Remote Field Eddy Current (RFEC) technology allows the in situ inspection of metallic water distribution pipes. RFEC tools provide the location and magnitude of corrosion defects on the inspected pipes. The capacity of an RFEC tool to detect corrosion defects is evaluated in this paper by comparing its results with those obtained from the analysis of computed tomography (CT) scan images of the inspected pipes. Localization and characteristics of defects identified with the RFEC tool and from the CT scan images were compared for six cast iron pipes. An original method is proposed for the analysis of the CT scan images from which wall thickness losses were estimated by using the basic principle that the attenuation coefficient of X-rays in a homogenous material is a linear function of its density. The results show that the RFEC tool is able to localize most of the defects identified from the analysis of CT scan images. These findings reveal that the tested RFEC probe provided reliable information on the main corrosion defects, and thus on the general structural integrity of the inspected pipes. DOI: 10.1061/(ASCE)WR.1943-5452.0000136. (C) 2011 American Society of Civil Engineers.
引用
收藏
页码:521 / 530
页数:10
相关论文
共 50 条
  • [31] Magnetic field shielding technique for pulsed remote field eddy current inspection of planar conductors
    Yang, Binfeng
    Xu, Junmin
    Wu, Hao
    He, Yunze
    NDT & E INTERNATIONAL, 2017, 90 : 48 - 54
  • [32] Feature analysis and processing of pulsed remote field eddy current signal in oil pipes
    Zhang W.
    Li Y.
    Shi Y.
    Luo Q.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (01): : 12 - 20
  • [33] Modern corrosion inspection for ferromagnetic tube material with remote field eddy current technique
    Kelb, W.
    Werkstoffe und Korrosion, 1995, 46 (08): : 481 - 487
  • [34] Pulsed remote eddy current field array technique for nondestructive inspection of ferromagnetic tube
    Yang, Binfeng
    Li, Xuechao
    NONDESTRUCTIVE TESTING AND EVALUATION, 2010, 25 (01) : 3 - 12
  • [35] Remote field eddy current technique applied to the inspection of nonmagnetic steam generator tubes
    Shin, YK
    Chung, TE
    Lord, W
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 20A AND 20B, 2001, 557 : 392 - 399
  • [36] Inspection of metallic plates using a novel remote field eddy current NDT probe
    Sun, YS
    Udpa, S
    Lord, W
    Cooley, D
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 1137 - 1144
  • [37] Remote field eddy current inspection for groove sizing choice of a direct model structure
    Fleury, G
    Davoust, ME
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 19A AND 19B, 2000, 509 : 541 - 548
  • [38] Optimal design of remote field eddy current testing probe for ferromagnetic pipeline inspection
    She, Saibo
    Chen, Yifang
    He, Yunze
    Zhou, Zhongji
    Zou, Xiang
    MEASUREMENT, 2021, 168
  • [39] Pipes control by eddy-current method using the rotating magnetic field
    Grimberg, R
    Mihalache, O
    Savin, A
    Radu, E
    4TH INTERNATIONAL CONFERENCE OF SLOVENIAN SOCIETY FOR NONDESTRUCTIVE TESTING - APPLICATION OF CONTEMPORARY NONDESTRUCTIVE TESTING IN ENGINEERING, CONFERENCE PROCEEDINGS, 1997, : 377 - 377
  • [40] Approach for removing ghost-images in remote field eddy current testing of ferromagnetic pipes
    Luo, Q. W.
    Shi, Y. B.
    Wang, Z. G.
    Zhang, W.
    Zhang, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (10):