A Comparison of Postprandial Glucose Control in the Medtronic Advanced Hybrid Closed-Loop System Versus 670G

被引:13
|
作者
Weinzimer, Stuart A. [1 ]
Bailey, Ryan J. [2 ]
Bergenstal, Richard M. [3 ]
Nimri, Revital [4 ]
Beck, Roy W. [2 ]
Schatz, Desmond [5 ]
Ambler-Osborn, Louise [6 ]
Schweiger, Darja Smigoc [7 ,8 ]
von dem Berge, Thekla [9 ]
Sibayan, Judy [2 ]
Johnson, Mary L. [3 ]
Calhoun, Peter [2 ]
Phillip, Moshe [4 ]
Criego, Amy
Carlson, Anders
Martens, Thomas
Beasley, Shannon
Whipple, Diane
Hyatt, Jamie
Punel, Alina
Grieme, Aimee
Thomas, Lee Ann
LaFrance, Amy
Hasledalen, Caitlin
Laffel, Lori
Isganaitis, Elvira
Freiner, Emily
Desrochers, Hannah
Turcotte, Christine
Naik, Nisha
Roethke, Lindsay
Fisher, Margaret
Nevo, Michal
Bello, Rachel
Hamou, Alona
Hermon, Orna
Horesh, Orit
Mantzuri, Galit Shiovitch
Drotz, Irit
Yehiel, Nava
Naveh, Rachel
Haller, Michael
Albanese-O'Neill, Anastasia
Sheehan, Eleni
Sheehan, Eleni
Smith, Madison
Jacobsen, Laura
Adams, Janey
Hosford, Jennifer
Whyte, Loren
机构
[1] Yale Univ, Dept Pediat, Yale Sch Med, 1 Long Wharf Dr,Suite 503, New Haven, CT 06511 USA
[2] Jaeb Ctr Hlth Res Fdn Inc, Tampa, FL USA
[3] HealthPartners Inst, Int Diabet Ctr, Minneapolis, MN USA
[4] Univ Florida, Coll Med, Dept Pediat, Gainesville, FL USA
[5] Univ Florida, Coll Med, Gainesville, FL USA
[6] Harvard Med Sch, Joslin Diabet Ctr, Boston, MA 02115 USA
[7] Univ Childrens Hosp, Univ Med Ctr Ljubljana, Ljubljana, Slovenia
[8] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[9] Auf Der Bult Ctr Children & Adolescents, Hannover, Germany
基金
美国国家卫生研究院;
关键词
Postprandial blood glucose; Closed-loop system; Adolescents; Young adults; INSULIN DELIVERY-SYSTEM; ARTIFICIAL PANCREAS; HOME-USE; TYPE-1; CROSSOVER; ADULTS; MULTICENTER; ADOLESCENTS;
D O I
10.1089/dia.2021.0568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We recently reported that use of an "advanced" hybrid closed-loop system reduced hyperglycemia without increasing hypoglycemia compared to a first-generation system. The aim of this analysis was to evaluate whether this improved performance was specifically related to better mealtime glycemic control.Methods: We conducted a secondary analysis of postprandial glycemic control in an open-label, multinational, randomized crossover trial of 112 participants with type 1 diabetes, aged 14-29, of the Medtronic MiniMed (TM) 670G hybrid closed-loop system (670G) versus the Medtronic advanced hybrid closed-loop (AHCL) system, for 12 weeks each. We compared glycemic and insulin delivery metrics over a 3 h horizon across all meals to assess system performance and outcomes.Results: Overall meal size and premeal insulin on board were similar during run-in and between 670G and AHCL arms. Compared with 670G arm, premeal, peak, and mean glucose levels were numerically lower in the AHCL arm (167 +/- 23, 231 +/- 23, and 177 +/- 20 mg/dL vs. 175 +/- 23, 235 +/- 23, and 180 +/- 19 mg/dL, respectively), with a trend to lower hyperglycemia level 2 in AHCL arm. Adjusting for premeal glucose level, all postmeal outcomes between 670G and AHCL were statistically similar. Prandial insulin delivery also was similar in both treatment arms (21 +/- 9 vs. 23 +/- 10 U), with a shift in basal/bolus ratio from 28%/71% in 670G arm to 20%/80% in AHCL arm.Conclusions: Reduced hyperglycemia with AHCL compared to 670G was not related to early postprandial glycemic excursions after adjusting for premeal glucose level (<3 h after meal), but likely to later (>3 h) postprandial or overnight improvements. Further refinements to mealtime bolus algorithms and strategies may more optimally control prandial glycemic excursions.
引用
收藏
页码:573 / 582
页数:10
相关论文
共 50 条
  • [1] ENLITE3 CONTINUOUS GLUCOSE SENSOR ACCURACY DURING INPATIENT AND OUTPATIENT HYBRID CLOSED-LOOP CONTROL WITH MEDTRONIC 670G SYSTEM
    Buckingham, B.
    Shah, R.
    Shin, J.
    Shanmugham, S.
    Clinton, P.
    Ly, T.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A72 - A73
  • [2] Minimed 670G: A Hybrid Closed-Loop Insulin Delivery System
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 2016, 58 (1508): : 147 - 148
  • [3] HYBRID CLOSED-LOOP CONTROL USING THE MEDTRONIC 670G AND ENLITE3 SYSTEM IN TYPE 1 DIABETES AT DIABETES CAMP
    Ly, T.
    Roy, A.
    Grosman, B.
    Shin, J.
    Campbell, A.
    Monirabbasi, S.
    Liang, B.
    Shanmugham, S.
    Clinton, P.
    Buckingham, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A20 - A20
  • [4] REAL-WORLD ASSESSMENT OF FORMER MDI PATIENTS' EXPERIENCE ON THE MEDTRONIC MINIMED™ 670G HYBRID CLOSED-LOOP SYSTEM
    Gopalakrishnan, S.
    Mueckler, J.
    Jinghua, C.
    Jordin, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A85 - A86
  • [5] Role of Appropriate Premeal Insulin Bolus on the Hybrid Closed-Loop System 670G
    Roy, Anirban
    Grosman, Benyamin
    Bergenstal, Richard M.
    Bode, Bruce W.
    Buckingham, Bruce A.
    Garg, Satish K.
    Lee, Scott
    Kaufman, Francine
    DIABETES, 2017, 66 : A277 - A277
  • [6] Glucose control during Ramadan fasting in a teenager with type 1 diabetes on MiniMed 670G hybrid closed-loop system
    Petrovski, Goran
    Al Khalaf, Fawziya
    Campbell, Judith
    Hussain, Khalid
    Fisher, Hannah
    Umer, Fareeda
    ACTA DIABETOLOGICA, 2020, 57 (01) : 105 - 107
  • [7] Glucose control during Ramadan fasting in a teenager with type 1 diabetes on MiniMed 670G hybrid closed-loop system
    Goran Petrovski
    Fawziya Al Khalaf
    Judith Campbell
    Khalid Hussain
    Hannah Fisher
    Fareeda Umer
    Acta Diabetologica, 2020, 57 : 105 - 107
  • [8] REAL-WORLD USE OF THE MINIMED™ 670G HYBRID CLOSED-LOOP SYSTEM
    Agrawal, P.
    Stone, M.
    Cordero, T.
    Lee, S.
    Shin, J.
    Kaufman, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A18 - A19
  • [9] ULTRA RAPID LISPRO (URLI) DEMONSTRATES SIMILAR TIME IN TARGET RANGE TO LISPRO WITH THE MEDTRONIC MINIMED 670G HYBRID CLOSED-LOOP SYSTEM
    Carlson, A.
    Liu, R.
    Hardy, T.
    Boyd, J.
    Bergenstal, R.
    Morrett, S.
    Ignaut, D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A85 - A86
  • [10] Ultra Rapid Lispro (URLi) demonstrates similar time in target range to Lispro with the Medtronic MiniMed 670G hybrid closed-loop system
    Bode, B.
    Carlson, A.
    Liu, R.
    Hardy, T.
    Boyd, J.
    Bergenstal, R.
    Morrett, S.
    Ignaut, D.
    DIABETOLOGIA, 2020, 63 (SUPPL 1) : S327 - S327