Performance Estimation of a Remote Field Eddy Current Method for the Inspection of Water Distribution Pipes

被引:6
|
作者
Duchesne, Sophie [1 ]
Bouzida, Nabila [1 ]
Villeneuve, Jean-Pierre [1 ]
机构
[1] Ctr Eau Terre Environm, Inst Natl Rech Sci, Quebec City, PQ G1K 9A9, Canada
关键词
Cast iron; Corrosion; Imaging techniques; Inspection; Magnetic fields; Pipe networks; Radiography; Water distribution systems; COMPUTED-TOMOGRAPHY; REPLACEMENT; DENSITY;
D O I
10.1061/(ASCE)WR.1943-5452.0000136
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Remote Field Eddy Current (RFEC) technology allows the in situ inspection of metallic water distribution pipes. RFEC tools provide the location and magnitude of corrosion defects on the inspected pipes. The capacity of an RFEC tool to detect corrosion defects is evaluated in this paper by comparing its results with those obtained from the analysis of computed tomography (CT) scan images of the inspected pipes. Localization and characteristics of defects identified with the RFEC tool and from the CT scan images were compared for six cast iron pipes. An original method is proposed for the analysis of the CT scan images from which wall thickness losses were estimated by using the basic principle that the attenuation coefficient of X-rays in a homogenous material is a linear function of its density. The results show that the RFEC tool is able to localize most of the defects identified from the analysis of CT scan images. These findings reveal that the tested RFEC probe provided reliable information on the main corrosion defects, and thus on the general structural integrity of the inspected pipes. DOI: 10.1061/(ASCE)WR.1943-5452.0000136. (C) 2011 American Society of Civil Engineers.
引用
收藏
页码:521 / 530
页数:10
相关论文
共 50 条
  • [41] Performance improvement methods used for remote field eddy current sensor
    Xu Xiaojie
    Luo Feilu
    Pan MengChun
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 712 - 716
  • [42] Expanding the remote field eddy current techniques to thick-walled aluminum plate inspection
    Sun, YS
    Lord, W
    Udpa, L
    Udpa, S
    Lua, SK
    Ng, KH
    Nath, S
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION, 1997, 12 : 145 - 152
  • [43] MODERN CORROSION INSPECTION FOR FERROMAGNETIC TUBE MATERIAL WITH REMOTE FIELD EDDY-CURRENT TECHNIQUE
    KELB, W
    WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1995, 46 (08): : 481 - 487
  • [44] A study of the extent that support plates affect the accuracy of results of remote field eddy current inspection
    Jeng, J.-J.
    Wu, S.-J.
    Insight: Non-Destructive Testing and Condition Monitoring, 2002, 44 (02): : 104 - 108
  • [45] A novel remote field eddy current technique for inspection of thick-walled aluminum plates
    Sun, YS
    Udpa, L
    Udpa, S
    Lord, W
    Nath, S
    Lua, SK
    Ng, KH
    MATERIALS EVALUATION, 1998, 56 (01) : 94 - 97
  • [46] Thick-walled aluminum plate inspection using remote field eddy current techniques
    Sun, YS
    Lord, W
    Udpa, L
    Udpa, S
    Lua, SK
    Ng, KH
    Nath, S
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 16A AND 16B, 1997, 16 : 1005 - 1012
  • [47] REMOTE-FIELD EDDY CURRENT INSPECTION TOOL FOR SMALL-DIAMETER UNPIGGABLE PIPELINES
    Burkhardt, Gary L.
    Goyen, Todd H.
    Parvin, Albert J.
    Peterson, Ronald H.
    Tennis, Richard F.
    IPC2008: PROCEEDINGS OF THE ASME INTERNATIONAL PIPELINE CONFERENCE - 2008, VOL 2, 2009, : 41 - 44
  • [48] Study on the appropriate exciter-to-detector distance in remote field eddy current tubing inspection
    Hoshikawa, H
    Koyama, K
    Hayakawa, H
    Morisaki, H
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (IV), 2000, 17 : 71 - 78
  • [49] A study of the extent that support plates affect the accuracy of results of remote field eddy current inspection
    Jeng, JJ
    Wu, SJ
    INSIGHT, 2002, 44 (02) : 104 - 108
  • [50] Inspection of Tubes by the Eddy Current Method.
    Stumm, Wolfgang
    Baender Bleche Rohre, 1981, 22 (02): : 27 - 30