Diagnostic utility of endoscopic ultrasonography-elastography in the evaluation of solid pancreatic masses: a meta-analysis and systematic review

被引:27
|
作者
Lu, Yi [1 ]
Chen, Lu [2 ]
Li, Chujun [1 ]
Chen, Honglei [1 ]
Chen, Jinhua [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 6, Digest Endoscopy Ctr, 26 Yuancun Erheng Rd, Guangzhou 510655, Guangdong, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Dept Gastroenterol, Ruijin Hosp,Digest Endoscopy Ctr, Shanghai, Peoples R China
关键词
endoscopic ultrasonography; elastography; contrast-enhanced EUS; EUS-guided fine needle aspiration; pancreatic masses; REAL-TIME ELASTOGRAPHY; ULTRASOUND-ELASTOGRAPHY; EUS-ELASTOGRAPHY; DIFFERENTIAL-DIAGNOSIS; STRAIN RATIO; LESIONS; ACCURACY; FNA; MULTICENTER; ADENOCARCINOMA;
D O I
10.11152/mu-987
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: The accuracy for endoscopic ultrasonography-elastography ( EUS-EG) in the evaluation of solid pancreatic masses varies greatly and the pooled results have not been updated since 2013. Also, there still lack a comprehensive comparison among EUS-EG, contrast-enhanced EUS (CE-EUS), and EUS-guided fine needle aspiration (EUS-FNA). Material and methods: A thorough search was made for diagnostic trials investigating the role of EUS-EG in solid pancreatic masses. Meta-Disc was used to calculate the pooled sensitivity, specificity, diagnostic odds ratio and summary receiver operator characteristics. Results: Finally, 17 studies (1537 patients, 1544 lesions) were selected. The pooled sensitivity and specificity for qualitative methods were 0.97 (95% CI, 0.95-0.99) and 0.67 (95% CI, 0.59-0.74), respectively; the pooled sensitivity and specificity for strain histograms were 0.97 (95% CI, 0.95-0.98) and 0.67(95% CI, 0.61-0.73), respectively; the pooled sensitivity and specificity for strain ratio were 0.98 (95% CI, 0.96-0.99) and 0.62 (95% CI, 0.56-0.68), respectively; the pooled sensitivity and specificity for CE-EUS were 0.90 (95% CI, 0.83-0.95) and 0.76 (95% CI, 0.67-0.84), respectively; the pooled sensitivity and specificity for EUS-FNA were 0.84 (95% CI, 0.77-0.90) and 0.96(95% CI, 0.88-1.00), respectively. Conclusion: EUS-EG is reliable for distinguishing solid pancreatic masses; the sensitivity and specificity for different diagnostic methods were very close. Both EUS-EG and CE-EUS can be valuable complementary supplements for EUS-FNA.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 50 条
  • [21] Endoscopic ultrasound elastography for differentiating between pancreatic adenocarcinoma and inflammatory masses: A meta-analysis
    Li, Xiang
    Xu, Wei
    Shi, Jian
    Lin, Yong
    Zeng, Xin
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (37) : 6284 - 6291
  • [22] Accuracy of Endoscopic Elastography for Detection of Malignant Pancreatic Mass Lesions. Systematic Review and Meta-Analysis
    Andrawes, Sherif A.
    Hindy, Pierre
    Taur, Ying
    Anand, Naveen
    Deeb, Liliane S.
    Gress, Frank G.
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 207 - 207
  • [23] Accuracy of Endoscopic Ultrasound in Detecting Solid Pancreatic Mass: A Meta-Analysis and Systematic Review
    Puli, Srinivas
    Bechtold, Matthew
    Szary, Nicholas
    Eloubeidi, Mohamad
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2009, 104 : S74 - S75
  • [24] DIAGNOSTIC UTILITY OF ENDOSCOPIC DUODENAL BULB BIOPSY FOR CELIAC DISEASE: A SYSTEMATIC REVIEW AND META-ANALYSIS
    McCarty, Thomas R.
    Gremida, Anas
    Ling, Christina
    O'Brien, Corey R.
    Rustagi, Tarun
    GASTROENTEROLOGY, 2018, 154 (06) : S680 - S680
  • [25] Diagnostic value of endoscopic ultrasound for detecting pancreatic neuroendocrine tumors: A systematic review and meta-analysis
    Chen, Yang
    Huang, Fei
    Fan, Youwen
    Li, Dong
    Tao, Qiang
    Tang, Di
    Deng, Liang
    Ma, Chao
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2022, 363 (06): : 511 - 518
  • [26] COMPARATIVE DIAGNOSTIC PERFORMANCE OF DIFFERENT TECHNIQUES FOR ENDOSCOPIC ULTRASOUND-GUIDED FINE-NEEDLE BIOPSY OF SOLID PANCREATIC MASSES: A SYSTEMATIC REVIEW AND NETWORK META-ANALYSIS
    Ramai, Daryl
    Facciorusso, Antonio
    Crino, Stefano Francesco
    Madhu, Deepak
    Fugazza, Alessandro
    Carrara, Silvia
    Spadaccini, Marco
    Mangiavillano, Benedetto
    Gkolfakis, Paraskevas
    Mohan, Babu
    Hassan, Cesare
    Repici, Alessandro
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (06) : AB829 - AB829
  • [27] Diagnostic performance of radiomics in adrenal masses: A systematic review and meta-analysis
    Zhang, Hao
    Lei, Hanqi
    Pang, Jun
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [28] Diagnostic value of routine ultrasonography combined with ultrasound elastography for papillary thyroid microcarcinoma A protocol for systematic review and meta-analysis
    Du, Yanfei
    Jiang, Yuyan
    Tang, Shujuan
    Li, Lijie
    MEDICINE, 2021, 100 (04)
  • [29] Clinical utility of ultrasonography imaging in musculoskeletal conditions: A Systematic review and Meta-analysis
    Summaiya Zareen Shaikh
    Dabholkar Tejashree
    Dabholkar Ajit
    Journal of Medical Ultrasonics, 2021, 48 : 285 - 294
  • [30] Clinical utility of ultrasonography imaging in musculoskeletal conditions: A Systematic review and Meta-analysis
    Shaikh, Summaiya Zareen
    Tejashree, Dabholkar
    Ajit, Dabholkar
    JOURNAL OF MEDICAL ULTRASONICS, 2021, 48 (03) : 285 - 294