Diagnostic utility of endoscopic ultrasonography-elastography in the evaluation of solid pancreatic masses: a meta-analysis and systematic review

被引:27
|
作者
Lu, Yi [1 ]
Chen, Lu [2 ]
Li, Chujun [1 ]
Chen, Honglei [1 ]
Chen, Jinhua [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 6, Digest Endoscopy Ctr, 26 Yuancun Erheng Rd, Guangzhou 510655, Guangdong, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Dept Gastroenterol, Ruijin Hosp,Digest Endoscopy Ctr, Shanghai, Peoples R China
关键词
endoscopic ultrasonography; elastography; contrast-enhanced EUS; EUS-guided fine needle aspiration; pancreatic masses; REAL-TIME ELASTOGRAPHY; ULTRASOUND-ELASTOGRAPHY; EUS-ELASTOGRAPHY; DIFFERENTIAL-DIAGNOSIS; STRAIN RATIO; LESIONS; ACCURACY; FNA; MULTICENTER; ADENOCARCINOMA;
D O I
10.11152/mu-987
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: The accuracy for endoscopic ultrasonography-elastography ( EUS-EG) in the evaluation of solid pancreatic masses varies greatly and the pooled results have not been updated since 2013. Also, there still lack a comprehensive comparison among EUS-EG, contrast-enhanced EUS (CE-EUS), and EUS-guided fine needle aspiration (EUS-FNA). Material and methods: A thorough search was made for diagnostic trials investigating the role of EUS-EG in solid pancreatic masses. Meta-Disc was used to calculate the pooled sensitivity, specificity, diagnostic odds ratio and summary receiver operator characteristics. Results: Finally, 17 studies (1537 patients, 1544 lesions) were selected. The pooled sensitivity and specificity for qualitative methods were 0.97 (95% CI, 0.95-0.99) and 0.67 (95% CI, 0.59-0.74), respectively; the pooled sensitivity and specificity for strain histograms were 0.97 (95% CI, 0.95-0.98) and 0.67(95% CI, 0.61-0.73), respectively; the pooled sensitivity and specificity for strain ratio were 0.98 (95% CI, 0.96-0.99) and 0.62 (95% CI, 0.56-0.68), respectively; the pooled sensitivity and specificity for CE-EUS were 0.90 (95% CI, 0.83-0.95) and 0.76 (95% CI, 0.67-0.84), respectively; the pooled sensitivity and specificity for EUS-FNA were 0.84 (95% CI, 0.77-0.90) and 0.96(95% CI, 0.88-1.00), respectively. Conclusion: EUS-EG is reliable for distinguishing solid pancreatic masses; the sensitivity and specificity for different diagnostic methods were very close. Both EUS-EG and CE-EUS can be valuable complementary supplements for EUS-FNA.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 50 条
  • [41] Effect of the number of passes on diagnostic performance of EUS fi ne-needle biopsy of solid pancreatic masses: a systematic review and meta-analysis
    Chalhoub, Jean M.
    Hawa, Fadi
    Grantham, Tyler
    Lester, Janice
    Carpenter, Eileen S.
    Mendoza-Ladd, Antonio
    Wani, Sachin
    Machicado, Jorge D.
    GASTROINTESTINAL ENDOSCOPY, 2024, 100 (04)
  • [42] Diagnostic Accuracy of Ultrasonography for Detection of Intussusception in Children; a Systematic Review and Meta-Analysis
    Rahmani, Erfan
    Amani-Beni, Reza
    Hekmatnia, Yasaman
    Yaseri, Amirhossein Fakhre
    Ahadiat, Seyed Amirabbas
    Boroujeni, Parham Talebi
    Kiani, Moein
    Tavakoli, Reza
    Shafagh, Seyyed-Ghavam
    Shirazinia, Matin
    Garousi, Setareh
    Mottahedi, Mehran
    Arzaghi, Mohammadreza
    Benam, Sasan Pourbagher
    Rigi, Amir
    Salmani, Amir
    Abdollahi, Zeynab
    Rokni, Fateme Karimzade
    Nikbakht, Tara
    Abadi, Saeme Azizi Hassan
    Roohinezhad, Roozbeh
    Masheghati, Forough
    Haririan, Yas
    Darouei, Bahar
    Fayyazishishavan, Ehsan
    Manoochehri-Arash, Niusha
    Farrokhi, Mehrdad
    ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2023, 11 (01)
  • [43] Utility of Endoscopic Ultrasound in Diagnosing Pancreatic Malignancy That Is Not Detectable on a Multidetector CT Scan: A Meta-Analysis and Systematic Review
    Moole, Harsha
    Forcione, David G.
    Bechtold, Matthew L.
    Puli, Srinivas R.
    GASTROENTEROLOGY, 2016, 150 (04) : S512 - S512
  • [44] Appendicitis in pregnant women: A systematic review and meta-analysis of the diagnostic performance of ultrasonography
    Wang, Zimo
    Bao, Fuxing
    Liang, Weiyu
    Wu, Huaiyu
    Lin, Ziwei
    Xu, Jinfeng
    Dong, Fajin
    JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (09) : 1492 - 1501
  • [45] Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis
    Goodacre S.
    Sampson F.
    Thomas S.
    van Beek E.
    Sutton A.
    BMC Medical Imaging, 5 (1)
  • [46] A meta-analysis on the efficacy of endoscopic ultrasonography for treatment of pancreatic cancer
    Xuan, Min
    Li, Na
    Wu, Chunyan
    CLINICS, 2024, 79
  • [47] Systematic review and meta-analysis: diagnostic accuracy of exosomes in pancreatic cancer
    Xu, Xinyi
    Long, Chunyue
    Li, Meng
    Shen, Chen
    Ye, Qiuwen
    Li, Yong
    Li, Hongyang
    Cao, Xia
    Ma, Jun
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2025, 23 (01)
  • [48] Comments on "Clinical utility of ultrasonography imaging in musculoskeletal conditions: a systematic review and meta-analysis"
    Chang, Ke-Vin
    Wu, Wei-Ting
    JOURNAL OF MEDICAL ULTRASONICS, 2022, 49 (01) : 117 - 118
  • [49] Diagnostic accuracy of cervical elastography for predicting preterm delivery: Systematic review and meta-analysis
    Sun, Hui
    Lv, Qifeng
    Liu, Tingting
    Zhang, Nan
    Shi, Fengfeng
    SCOTTISH MEDICAL JOURNAL, 2023, 68 (03) : 110 - 120
  • [50] Comments on “Clinical utility of ultrasonography imaging in musculoskeletal conditions: a systematic review and meta-analysis”
    Ke-Vin Chang
    Wei-Ting Wu
    Journal of Medical Ultrasonics, 2022, 49 : 117 - 118