An optimized quadrature RF receive coil for very-low-field (50.4 mT) magnetic resonance brain imaging

被引:11
|
作者
Shen, Sheng [1 ]
Kong, Xiaohan [1 ]
Meng, Fanqin [1 ]
Wu, Jiamin [2 ,3 ]
He, Yucheng [2 ]
Guo, Pan [4 ]
Xu, Zheng [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] Shenzhen Acad Aerosp Technol, 6 Keji South 10th Rd,C4, Shenzhen 518057, Peoples R China
[3] Harbin Inst Technol, 92 Xi Da Zhi Jie, Harbin 150001, Nangang Qu, Peoples R China
[4] Chongqing Normal Univ, Sch Phys & Elect Engn, Chongqing 401331, Peoples R China
基金
中国国家自然科学基金;
关键词
Very-low-field MRI; Quadrature RF coil; RF coil optimization; BODY MRI; DESIGN;
D O I
10.1016/j.jmr.2022.107269
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The radiofrequency (RF) receive coil is a direct probe for magnetic resonance imaging (MRI), and its performance determines the quality of MRI results. The RF coil employed for low-field MRI has a low working frequency, which makes its characteristic different from the RF coil exploited for conventional clinic MRI and may result in a different optimum RF coil configuration. To design and optimize a head RF receive coil for a very-low-field (50.4 mT) MRI system, we investigated the relationship between the structure and performance of the RF coil. Specifically, we focused on a quadrature RF coil consisting of a saddle coil and a modified Helmholtz coil wound around the surface of an elliptical cylinder. First, we evaluated the efficiency and RF magnetic field inhomogeneity of one-loop RF coil and determined the optimum dimension for saddle coil and modified Helmholtz RF coil. Then, we further studied the performance of the optimum-dimension RF coil from the perspective of the number of RF coil loops and revealed that the number of loops of RF coil for very-low-field MRI was a remarkable feature influencing the alternative current (AC) resistance of the RF coil and therefore make the SNR increase first and then decrease with the number of RF coil loops. We finally obtained the optimum number of loops for the saddle coil, modified Helmholtz coil, and fabricated a quadrature RF coil. The performance of the quadrature coil was evaluated through CuSO4 phantom imaging and in vivo human brain imaging. In phantom imaging, the SNR of quadrature RF coil increased by about 40% compared with that of single-channel RF coil.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] ROUTINE MAGNETIC RESONANCE IMAGING OF THE NEONATAL BRAIN AT TERM IN ALL OUR VERY LOW BIRTH WEIGHT INFANTS
    Geier, B.
    Langner, S.
    Hosten, N.
    Fusch, C.
    ACTA PAEDIATRICA, 2009, 98 : 141 - 142
  • [32] Fast Room Temperature Very Low Field-Magnetic Resonance Imaging System Compatible with MagnetoEncephaloGraphy Environment
    Galante, Angelo
    Sinibaldi, Raffaele
    Conti, Allegra
    De Luca, Cinzia
    Catallo, Nadia
    Sebastiani, Piero
    Pizzella, Vittorio
    Romani, Gian Luca
    Sotgiu, Antonello
    Della Penna, Stefania
    PLOS ONE, 2015, 10 (12):
  • [33] High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil
    Savukov, Igor
    Kim, Young Jin
    Newman, Shaun
    JOURNAL OF APPLIED PHYSICS, 2022, 132 (17)
  • [34] Compact metamaterial-inspired RF coil based on split-ring resonators to enhance the magnetic field for 1.5T magnetic resonance imaging
    Kong, Xiangzheng
    Xiao, Xia
    Liu, Yu
    Pang, Yanwei
    OPTICS COMMUNICATIONS, 2024, 556
  • [35] OPTIMIZING TECHNICAL CONDITIONS FOR MAGNETIC-RESONANCE-IMAGING OF THE RAT-BRAIN AND ABDOMEN IN A LOW MAGNETIC-FIELD
    YAMADA, K
    MIYAHARA, K
    SATO, M
    HIROSE, T
    YASUGI, Y
    MATSUDA, Y
    FURUHAMA, K
    VETERINARY RADIOLOGY & ULTRASOUND, 1995, 36 (06) : 523 - 527
  • [36] Low-field magnetic resonance imaging of a pyocephalus and a suspected brain abscess in a German Shepherd dog
    Seiler, G
    Cizinauskas, S
    Scheidegger, M
    Lang, J
    VETERINARY RADIOLOGY & ULTRASOUND, 2001, 42 (05) : 417 - 422
  • [37] Low field intra-operative magnetic resonance imaging for brain tumour surgery: preliminary experience
    Roldan, Pedro
    Garcia, Sergio
    Gonzalez, Josep
    Alberto Reyes, Luis
    Torales, Jorge
    Valero, Ricard
    Oleaga, Laura
    Ensenat, Joaquim
    NEUROCIRUGIA, 2017, 28 (03): : 103 - 110
  • [38] THE INVESTIGATION OF BRAIN-STEM GLIOMAS USING LOW-FIELD MAGNETIC-RESONANCE-IMAGING
    KEAN, DM
    SELLAR, RJ
    DOUGLAS, RHB
    SMITH, MA
    BEST, JJK
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 817 - 817
  • [39] ROUTINE MAGNETIC RESONANCE IMAGING OF THE BRAIN AT TERM CORRECTED AGE IN ALL OUR VERY LOW BIRTH WEIGHT INFANTS
    Geier, B.
    Otto, S.
    Utzig, N.
    Stenger, R.
    Zygmunt, M.
    Fusch, C.
    Hosten, N.
    PEDIATRIC RESEARCH, 2010, 68 : 293 - 293
  • [40] Swaddling Technique for Alternative to Sedative Administration during Brain Magnetic Resonance Imaging in Very Low Birth Weight Infants
    Yoo, Yeong Myong
    Park, Hye Jung
    Park, Moon Sung
    Lee, Jang Hoon
    EUROPEAN JOURNAL OF PEDIATRICS, 2019, 178 (11) : 1752 - 1752