Microbiological Quality of Water Immersion-Chilled and Air-Chilled Broilers

被引:26
|
作者
Zhang, Lei [1 ]
Jeong, Jong Y. [1 ]
Janardhanan, Kishorekumar K. [1 ]
Ryser, Elliot T. [2 ]
Kang, Iksoon [1 ,2 ]
机构
[1] Michigan State Univ, Dept Anim Sci, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Food Sci & Human Nutr, E Lansing, MI 48824 USA
关键词
CROSS-CONTAMINATION; CAMPYLOBACTER-JEJUNI; LISTERIA-MONOCYTOGENES; MOISTURE RETENTION; BACTERIAL COUNTS; POULTRY MEAT; CARCASSES; SALMONELLA; PROFILE; FRANKFURTERS;
D O I
10.4315/0362-028X.JFP-11-032
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Carcass chilling during broiler processing is a critical step in preventing growth of pathogenic and spoilage bacteria. The objective of this study was to compare the microbiological quality of air- and water-chilled broiler carcasses processed at the same commercial facility. For each of four replications, 15 broilers were collected from the same commercial processing line after evisceration, after spraying with cetylpyridinium chloride (a cationic disinfectant), and after air chilling or water immersion chilling (WIC). All carcasses were quantitatively examined for mesophilic aerobic bacteria, Escherichia coli, coliforms, and Campylobacter as well as for the presence of Salmonella and Campylobacter. No significant differences (P > 0.05) were seen between air and water chilling for E. coli or coliforms or for the incidence of Salmonella and Campylohacter. Lower numbers of Campylobacter were recovered from WIC than from air-chilled carcasses (P < 0.05), but the incidence of Campylobacter on WIC carcasses was similar, suggesting that some Campylobacter organisms were injured rather than killed during WIC. In-line spraying with the disinfectant effectively decreased the incidence of Salmonella and Campylobacter on prechilled carcasses; however, cells presumably injured by the sanitizer recovered during chilling. Therefore, on-farm intervention strategies remain critically important in minimizing the spread of microbial contaminants during processing.
引用
收藏
页码:1531 / 1535
页数:5
相关论文
共 50 条
  • [21] Microbiological quality of chilled beef carcasses in northern Ireland: A baseline survey
    Murray, KA
    Gilmour, A
    Madden, RH
    JOURNAL OF FOOD PROTECTION, 2001, 64 (04) : 498 - 502
  • [22] Effect of fecal contamination and cross-contamination on numbers of coliform, Escherichia coli, Campylobacter, and Salmonella on immersion-chilled broiler carcasses
    Smith, DP
    Cason, JA
    Berrang, ME
    JOURNAL OF FOOD PROTECTION, 2005, 68 (07) : 1340 - 1345
  • [23] Breast meat quality and consumer sensory properties of broiler carcasses chilled by water, air, or evaporative air
    Jeong, J. Y.
    Janardhanan, K. K.
    Booren, A. M.
    Harte, J. B.
    Kang, I.
    POULTRY SCIENCE, 2011, 90 (03) : 694 - 700
  • [24] Quality of chilled ready-to-bake pizza stored in air and under modified atmospheres: Microbiological and sensory attributes
    Preeti Singh
    Ali Abas Wani
    G. K. Goyal
    Food Science and Biotechnology, 2011, 20 : 1 - 6
  • [25] Quality of Chilled Ready-to-Bake Pizza Stored in Air and under Modified Atmospheres: Microbiological and Sensory Attributes
    Singh, Preeti
    Wani, Ali Abas
    Goyal, G. K.
    FOOD SCIENCE AND BIOTECHNOLOGY, 2011, 20 (01) : 1 - 6
  • [26] Air- versus water-cooled chilled water plants
    Stehney, Mark
    Stehney, Mark, 1600, Cahners Business Information (57): : 6 - 12
  • [27] Effect of gamma irradiation on the microbiological and organoleptic quality of ready prepared chilled meals
    Patterson, MF
    Stevenson, MH
    Grant, IR
    McAteer, NJ
    Stewart, EM
    COMBINATION PROCESSES FOR FOOD IRRADIATION, 1998, : 159 - 179
  • [28] Optimization of a liquid desiccant based dedicated outdoor air-chilled ceiling system serving multi-zone spaces
    Gaoming Ge
    Fu Xiao
    Shengwei Wang
    Building Simulation, 2012, 5 : 257 - 266
  • [29] Modeling and Simulation of Chilled Water System for Central Air Conditioning
    Sun, Jianmin
    Zhang, Chundong
    Zhou, Zeyang
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4280 - 4285
  • [30] A New Air-conditioning System with Chilled Water Storage
    Lin, Hu
    Li, Xinhong
    Cheng, Pengsheng
    Xu, Bugong
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2964 - +