The use of a microbubble agent to enhance rabbit liver destruction using high intensity focused ultrasound

被引:40
|
作者
Yu, TH [1 ]
Xiong, SH
Mason, TJ
Wang, ZB
机构
[1] Chongqing Med Univ, Inst Ultrasound Engn Med, Chongqing 400016, Peoples R China
[2] Jiangxi Provincial Mat & Childrens Hosp, Dept Gynecol Oncol, Nanchang, Peoples R China
[3] Coventry Univ, Sch NES, Sonochem Ctr, Coventry CV1 5FB, W Midlands, England
关键词
high intensity focused ultrasound; ablation; microbubble agent; liver;
D O I
10.1016/j.ultsonch.2005.02.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Liver tissues in New Zealand rabbits were ablated using high intensity focused ultrasound (HIFU, 14300 W/cm(2), 1.0 MHz). The animals were intravenously administered 0.2 ml of microbubble agent in the experimental (n = 20) group and an isovolumetric normal saline solution in the control (n = 27) group before HIFU treatment which was performed as a linear scan. In both groups, the preselected tissue volumes were destroyed without harming the overlying tissues. Necrosis rate (NR, cm(3)/s) was used to reflect the ablation efficiency, which was the tissue volume of occurring coagulative necrosis per 1 s HIFU exposure. NR was improved in the experimental group (0.0570 +/- 0.0433 vs 0.0120 +/- 0.0122, P = 0.0002). Pathological studies confirmed that there were no residual intact targets within the exposed volume. These findings suggested that the introduction of the microbubble agent enhanced HIFU liver destruction. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [31] EFFECT OF MAGNETITE NANOPARTICLE AGGLOMERATES ON THE DESTRUCTION OF TUMOR SPHEROIDS USING HIGH INTENSITY FOCUSED ULTRASOUND
    Ho, Vincent H. B.
    Smith, Moira J.
    Slater, Nigel K. H.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (01): : 169 - 175
  • [32] Hemostasis using high intensity focused ultrasound
    Vaezy, Shahram
    Martin, Roy
    Mourad, Pierre
    Crum, Lawrence
    European Journal of Ultrasound, 1999, 9 (01): : 79 - 87
  • [33] Thrombolysis using high intensity focused ultrasound
    Fujikura, K
    Otsuka, R
    Abe, Y
    Kettering, JA
    Lizzi, FL
    Homma, S
    CIRCULATION, 2004, 110 (17) : 716 - 716
  • [34] Non-thermal ablation of rabbit liver VX2 tumor by pulsed high intensity focused ultrasound with ultrasound contrast agent:Pathological characteristics
    Cheng-Wen Zhou Xiao-Lin Zheng Bioengineering College
    State Key Laboratory of Ultrasound Engineering in Medicine Cofounded by Chongqing and MOST
    World Journal of Gastroenterology, 2008, 14 (43) : 6743 - 6747
  • [35] Non-thermal ablation of rabbit liver VX2 tumor by pulsed high intensity focused ultrasound with ultrasound contrast agent: Pathological characteristics
    Zhou, Cheng-Wen
    Li, Fa-Qi
    Qin, Yan
    Liu, Chun-Mei
    Zheng, Xiao-Lin
    Wang, Zhi-Biao
    WORLD JOURNAL OF GASTROENTEROLOGY, 2008, 14 (43) : 6743 - 6747
  • [36] Effect of Healthy Tissue Ablation Surrounding VX2 Rabbit Liver Tumors by High-Intensity Focused Ultrasound Combined With an Ultrasound Contrast Agent
    Fan, Zhiyong
    Luo, Wen
    Song, Zhenshun
    Zheng, Wei
    Hu, Haitian
    Du, Lixue
    Zhou, Xiaodong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (06) : 863 - 871
  • [37] Erythrocytes and microbubble contrast agents, improve the therapeutic efficiency of high intensity focused ultrasound
    Takegami, K
    Kaneko, Y
    Watanabe, T
    Maruyama, T
    Matsumoto, Y
    Nagawa, H
    4th International Symposium on Therapeutic Ultrasound, 2005, 754 : 217 - 219
  • [38] EFFECTS OF NON-FOCUSED MICROBUBBLE-ENHANCED AND HIGHINTENSITY FOCUSED ULTRASOUND ON HEMOSTASIS IN A RABBIT MODEL OF LIVER TRAUMA
    Zhao, Da-Wei
    Tian, Meng
    Zou, Jian-Zhong
    Zheng, Yuan-Yi
    Li, Tao
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (03): : 629 - 639
  • [39] Enhancement of ultrasound contrast agent in High-Intensity focused ultrasound ablation
    Wen Luo
    Xiaodong Zhou
    Xue Tian
    Xialong Ren
    Minjuan Zheng
    Kejun Gu
    Guangbin He
    Advances in Therapy, 2006, 23 : 861 - 868
  • [40] Enhancement of ultrasound contrast agent in high-intensity focused ultrasound ablation
    Luo, Wen
    Zhou, Xiaodong
    Tian, Xue
    Ren, Xialong
    Zheng, Minjuan
    Gu, Kejun
    He, Guangbin
    ADVANCES IN THERAPY, 2006, 23 (06) : 861 - 868