A compact low jitter high power repetitive long-pulse relativistic electron beam source

被引:13
|
作者
Song, Falun [1 ]
Li, Fei [1 ]
Zhang, Beizhen [1 ]
Gong, Haitao [1 ]
Gan, Yanqing [1 ]
Jin, Xiao [1 ]
机构
[1] China Acad Engn Phys, Inst Appl Elect, Sci & Technol High Power Microwave Lab, Mianyang 621900, Peoples R China
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2019年 / 919卷
关键词
High power pulsed power technology; Relativistic electron beam; Repetition rate; Low jitter; SYSTEM;
D O I
10.1016/j.nima.2018.11.130
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A compact low jitter high power repetitive long-pulse relativistic electron beam source with novel circuit structure and mechanical structure is presented. Based on Marx type circuit and direct-drive idea, the key technologies such as high energy density pulse forming network, repetitive high voltage pulse generator and low jitter electrical trigger technology are developed. The volume and weight of the pulsed electron beam source are reduced remarkably by using two-capacitor pulse forming modules, alternating superposition structure on both sides and high electric field shielding technology. The key technical parameters of the electron beam source design include a peak output voltage 1 MV with peak current 20 kA. The impulse is 180 ns and has a repetition frequency 1 similar to 50 Hz, however, the output power and repetition frequency are able to be adjusted within a certain operating range. The machine has a total volume of 2.5 m(3) and weighs 2.2 tons, making it much more compact than conventional electron beam sources. The experimental results show that when the e-beam source is operated under a single pulse condition, the output voltage, current, and power are 0.98 MV, 19.6 kA, and 19.2 GW, respectively. When the e-beam source has a continuous operating time of 10 s at a repetition frequency of 30 Hz and an output power of 16.7 GW, the voltage fluctuation range is limited to within +/- 1.5%, and the current fluctuation range is limited to within +/- 2%. The delay time jitter between the trigger pulse and the output pulse is limited less than 6.5 ns standard mean deviation. Statistical distributions of the delay time jitter and current amplitude variation of the 300 pulses are approximately Gaussian. When the cooling system is working, the electron beam source can work continuously for 100 s under the conditions of an output power of 16.7 GW and repetition frequency of 30 Hz, and the system operation is stable and reliable.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 50 条
  • [41] TRANSVERSE OSCILLATIONS OF A LONG-PULSE ELECTRON-BEAM ON A LASER-FORMED CHANNEL
    SMITH, JR
    SHOKAIR, IR
    STRUVE, KW
    SCHAMILOGLU, E
    WERNER, PW
    LIPINSKI, RJ
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1991, 19 (05) : 850 - 854
  • [42] LONG-PULSE ELECTRON-BEAM GENERATION FROM THE BACK-LIGHTED THYRATRON
    LIOU, RL
    HSU, TY
    GUNDERSEN, MA
    APPLIED PHYSICS LETTERS, 1992, 61 (22) : 2647 - 2649
  • [43] LONG-PULSE, LOW-VOLTAGE INFRARED FREE-ELECTRON LASER
    MANNHEIMER, WM
    FLIFLET, AW
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1994, 30 (01) : 185 - 193
  • [44] Development of negative ion extractor in the high-power and long-pulse negative ion source for fusion application
    Kashiwagi, M.
    Umeda, N.
    Tobari, H.
    Kojima, A.
    Yoshida, M.
    Taniguchi, M.
    Dairaku, M.
    Maejima, T.
    Yamanaka, H.
    Watanabe, K.
    Inoue, T.
    Hanada, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [45] Design of a water-cooled tube for high-power and long-pulse radio frequency ion source
    Gu, Yuming
    Wei, Jianglong
    Xie, Yahong
    Tao, Ling
    Li, Jun
    Jiang, Caichao
    Xu, Yongjian
    Xie, Yuanlai
    Hu, Chundong
    FUSION ENGINEERING AND DESIGN, 2018, 129 : 164 - 170
  • [46] A long pulse width and high extraction rate arc plasma electron beam source
    Gao, S.
    Chen, S. X.
    Chen, K.
    Ji, Z. C.
    Chen, J.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2017, 60 (05) : 705 - 709
  • [47] A long pulse width and high extraction rate arc plasma electron beam source
    S. Gao
    S. X. Chen
    K. Chen
    Z. C. Ji
    J. Chen
    Instruments and Experimental Techniques, 2017, 60 : 705 - 709
  • [48] Long-pulse power-supply system for EAST neutral-beam injectors
    刘智民
    蒋才超
    潘军军
    刘胜
    许永建
    陈世勇
    胡纯栋
    NBI Team
    Plasma Science and Technology, 2017, 19 (05) : 101 - 105
  • [49] Long-pulse power-supply system for EAST neutral-beam injectors
    Liu, Zhimin
    Jiang, Caichao
    Pan, Junjun
    Liu, Sheng
    Xu, Yongjian
    Chen, Shiyong
    Hu, Chundong
    PLASMA SCIENCE & TECHNOLOGY, 2017, 19 (05)
  • [50] Oversized Modified Bragg Cavities for High-Power Long-Pulse Subterahertz Free-Electron Lasers
    N.Yu. Peskov
    N. S. Ginzburg
    V.Yu. Zaslavsky
    S.Yu. Kornishin
    Radiophysics and Quantum Electronics, 2020, 63 : 440 - 448