A compact low jitter high power repetitive long-pulse relativistic electron beam source

被引:13
|
作者
Song, Falun [1 ]
Li, Fei [1 ]
Zhang, Beizhen [1 ]
Gong, Haitao [1 ]
Gan, Yanqing [1 ]
Jin, Xiao [1 ]
机构
[1] China Acad Engn Phys, Inst Appl Elect, Sci & Technol High Power Microwave Lab, Mianyang 621900, Peoples R China
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2019年 / 919卷
关键词
High power pulsed power technology; Relativistic electron beam; Repetition rate; Low jitter; SYSTEM;
D O I
10.1016/j.nima.2018.11.130
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A compact low jitter high power repetitive long-pulse relativistic electron beam source with novel circuit structure and mechanical structure is presented. Based on Marx type circuit and direct-drive idea, the key technologies such as high energy density pulse forming network, repetitive high voltage pulse generator and low jitter electrical trigger technology are developed. The volume and weight of the pulsed electron beam source are reduced remarkably by using two-capacitor pulse forming modules, alternating superposition structure on both sides and high electric field shielding technology. The key technical parameters of the electron beam source design include a peak output voltage 1 MV with peak current 20 kA. The impulse is 180 ns and has a repetition frequency 1 similar to 50 Hz, however, the output power and repetition frequency are able to be adjusted within a certain operating range. The machine has a total volume of 2.5 m(3) and weighs 2.2 tons, making it much more compact than conventional electron beam sources. The experimental results show that when the e-beam source is operated under a single pulse condition, the output voltage, current, and power are 0.98 MV, 19.6 kA, and 19.2 GW, respectively. When the e-beam source has a continuous operating time of 10 s at a repetition frequency of 30 Hz and an output power of 16.7 GW, the voltage fluctuation range is limited to within +/- 1.5%, and the current fluctuation range is limited to within +/- 2%. The delay time jitter between the trigger pulse and the output pulse is limited less than 6.5 ns standard mean deviation. Statistical distributions of the delay time jitter and current amplitude variation of the 300 pulses are approximately Gaussian. When the cooling system is working, the electron beam source can work continuously for 100 s under the conditions of an output power of 16.7 GW and repetition frequency of 30 Hz, and the system operation is stable and reliable.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 50 条
  • [31] HIGH-BRIGHTNESS, LONG-PULSE, ELECTRON-BEAM PRODUCTION WITH SC PHOTO-INJECTORS
    PAGANI, C
    MICHELATO, P
    SERAFINI, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 340 (01): : 17 - 25
  • [32] Studies of a high-efficiency, long-pulse relativistic backward wave oscillator
    Cao, Yibing
    Sun, Jun
    Song, Zhimin
    Fan, Zhiqiang
    Zhang, Pinzhu
    Wu, Ping
    PHYSICS OF PLASMAS, 2021, 28 (02)
  • [33] BEAM-BREAKUP GROWTH AND REDUCTION EXPERIMENTS IN LONG-PULSE ELECTRON-BEAM TRANSPORT
    MENGE, PR
    GILGENBACH, RM
    LAU, YY
    BOSCH, RA
    JOURNAL OF APPLIED PHYSICS, 1994, 75 (03) : 1258 - 1266
  • [34] MICROWAVE GROWTH FROM THE BEAM BREAKUP INSTABILITY IN LONG-PULSE ELECTRON-BEAM EXPERIMENTS
    MENGE, PR
    GILGENBACH, RM
    BOSCH, RA
    APPLIED PHYSICS LETTERS, 1992, 61 (06) : 642 - 644
  • [35] A High-Power High-Voltage Power Supply for Long-Pulse Applications
    Pokryvailo, Alex
    Carp, Costel
    Scapellati, Clifford
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (10) : 2604 - 2610
  • [36] Key issues for the filament-arc ion source of EAST neutral beam injector toward high-power and long-pulse operation
    Wei, Jianglong
    Xie, Yahong
    Liu, Sheng
    Liu, Zhimin
    Liang, Lizhen
    Jiang, Caichao
    Tao, Ling
    Xu, Yongjian
    Li, Jun
    Gu, Yuming
    Xie, Yuanlai
    Hu, Chundong
    PLASMA PHYSICS AND CONTROLLED FUSION, 2020, 62 (02)
  • [37] Thermal Properties of an Intense Relativistic Electron Beam Collector Under Repetitive Pulse Operation
    Xun, Tao
    Yang, Han-wu
    Zhang, Jun
    Zhang, Jian-de
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (06) : 957 - 962
  • [38] Discrete Frequency Hopping in Long-Pulse High-Power Gyrotrons
    Schlaich, A.
    Illy, S.
    Gantenbein, G.
    Thumm, M.
    Jelonnek, J.
    2015 40TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES (IRMMW-THZ), 2015,
  • [39] MHD ACTIVITY IN GOL-3 DURING INJECTION OF LONG-PULSE ELECTRON BEAM
    Sudnikov, A. V.
    Burdakov, A. V.
    Gavrilenko, D. E.
    Kandaurov, I. V.
    Kurkuchekov, V. V.
    Mekler, K. I.
    Rovenskikh, A. F.
    Polosatkin, S. V.
    Postupaev, V.
    Trunev, Yu. A.
    FUSION SCIENCE AND TECHNOLOGY, 2013, 63 (1T) : 250 - 252
  • [40] Compact high-power subnanosecond repetitive-pulse generators
    Yalandin, MI
    Shpak, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2001, 44 (03) : 285 - 310