A Comparison of Postprandial Glucose Control in the Medtronic Advanced Hybrid Closed-Loop System Versus 670G

被引:13
|
作者
Weinzimer, Stuart A. [1 ]
Bailey, Ryan J. [2 ]
Bergenstal, Richard M. [3 ]
Nimri, Revital [4 ]
Beck, Roy W. [2 ]
Schatz, Desmond [5 ]
Ambler-Osborn, Louise [6 ]
Schweiger, Darja Smigoc [7 ,8 ]
von dem Berge, Thekla [9 ]
Sibayan, Judy [2 ]
Johnson, Mary L. [3 ]
Calhoun, Peter [2 ]
Phillip, Moshe [4 ]
Criego, Amy
Carlson, Anders
Martens, Thomas
Beasley, Shannon
Whipple, Diane
Hyatt, Jamie
Punel, Alina
Grieme, Aimee
Thomas, Lee Ann
LaFrance, Amy
Hasledalen, Caitlin
Laffel, Lori
Isganaitis, Elvira
Freiner, Emily
Desrochers, Hannah
Turcotte, Christine
Naik, Nisha
Roethke, Lindsay
Fisher, Margaret
Nevo, Michal
Bello, Rachel
Hamou, Alona
Hermon, Orna
Horesh, Orit
Mantzuri, Galit Shiovitch
Drotz, Irit
Yehiel, Nava
Naveh, Rachel
Haller, Michael
Albanese-O'Neill, Anastasia
Sheehan, Eleni
Sheehan, Eleni
Smith, Madison
Jacobsen, Laura
Adams, Janey
Hosford, Jennifer
Whyte, Loren
机构
[1] Yale Univ, Dept Pediat, Yale Sch Med, 1 Long Wharf Dr,Suite 503, New Haven, CT 06511 USA
[2] Jaeb Ctr Hlth Res Fdn Inc, Tampa, FL USA
[3] HealthPartners Inst, Int Diabet Ctr, Minneapolis, MN USA
[4] Univ Florida, Coll Med, Dept Pediat, Gainesville, FL USA
[5] Univ Florida, Coll Med, Gainesville, FL USA
[6] Harvard Med Sch, Joslin Diabet Ctr, Boston, MA 02115 USA
[7] Univ Childrens Hosp, Univ Med Ctr Ljubljana, Ljubljana, Slovenia
[8] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[9] Auf Der Bult Ctr Children & Adolescents, Hannover, Germany
基金
美国国家卫生研究院;
关键词
Postprandial blood glucose; Closed-loop system; Adolescents; Young adults; INSULIN DELIVERY-SYSTEM; ARTIFICIAL PANCREAS; HOME-USE; TYPE-1; CROSSOVER; ADULTS; MULTICENTER; ADOLESCENTS;
D O I
10.1089/dia.2021.0568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We recently reported that use of an "advanced" hybrid closed-loop system reduced hyperglycemia without increasing hypoglycemia compared to a first-generation system. The aim of this analysis was to evaluate whether this improved performance was specifically related to better mealtime glycemic control.Methods: We conducted a secondary analysis of postprandial glycemic control in an open-label, multinational, randomized crossover trial of 112 participants with type 1 diabetes, aged 14-29, of the Medtronic MiniMed (TM) 670G hybrid closed-loop system (670G) versus the Medtronic advanced hybrid closed-loop (AHCL) system, for 12 weeks each. We compared glycemic and insulin delivery metrics over a 3 h horizon across all meals to assess system performance and outcomes.Results: Overall meal size and premeal insulin on board were similar during run-in and between 670G and AHCL arms. Compared with 670G arm, premeal, peak, and mean glucose levels were numerically lower in the AHCL arm (167 +/- 23, 231 +/- 23, and 177 +/- 20 mg/dL vs. 175 +/- 23, 235 +/- 23, and 180 +/- 19 mg/dL, respectively), with a trend to lower hyperglycemia level 2 in AHCL arm. Adjusting for premeal glucose level, all postmeal outcomes between 670G and AHCL were statistically similar. Prandial insulin delivery also was similar in both treatment arms (21 +/- 9 vs. 23 +/- 10 U), with a shift in basal/bolus ratio from 28%/71% in 670G arm to 20%/80% in AHCL arm.Conclusions: Reduced hyperglycemia with AHCL compared to 670G was not related to early postprandial glycemic excursions after adjusting for premeal glucose level (<3 h after meal), but likely to later (>3 h) postprandial or overnight improvements. Further refinements to mealtime bolus algorithms and strategies may more optimally control prandial glycemic excursions.
引用
收藏
页码:573 / 582
页数:10
相关论文
共 50 条
  • [41] Glucose Control in Adults with Type 1 Diabetes Using a Medtronic Prototype Enhanced-Hybrid Closed-Loop System: A Feasibility Study
    Lee, Melissa H.
    Vogrin, Sara
    Paldus, Barbora
    Jones, Hannah M.
    Obeyesekere, Varuni
    Sims, Catriona
    Wyatt, Sue-Anne
    Ward, Glenn M.
    McAuley, Sybil A.
    MacIsaac, Richard J.
    Krishnamurthy, Balasubramanian
    Sundararajan, Vijaya
    Jenkins, Alicia J.
    O'Neal, David N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (09) : 499 - 506
  • [42] GLUCOSE CONTROL IN ADULTS WITH TYPE 1 DIABETES USING A MEDTRONIC ENHANCED-HYBRID CLOSED-LOOP SYSTEM (E-HCL)
    Lee, M.
    Paldus, B.
    Jones, H.
    Vogrin, S.
    Obeyesekere, V.
    Sims, C.
    Wyatt, S.
    Ward, G.
    McAuley, S.
    MacIsaac, R.
    Krishnamurthy, B.
    Sundararajan, V.
    Jenkins, A.
    O'Neal, D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A37 - A38
  • [43] Glucose Control following Missed and Late Meal Boluses with a Medtronic Enhanced-Hybrid Closed-Loop (E-HCL) System
    Lee, Melissa H.
    Vogrin, Sara
    Paldus, Barbora
    Jones, Hannah
    Obeyesekere, Varuni R.
    Sims, Catriona M.
    Wyatt, Sue A.
    Ward, Glenn M.
    Mcauley, Sybil A.
    Macisaac, Richard
    Krishnamurthy, Balasubramanian
    Sundararajan, Vijaya
    Alicia, Jenkins
    O'Neal, David N.
    DIABETES, 2019, 68
  • [44] Lived Experience of Advanced Hybrid Closed-Loop Versus Hybrid Closed-Loop: Patient-Reported Outcomes and Perspectives
    Hood, Korey K.
    Laffel, Lori M.
    Danne, Thomas
    Nimri, Revital
    Weinzimer, Stuart A.
    Sibayan, Judy
    Bailey, Ryan J.
    Schatz, Desmond
    Bratina, Natasa
    Bello, Rachel
    Punel, Alina
    Calhoun, Peter
    Beck, Roy W.
    Bergenstal, Richard M.
    Phillip, Moshe
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (12) : 857 - 861
  • [45] MINIMED™ 670G PIVOTAL TRIAL: TIMING OF MEAL BOLUS PLAYS A CRITICAL ROLE IN POSTPRANDIAL GLUCOSE CONTROL
    Roy, A.
    Grosman, B.
    Parikh, N.
    Wu, D.
    Lee, S.
    Kaufman, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A87 - A87
  • [46] Real-World, Patient-Reported and Clinic Data from Individuals with Type 1 Diabetes Using the MiniMed 670G Hybrid Closed-Loop System
    DuBose, Stephanie N.
    Bauza, Colleen
    Verdejo, Alandra
    Beck, Roy W.
    Bergenstal, Richard M.
    Sherr, Jennifer
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (12) : 791 - 798
  • [47] The Medtronic 780G advanced hybrid closed-loop system achieves and maintains good glycaemic control in type 1 diabetes adults despite previous treatment
    Quiroes, Carmen
    Alonso-Carril, Nuria
    Rodriguez-Rodriguez, Silvia
    Barahona, Maria-Jose
    Orois, Aida
    Simoe-Servat, Andreu
    Ramos, Montserrat
    Perea, Veronica
    ENDOCRINOLOGIA DIABETES Y NUTRICION, 2023, 70 (02): : 130 - 135
  • [48] Fast-acting insulin aspart (Fiasp®) improves glycemic outcomes when used with MiniMed™ 670G hybrid closed-loop system in simulated trials compared to NovoLog®
    Grosman, Benyamin
    Wu, Di
    Parikh, Neha
    Roy, Anirban
    Voskanyan, Gayane
    Kurtz, Natalie
    Sturis, Jeppe
    Cohen, Ohad
    Ekelund, Magnus
    Vigersky, Robert
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 205
  • [49] PANCREATIC DIABETES EFFECTIVENESS OF AN ADVANCED HYBRID CLOSED-LOOP SYSTEM
    Fernandez-Bueso, M. M.
    Ambrojo Lopez, A.
    Guijarro-Chacon, M. M.
    Nicolas-Blanco, M.
    Beato-Vibora, P. I.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A114 - A115
  • [50] COMPLEX MEAL HANDLING WITH ADVANCED HYBRID CLOSED-LOOP SYSTEM
    Laron-Hirsh, M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A22 - A22