Precise beam delivery for proton therapy with dynamic energy modulation

被引:5
|
作者
Actis, O. [1 ]
Mayor, A. [1 ]
Meer, D. [1 ]
Weber, D. C. [2 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] Univ Hosp Zurich, CH-8091 Zurich, Switzerland
关键词
D O I
10.1088/1742-6596/1067/9/092002
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Gantry 2 at PSI is a Pencil Beam Scanning (PBS) cyclotron-based proton therapy system. The main principle of PBS is a sequential dose-spot delivery to all positions (spots) within the tumour. This technique proved to be an effective treatment method for static tumours, however for mobile targets (e.g. lung or liver) organ motion interferes with beam delivery lowering the treatment quality. A common method to mitigate motion effects is to re-scan the treatment volume multiple times. One distinguishes between iso-layered re-scanning (LR) where all re-scans are performed in a single energy layer before moving to the next energy, and volumetric re-scanning (VR) where the whole tumour volume is re-scanned multiple times. Several studies demonstrate the higher effectiveness of VR [1,2,3]. The downside of this re-scanning type is the increase of treatment time due to high number of energy switches and magnet initializations (ramping) between scans. We developed a novel rescanning concept which increases the dynamics of energy modulation and cuts treatment delivery times in half. Re-evaluating an existing patient treatment plan with this new VR method we demonstrated that our approach with highly dynamic energy modulation allows for a beam delivery precision similar to the standard PBS irradiation.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Proton beam therapy
    Popovic-Vukovic, Marija
    Bokun, Jelena
    Stanic, Dragana
    Nidzovic, Borko
    Nikitovic, Marina
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2021, 149 (11-12) : 741 - 744
  • [32] Proton beam therapy
    Casar, Bozidar
    Strojan, Primoz
    ONKOLOGIJA, 2018, 22 (01) : 12 - 16
  • [33] Proton beam therapy
    Cox, James D.
    JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S274 - S275
  • [34] Proton beam therapy
    W P Levin
    H Kooy
    J S Loeffler
    T F DeLaney
    British Journal of Cancer, 2005, 93 : 849 - 854
  • [35] Proton beam therapy
    Levin, WP
    Kooy, H
    Loeffler, JS
    DeLaney, TF
    BRITISH JOURNAL OF CANCER, 2005, 93 (08) : 849 - 854
  • [36] Proton beam therapy
    不详
    ARCHIVES OF DISEASE IN CHILDHOOD, 2016, 101 (04) : 355
  • [37] Building a precise machine-specific time structure of the spot and energy delivery model for a cyclotron-based proton therapy system
    Zhao, Lewei
    Liu, Gang
    Zheng, Weili
    Shen, Jiajian
    Lee, Andrew
    Yan, Di
    Deraniyagala, Rohan
    Stevens, Craig
    Li, Xiaoqiang
    Tang, Shikui
    Ding, Xuanfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (01):
  • [38] Dynamic Collimation System Controller for Pencil Beam Scanning Proton Therapy
    Patwardhan, K.
    Geoghegan, T.
    Flynn, R.
    Wang, D.
    Hyer, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E97 - E97
  • [39] Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Gutierrez, Alonso N.
    Hill, Patrick M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05):
  • [40] A static beam delivery device for fast scanning proton arc-therapy
    Nesteruk, K. P.
    Bolsi, A.
    Lomax, A. J.
    Meer, D.
    van de Water, S.
    Schippers, J. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):