An optimized quadrature RF receive coil for very-low-field (50.4 mT) magnetic resonance brain imaging

被引:11
|
作者
Shen, Sheng [1 ]
Kong, Xiaohan [1 ]
Meng, Fanqin [1 ]
Wu, Jiamin [2 ,3 ]
He, Yucheng [2 ]
Guo, Pan [4 ]
Xu, Zheng [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] Shenzhen Acad Aerosp Technol, 6 Keji South 10th Rd,C4, Shenzhen 518057, Peoples R China
[3] Harbin Inst Technol, 92 Xi Da Zhi Jie, Harbin 150001, Nangang Qu, Peoples R China
[4] Chongqing Normal Univ, Sch Phys & Elect Engn, Chongqing 401331, Peoples R China
基金
中国国家自然科学基金;
关键词
Very-low-field MRI; Quadrature RF coil; RF coil optimization; BODY MRI; DESIGN;
D O I
10.1016/j.jmr.2022.107269
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The radiofrequency (RF) receive coil is a direct probe for magnetic resonance imaging (MRI), and its performance determines the quality of MRI results. The RF coil employed for low-field MRI has a low working frequency, which makes its characteristic different from the RF coil exploited for conventional clinic MRI and may result in a different optimum RF coil configuration. To design and optimize a head RF receive coil for a very-low-field (50.4 mT) MRI system, we investigated the relationship between the structure and performance of the RF coil. Specifically, we focused on a quadrature RF coil consisting of a saddle coil and a modified Helmholtz coil wound around the surface of an elliptical cylinder. First, we evaluated the efficiency and RF magnetic field inhomogeneity of one-loop RF coil and determined the optimum dimension for saddle coil and modified Helmholtz RF coil. Then, we further studied the performance of the optimum-dimension RF coil from the perspective of the number of RF coil loops and revealed that the number of loops of RF coil for very-low-field MRI was a remarkable feature influencing the alternative current (AC) resistance of the RF coil and therefore make the SNR increase first and then decrease with the number of RF coil loops. We finally obtained the optimum number of loops for the saddle coil, modified Helmholtz coil, and fabricated a quadrature RF coil. The performance of the quadrature coil was evaluated through CuSO4 phantom imaging and in vivo human brain imaging. In phantom imaging, the SNR of quadrature RF coil increased by about 40% compared with that of single-channel RF coil.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Approaches in cooling of resistive coil-based low-field Magnetic Resonance Imaging (MRI) systems for application in low resource settings
    Faith Natukunda
    Theodora M. Twongyirwe
    Steven J. Schiff
    Johnes Obungoloch
    BMC Biomedical Engineering, 3 (1):
  • [42] Enhancing Whole-Brain Magnetic Field Homogeneity for 3D-Magnetic Resonance Spectroscopic Imaging with a Novel Unified Coil: A Preliminary Study
    Malagi, Archana Vadiraj
    Li, Xinqi
    Zhang, Na
    Liu, Yucen
    Huang, Yuheng
    Serry, Fardad Michael
    Long, Ziyang
    Yang, Chia-Chi
    Shan, Yujie
    Cai, Yubin
    Zepeda, Jeremy
    Binesh, Nader
    Li, Debiao
    Yang, Hsin-Jung
    Han, Hui
    CANCERS, 2024, 16 (06)
  • [43] A birdcage transmit, 24-channel conformal receive array coil for sensitive 31P magnetic resonance spectroscopic imaging of the human brain at 7 T
    Hovagimian, Johnny Der
    Yazdanbakhsh, Pedram
    Halilibrahimoglu, Hande
    Couch, Marcus J.
    Hoge, Richard
    Rudko, David A.
    NMR IN BIOMEDICINE, 2024, 37 (10)
  • [44] Low-Field Portable Magnetic Resonance Imaging for Post-Thrombectomy Assessment of Ongoing Brain Injury
    Sujijantarat, Nanthiya
    Koo, Andrew B.
    Jambor, Ivan
    Malhotra, Ajay
    Mazurek, Mercy H.
    Parasuram, Nethra
    Yadlapalli, Vineetha
    Chavva, Isha R.
    Lalwani, Dheeraj
    Zabinska, Julia
    Roy, Joanna M.
    Antonios, Joseph P.
    Elsamadicy, Aladine A.
    Renedo, Daniela
    Hebert, Ryan M.
    Schindler, Joseph L.
    Gilmore, Emily J.
    Sansing, Lauren H.
    de Havenon, Adam
    Olexa, Madelynne
    Schiff, Steven J.
    Iglesias, Juan Eugenio
    Rosen, Matthew
    Kimberly, William Taylor
    Petersen, Nils H.
    Sheth, Kevin N.
    Matouk, Charles C.
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (05):
  • [45] Proof of concept: Portable ultra-low-field magnetic resonance imaging for the diagnosis of epileptogenic brain pathologies
    Bauer, Tobias
    Olbrich, Simon
    Groteklaes, Anne
    Lehnen, Nils Christian
    Zidan, Mousa
    Lange, Annalena
    Bisten, Justus
    Walger, Lennart
    Faber, Jennifer
    Bruchhausen, Walter
    Vollmuth, Philipp
    Herrlinger, Ulrich
    Radbruch, Alexander
    Surges, Rainer
    Sabir, Hemmen
    Rueber, Theodor
    EPILEPSIA, 2024, 65 (12) : 3607 - 3618
  • [46] Iron oxide nanoparticles as positive T1 contrast agents for low-field magnetic resonance imaging at 64 mT
    Oberdick, Samuel D. D.
    Jordanova, Kalina V. V.
    Lundstrom, John T. T.
    Parigi, Giacomo
    Poorman, Megan E. E.
    Zabow, Gary
    Keenan, Kathryn E. E.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [47] Iron oxide nanoparticles as positive T1 contrast agents for low-field magnetic resonance imaging at 64 mT
    Samuel D. Oberdick
    Kalina V. Jordanova
    John T. Lundstrom
    Giacomo Parigi
    Megan E. Poorman
    Gary Zabow
    Kathryn E. Keenan
    Scientific Reports, 13
  • [48] Brain and Ventricles in Very Low Birth Weight Infants at Term: A Comparison Among Head Circumference, Ultrasound, and Magnetic Resonance Imaging
    Maunu, Jonna
    Parkkola, Riitta
    Rikalainen, Hellevi
    Lehtonen, Liisa
    Haataja, Leena
    Lapinleimu, Helena
    PEDIATRICS, 2009, 123 (02) : 617 - 626
  • [49] 572 Routine Magnetic Resonance Imaging of the Brain at Term Corrected Age in All Our Very Low Birth Weight Infants
    B Geier
    S Otto
    N Utzig
    R Stenger
    M Zygmunt
    C Fusch
    N Hosten
    Pediatric Research, 2010, 68 : 293 - 293
  • [50] Low field strength magnetic resonance imaging of the neonatal brain (vol 88, pg F203, 2003)
    Whitby
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2004, 89 (01): : F40 - F40