Optimization of a liquid desiccant based dedicated outdoor air-chilled ceiling system serving multi-zone spaces

被引:0
|
作者
Gaoming Ge
Fu Xiao
Shengwei Wang
机构
[1] The Hong Kong Polytechnic University,Department of Building Services Engineering
来源
Building Simulation | 2012年 / 5卷
关键词
dedicated outdoor air system; chilled ceiling; liquid desiccant; building energy efficiency; multi-zone space;
D O I
暂无
中图分类号
学科分类号
摘要
A liquid desiccant based dedicated outdoor air-chilled ceiling (DOAS-CC) system is proposed to serve a multi-zone space. The outdoor airflow rate and the supply air humidity ratio are two crucial variables in such a system, which significantly influence indoor thermal comfort, indoor air quality and energy consumption. Two strategies are presented to optimize these two variables in the study. They are the demand-controlled ventilation (DCV) strategy and the supply air humidity ratio set-point reset strategy. To evaluate the performances of these two strategies, a basic control strategy, i.e., the strategy adopting constant ventilation flow rate and constant supply air humidity ratio, is selected as the benchmark. Performances of the two strategies in terms of indoor air temperature, relative humidity and CO2 concentration as well as energy consumption are analyzed using simulation tests. The results show that the supply air humidity ratio set-point reset strategy is effective for the indoor air humidity control. It can save about 19.4% of total energy consumption during the whole year. The DCV-based ventilation strategy can further reduce about 10.0% of energy consumption.
引用
收藏
页码:257 / 266
页数:9
相关论文
共 31 条
  • [1] Optimization of a liquid desiccant based dedicated outdoor air-chilled ceiling system serving multi-zone spaces
    Ge, Gaoming
    Xiao, Fu
    Wang, Shengwei
    BUILDING SIMULATION, 2012, 5 (03) : 257 - 266
  • [2] Model-based optimal control of a dedicated outdoor air-chilled ceiling system using liquid desiccant and membrane-based total heat recovery
    Ge, Gaoming
    Xiao, Fu
    Xu, Xinhua
    APPLIED ENERGY, 2011, 88 (11) : 4180 - 4190
  • [3] Optimization control method for dedicated outdoor air system in multi-zone office buildings based on deep reinforcement learning
    Tang, Xudong
    Zhang, Ling
    Luo, Yongqiang
    BUILDING SIMULATION, 2025,
  • [4] Control performance of a dedicated outdoor air system adopting liquid desiccant dehumidification
    Xiao, Fu
    Ge, Gaoming
    Niu, Xiaofeng
    APPLIED ENERGY, 2011, 88 (01) : 143 - 149
  • [5] A NOVEL INTEGRATED ENERGY-EFFICIENT DEDICATED OUTDOOR AIR SYSTEM (DOAS) WITH LIQUID DESICCANT
    Chen, Tingyao
    Cui, Mingxian
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON SUSTAINABLE URBANIZATION (ICSU 2010), 2010, : 1875 - 1884
  • [6] Condensation Risk in a Room with a High Latent Load and Chilled Ceiling Panels and with Air Supplied from a Liquid Desiccant System
    Yin, Yonggao
    Zhang, Xiaosong
    Chen, Qingyan
    HVAC&R RESEARCH, 2009, 15 (02): : 315 - 327
  • [7] Applicability of an organic Rankine cycle for a liquid desiccant-assisted dedicated outdoor air system in apartments
    Kim, Beom-Jun
    Dong, Hye-Won
    Jeong, Jae-Weon
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [8] Energy Saving Potential of a Thermoelectric Heat Pump-Assisted Liquid Desiccant System in a Dedicated Outdoor Air System
    Kim, Min-Hwi
    Park, Joon-Young
    Jeong, Jae-Weon
    ENERGIES, 2017, 10 (09):
  • [9] Prediction-based online optimal control of outdoor air of multi-zone VAV air conditioning systems
    Jin, XQ
    Ren, HG
    Xiao, XK
    ENERGY AND BUILDINGS, 2005, 37 (09) : 939 - 944
  • [10] Energy Performance Comparison between Liquid-Desiccant-Assisted Air Conditioning System and Dedicated Outdoor Air System in Different Climatic Regions
    Liu, Su
    No, Sang-Tae
    Jeong, Jae-Weon
    ENERGIES, 2019, 12 (09)