLOR FLOW CYTOMETRY IN THE AGE OF STANDARDIZATION
    Sarmiento Palao, H.
    Diaz Rodriguez, V
    Lopez Marin, J.
    Lopez Castano, F.
    Arranz Oliva, E.
    Manresa Manresa, P.
    Perez Sala, M.
    Garcia Hernandez, C.
    Gil Cortes, C.
    Botella Prieto, C.
    Verdu Belmar, J. J.
    De Paz Andres, F. J.
    Fernandez Abellan, P.
    Marco Vera, P.
    Ruiz Sogorb, P.
    Cobo, J.
    Tarin Rodrigo, F.
    HAEMATOLOGICA, 2018, 103 : 49 - 50
  • [5] AN 8-COLOR PANEL FOR DETECTION OF HUMAN BLOOD DENDRITIC CELLS BY FLOW CYTOMETRY
    Gautherot, Emmanuel
    Dupas, Nathalie
    Kverneland, Anders
    Streitz, Mathias
    Sawitzki, Birgit
    Montero-Julian, Felix
    Miloud, Tewfik
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2013, 84 (06) : 408 - 408
  • [6] An 8-color panel for detection of human blood dendritic cells by flow cytometry
    Miloud, Tewfik
    Dupas, Nathalie
    Montero-Julian, Felix
    JOURNAL OF IMMUNOLOGY, 2013, 190
  • [7] Characterization of Plasma Cell Disorders with Clonal Heterogeneity by 8-Color Flow Cytometry
    Booth, C. L.
    timm, M. M.
    Hanson, C. A.
    Reichard, K. K.
    Ketterling, R. P.
    Morice, W. G.
    LABORATORY INVESTIGATION, 2014, 94 : 337A - 337A
  • [8] Cerebrospinal fluid analysis by 8-color flow cytometry in children with acute lymphoblastic leukemia
    Gabelli, Maria
    Disaro, Silvia
    Scarparo, Pamela
    Francescato, Samuela
    Zangrando, Andrea
    Valsecchi, M. Grazia
    Putti, M. Caterina
    Basso, Giuseppe
    Buldini, Barbara
    LEUKEMIA & LYMPHOMA, 2019, 60 (11) : 2825 - 2828
  • [9] High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
    Chan, Ray Chun-Fai
    Leung, Richard H.
    Posadas, Albert
    Lorey, Thomas S.
    Shaw, Allison J.
    BIOMEDICAL REPORTS, 2018, 8 (03) : 224 - 234
  • [10] PERFORMANCE OF 8-COLOR DRY REAGENT TUBE FOR MRD DETECTION IN CHRONIC LYMPHOCYTIC LEUKEMIA BY FLOW CYTOMETRY
    Correia, Rodolfo Patussi
    Bento, Laiz Cameirao
    Barroso, Rodrigo de Souza
    Bacal, Nydia Strachman
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 : 141 - 141