A Comparison of Postprandial Glucose Control in the Medtronic Advanced Hybrid Closed-Loop System Versus 670G

被引:13
|
作者
Weinzimer, Stuart A. [1 ]
Bailey, Ryan J. [2 ]
Bergenstal, Richard M. [3 ]
Nimri, Revital [4 ]
Beck, Roy W. [2 ]
Schatz, Desmond [5 ]
Ambler-Osborn, Louise [6 ]
Schweiger, Darja Smigoc [7 ,8 ]
von dem Berge, Thekla [9 ]
Sibayan, Judy [2 ]
Johnson, Mary L. [3 ]
Calhoun, Peter [2 ]
Phillip, Moshe [4 ]
Criego, Amy
Carlson, Anders
Martens, Thomas
Beasley, Shannon
Whipple, Diane
Hyatt, Jamie
Punel, Alina
Grieme, Aimee
Thomas, Lee Ann
LaFrance, Amy
Hasledalen, Caitlin
Laffel, Lori
Isganaitis, Elvira
Freiner, Emily
Desrochers, Hannah
Turcotte, Christine
Naik, Nisha
Roethke, Lindsay
Fisher, Margaret
Nevo, Michal
Bello, Rachel
Hamou, Alona
Hermon, Orna
Horesh, Orit
Mantzuri, Galit Shiovitch
Drotz, Irit
Yehiel, Nava
Naveh, Rachel
Haller, Michael
Albanese-O'Neill, Anastasia
Sheehan, Eleni
Sheehan, Eleni
Smith, Madison
Jacobsen, Laura
Adams, Janey
Hosford, Jennifer
Whyte, Loren
机构
[1] Yale Univ, Dept Pediat, Yale Sch Med, 1 Long Wharf Dr,Suite 503, New Haven, CT 06511 USA
[2] Jaeb Ctr Hlth Res Fdn Inc, Tampa, FL USA
[3] HealthPartners Inst, Int Diabet Ctr, Minneapolis, MN USA
[4] Univ Florida, Coll Med, Dept Pediat, Gainesville, FL USA
[5] Univ Florida, Coll Med, Gainesville, FL USA
[6] Harvard Med Sch, Joslin Diabet Ctr, Boston, MA 02115 USA
[7] Univ Childrens Hosp, Univ Med Ctr Ljubljana, Ljubljana, Slovenia
[8] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[9] Auf Der Bult Ctr Children & Adolescents, Hannover, Germany
基金
美国国家卫生研究院;
关键词
Postprandial blood glucose; Closed-loop system; Adolescents; Young adults; INSULIN DELIVERY-SYSTEM; ARTIFICIAL PANCREAS; HOME-USE; TYPE-1; CROSSOVER; ADULTS; MULTICENTER; ADOLESCENTS;
D O I
10.1089/dia.2021.0568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We recently reported that use of an "advanced" hybrid closed-loop system reduced hyperglycemia without increasing hypoglycemia compared to a first-generation system. The aim of this analysis was to evaluate whether this improved performance was specifically related to better mealtime glycemic control.Methods: We conducted a secondary analysis of postprandial glycemic control in an open-label, multinational, randomized crossover trial of 112 participants with type 1 diabetes, aged 14-29, of the Medtronic MiniMed (TM) 670G hybrid closed-loop system (670G) versus the Medtronic advanced hybrid closed-loop (AHCL) system, for 12 weeks each. We compared glycemic and insulin delivery metrics over a 3 h horizon across all meals to assess system performance and outcomes.Results: Overall meal size and premeal insulin on board were similar during run-in and between 670G and AHCL arms. Compared with 670G arm, premeal, peak, and mean glucose levels were numerically lower in the AHCL arm (167 +/- 23, 231 +/- 23, and 177 +/- 20 mg/dL vs. 175 +/- 23, 235 +/- 23, and 180 +/- 19 mg/dL, respectively), with a trend to lower hyperglycemia level 2 in AHCL arm. Adjusting for premeal glucose level, all postmeal outcomes between 670G and AHCL were statistically similar. Prandial insulin delivery also was similar in both treatment arms (21 +/- 9 vs. 23 +/- 10 U), with a shift in basal/bolus ratio from 28%/71% in 670G arm to 20%/80% in AHCL arm.Conclusions: Reduced hyperglycemia with AHCL compared to 670G was not related to early postprandial glycemic excursions after adjusting for premeal glucose level (<3 h after meal), but likely to later (>3 h) postprandial or overnight improvements. Further refinements to mealtime bolus algorithms and strategies may more optimally control prandial glycemic excursions.
引用
收藏
页码:573 / 582
页数:10
相关论文
共 50 条
  • [21] EXPLORATORY ANALYSIS OF HYBRID CLOSED-LOOP ALGORITHM ADAPTATION DURING MINIMED™ 670G SYSTEM USE BY CHILDREN, ADOLESCENTS, AND ADULTS
    Shin, J.
    Liu, M.
    Chen, X.
    Huang, S. Huang
    Cordero, T.
    Lee, S.
    Kaufman, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A82 - A83
  • [22] Real world hybrid closed-loop discontinuation: Predictors and perceptions of youth discontinuing the 670G system in the first 6 months
    Messer, Laurel H.
    Berget, Cari
    Vigers, Tim
    Pyle, Laura
    Geno, Cristy
    Wadwa, R. Paul
    Driscoll, Kimberly A.
    Forlenza, Gregory P.
    PEDIATRIC DIABETES, 2020, 21 (02) : 319 - 327
  • [23] Overnight to Early-Morning Glycemic Outcomes in Children Using the MiniMed™ 670G Hybrid Closed-Loop (HCL) System
    Forlenza, Gregory P.
    Shulman, Dorothy I.
    Wood, Michael A.
    Bailey, Timothy S.
    Bode, Bruce W.
    Buckingham, Bruce
    Huang, Suiying
    Shin, John
    Lee, Scott W.
    Cordero, Toni L.
    Kaufman, Francine R.
    DIABETES, 2018, 67
  • [24] Postprandial glucose control using the Medtronic Advanced Hybrid Closed Loop System: faster-acting insulin aspart vs insulin aspart
    Lee, M. H.
    Vogrin, S.
    Paldus, B.
    Morrison, D.
    Zaharieva, D.
    Lu, J.
    Jones, H.
    Netzer, E.
    Sims, C.
    MacIsaac, R. J.
    Grosman, B.
    Roy, A.
    Kurtz, N.
    Jenkins, A.
    O'Neal, D. N.
    DIABETOLOGIA, 2020, 63 (SUPPL 1) : S328 - S328
  • [25] Cost-Effectiveness Analysis of the MiniMed 670G Hybrid Closed-Loop System Versus Continuous Subcutaneous Insulin Infusion for Treatment of Type 1 Diabetes
    Jendle, Johan
    Pohlmann, Johannes
    de Portu, Simona
    Smith-Palmer, Jayne
    Roze, Stephane
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (03) : 110 - 118
  • [26] Increased time in range and sustained AutoMode use in 670G hybrid closed-loop system users: real world experience in DIABETER
    Mul, D.
    Arrieta, A.
    Dekker, P.
    Birnie, E.
    Sas, T. C. J.
    Aanstoot, H. -J.
    Veeze, H. J.
    DIABETOLOGIA, 2020, 63 (SUPPL 1) : S86 - S86
  • [27] Comparison of Six Months Experience on Hybrid Closed Loop MiniMed 670G System and Advanced Hybrid Closed Loop MiniMed 780G System Using a Structured Initiation Protocol in Children and Adolescents with Type 1 Diabetes
    Petrovski, Goran
    Campbell, Judith
    Alkhalaf, Fawziya
    Hussain, Khalid
    DIABETES, 2022, 71
  • [28] EXPLORATORY ANALYSIS FOR SELECTED PATIENTS WITH DAWN PHENOMENON DURING THEMINIMED™ 670G HYBRID CLOSED-LOOP PIVOTAL TRIAL
    Bergenstal, R.
    Cordero, T.
    Chen, X.
    Liu, M.
    Shin, L.
    Shin, J.
    Kaufman, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A83 - A84
  • [29] TRANSLATING STANDARD CLINICAL PROTOCOL INTO TUNING PROCEDURES FOR HYBRID CLOSED LOOP SYSTEMS: 670G, CONTROL-IQ AND LOOP
    Kushner, T.
    Forlenza, G.
    Messer, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A79 - A79
  • [30] INTEGRATED INSULIN PUMP AND CONTINUOUS GLUCOSE MONITORING TECHNOLOGY IN DIABETES CARE TODAY: A PERSPECTIVE OF REAL-LIFE EXPERIENCE WITH THE MINIMED™ 670G HYBRID CLOSED-LOOP SYSTEM
    Aleppo, Grazia
    Webb, Kimberly M.
    ENDOCRINE PRACTICE, 2018, 24 (07) : 684 - 692