Clinical Application of Dual-Energy Spectral Computed Tomography in Detecting Cholesterol Gallstones From Surrounding Bile

被引:43
|
作者
Yang, Chuang-bo [1 ]
Zhang, Shuang [2 ]
Jia, Yong-jun [1 ]
Duan, Hai-feng [1 ]
Ma, Guang-ming [1 ]
Zhang, Xi-rong [1 ]
Yu, Yong [1 ]
He, Tai-ping [1 ]
机构
[1] Shaanxi Univ Chinese Med, Affiliated Hosp, Dept Diagnost Radiol, Weiyang Western Rd 2, Xianyang 712000, Peoples R China
[2] Shaanxi Inst Int Trade & Commerce, Sch Med, Dept Basic Chem, Xian 712046, Shaanxi, Peoples R China
关键词
Tomography; X-ray computed; dual-energy CT; material decomposition; cholesterol gallstones; IN-VITRO; CT; CHOLEDOCHOLITHIASIS; EXPERIENCE; VIVO;
D O I
10.1016/j.acra.2016.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objective: This study aimed to investigate the clinical value of spectral computed tomography (CT) in the detection of cholesterol gallstones from surrounding bile. Materials and Methods: This study was approved by the institutional review board. The unenhanced spectral CT data of 24 patients who had surgically confirmed cholesterol gallstones were analyzed. Lipid concentrations and CT numbers were measured from fat based material decomposition image and virtual monochromatic image sets (40-140 keV), respectively. The difference in lipid concentration and CT number between cholesterol gallstones and the surrounding bile were statistically analyzed. Receiver operating characteristic analysis was applied to determine the diagnostic accuracy of using lipid concentration to differentiate cholesterol gallstones from bile. Results: Cholesterol gallstones were bright on fat-based material decomposition images yielding a 92% detection rate (22 of 24). The lipid concentrations (552.65 +/- 262.36 mg/mL), CT number at 40 keV (-31.57 +/- 16.88 HU) and 140 keV (24.30 +/- 5.85 HU) for the cholesterol gallstones were significantly different from those of bile (-13.94 +/- 105.12 mg/mL; 12.99 +/- 9.39 HU and 6.19 +/- 4.97 HU, respectively). Using 182.59 mg/mL as the threshold value for lipid concentration, one could obtain sensitivity of 95.5% and specificity of 100% with accuracy of 0:994 for differentiating cholesterol gallstones tom bile. Conclusions: Virtual monochromatic. spectral CT images at 40 keV and 140 keV provide significant CT number differences between, cholesterol gallstones and the surrounding bile. Spectral CT provides an excellent detection rate for cholesterol gallstones.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 50 条
  • [1] Application of Dual-Energy Spectral Computed Tomography to Thoracic Oncology Imaging
    Kim, Cherry
    Kim, Wooil
    Park, Sung-Joon
    Lee, Young Hen
    Hwang, Sung Ho
    Yong, Hwan Seok
    Oh, Yu-Whan
    Kang, Eun-Young
    Lee, Ki Yeol
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (07) : 838 - 850
  • [2] Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research
    Wang, Mingyue
    Wu, Yan
    Zhou, Yue
    Dong, Junqiang
    Hu, Shenshen
    Hou, Ping
    Gao, Jianbo
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2022, 15 : 6887 - 6896
  • [3] Principles and Clinical Application of Dual-energy Computed Tomography in the Evaluation of Cerebrovascular Disease
    Hsu, Charlie Chia-Tsong
    Kwan, Gigi Nga Chi
    Singh, Dalveer
    Pratap, Jit
    Watkins, Trevor William
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2016, 6
  • [4] Utility of Dual-Energy Computed Tomography in Clinical Conundra
    Abu-Omar, Ahmad
    Murray, Nicolas
    Ali, Ismail T.
    Khosa, Faisal
    Barrett, Sarah
    Sheikh, Adnan
    Nicolaou, Savvas
    Tamburrini, Stefania
    Iacobellis, Francesca
    Sica, Giacomo
    Granata, Vincenza
    Saba, Luca
    Masala, Salvatore
    Scaglione, Mariano
    DIAGNOSTICS, 2024, 14 (07)
  • [5] Clinical applications of dual-energy computed tomography in neuroradiology
    Tran, Ngoc-Anh
    Sodickson, Aaron D.
    Gupta, Rajiv
    Potter, Christopher A.
    SEMINARS IN ULTRASOUND CT AND MRI, 2022, 43 (04) : 280 - 292
  • [6] Clinical Applications of Dual-Energy Computed Tomography in the Liver
    Kim, Sooah
    Shuman, William P.
    SEMINARS IN ROENTGENOLOGY, 2016, 51 (04) : 284 - 291
  • [7] Detection of gallbladder stones by dual-energy spectral computed tomography imaging
    An-Liang Chen
    Ai-Lian Liu
    Sheng Wang
    Jing-Hong Liu
    Ye Ju
    Mei-Yu Sun
    Yi-Jun Liu
    World Journal of Gastroenterology, 2015, (34) : 9993 - 9998
  • [8] A comprehensive review of dual-energy and multi-spectral computed tomography
    Garnett, Richard
    CLINICAL IMAGING, 2020, 67 : 160 - 169
  • [9] Detection of gallbladder stones by dual-energy spectral computed tomography imaging
    Chen, An-Liang
    Liu, Ai-Lian
    Wang, Sheng
    Liu, Jing-Hong
    Ju, Ye
    Sun, Mei-Yu
    Liu, Yi-Jun
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (34) : 9993 - 9998
  • [10] Introduction to Dual-Energy Computed Tomography
    Elster, Allen D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 823 - 823