EFFECT OF MAGNETITE NANOPARTICLE AGGLOMERATES ON THE DESTRUCTION OF TUMOR SPHEROIDS USING HIGH INTENSITY FOCUSED ULTRASOUND

被引:38
|
作者
Ho, Vincent H. B. [1 ]
Smith, Moira J. [1 ]
Slater, Nigel K. H. [1 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge CB2 3RA, England
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2011年 / 37卷 / 01期
基金
英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
Magnetite nanoparticles; High-intensity focused ultrasound (HIFU); Inertial cavitation; Multicellular spheroids; Tumor ablation; ACOUSTIC CAVITATION; CONTRAST-AGENT; CELL-LYSIS; IN-VITRO; TISSUE; ENHANCEMENT; CULTURE; THERAPY;
D O I
10.1016/j.ultrasmedbio.2010.09.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Magnetite (Fe3O4) nanoparticle agglomerates have been shown to enhance the degree of inertial cavitation induced by high-intensity focused ultrasound (HIFU). To investigate the effect of these particles on the destruction of tumor spheroids using HIFU, HeLa spheroids were insonated in the presence and absence of magnetite nanoparticle agglomerates. The HIFU transducer was operated with a frequency of 1.1 MHz, pulse repetition frequency of 1.67 kHz, 5% and 50% duty cycles and peak negative focal pressure of 7.2 MPa for 10 s. The significant increase in the HIFU-induced inertial cavitation caused by the presence of magnetite particles at 50% duty cycle was sufficient to cause cell lysis and disintegrate the whole spheroid (p <= 0.001). This suggests that magnetite nanoparticle agglomerates can enhance the efficacy of HIFU in tumor ablation and other related therapies. (E-mail: nkhs2@cam.ac.uk) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 50 条
  • [1] EFFECT OF MAGNETITE NANOPARTICLE AGGLOMERATES ON ULTRASOUND INDUCED INERTIAL CAVITATION
    Smith, Moira J.
    Ho, Vincent H. B.
    Darton, Nicholas J.
    Slater, Nigel K. H.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (06): : 1010 - 1014
  • [2] THE DESTRUCTION OF ESCHERICHIA COLI BIOFILMS USING HIGH-INTENSITY FOCUSED ULTRASOUND
    Bigelow, Timothy A.
    Northagen, Trevor
    Hill, Thomas M.
    Sailer, Frances C.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (06): : 1026 - 1031
  • [3] LOCALIZED TISSUE DESTRUCTION BY HIGH-INTENSITY FOCUSED ULTRASOUND
    LINKE, CA
    CARSTENSEN, EL
    FRIZZELL, LA
    ELBADAWI, A
    FRIDD, CW
    ARCHIVES OF SURGERY, 1973, 107 (06) : 887 - 891
  • [4] Tumor vessel destruction resulting from high-intensity focused ultrasound in patients with solid malignancies
    Wu, F
    Chen, WZ
    Bai, J
    Zou, JZ
    Wang, ZL
    Zhu, H
    Wang, ZB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (04): : 535 - 542
  • [5] High intensity focused ultrasound in clinical tumor ablation
    Zhou, Yu-Feng
    WORLD JOURNAL OF CLINICAL ONCOLOGY, 2011, 2 (01): : 8 - 27
  • [6] High-Intensity Focused Ultrasound: Heating and Destruction of Biological Tissue
    T. A. Andreeva
    A. E. Berkovich
    N. Y. Bykov
    S. V. Kozyrev
    A. Ya. Lukin
    Technical Physics, 2020, 65 : 1455 - 1466
  • [7] High-Intensity Focused Ultrasound: Heating and Destruction of Biological Tissue
    Andreeva, T. A.
    Berkovich, A. E.
    Bykov, N. Y.
    Kozyrev, S. V.
    Lukin, A. Ya.
    TECHNICAL PHYSICS, 2020, 65 (09) : 1455 - 1466
  • [8] The use of a microbubble agent to enhance rabbit liver destruction using high intensity focused ultrasound
    Yu, TH
    Xiong, SH
    Mason, TJ
    Wang, ZB
    ULTRASONICS SONOCHEMISTRY, 2006, 13 (02) : 143 - 149
  • [9] Hemostasis using high intensity focused ultrasound
    Vaezy, Shahram
    Martin, Roy
    Mourad, Pierre
    Crum, Lawrence
    European Journal of Ultrasound, 1999, 9 (01): : 79 - 87
  • [10] Thrombolysis using high intensity focused ultrasound
    Fujikura, K
    Otsuka, R
    Abe, Y
    Kettering, JA
    Lizzi, FL
    Homma, S
    CIRCULATION, 2004, 110 (17) : 716 - 716