Precise beam delivery for proton therapy with dynamic energy modulation

被引:5
|
作者
Actis, O. [1 ]
Mayor, A. [1 ]
Meer, D. [1 ]
Weber, D. C. [2 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] Univ Hosp Zurich, CH-8091 Zurich, Switzerland
关键词
D O I
10.1088/1742-6596/1067/9/092002
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Gantry 2 at PSI is a Pencil Beam Scanning (PBS) cyclotron-based proton therapy system. The main principle of PBS is a sequential dose-spot delivery to all positions (spots) within the tumour. This technique proved to be an effective treatment method for static tumours, however for mobile targets (e.g. lung or liver) organ motion interferes with beam delivery lowering the treatment quality. A common method to mitigate motion effects is to re-scan the treatment volume multiple times. One distinguishes between iso-layered re-scanning (LR) where all re-scans are performed in a single energy layer before moving to the next energy, and volumetric re-scanning (VR) where the whole tumour volume is re-scanned multiple times. Several studies demonstrate the higher effectiveness of VR [1,2,3]. The downside of this re-scanning type is the increase of treatment time due to high number of energy switches and magnet initializations (ramping) between scans. We developed a novel rescanning concept which increases the dynamics of energy modulation and cuts treatment delivery times in half. Re-evaluating an existing patient treatment plan with this new VR method we demonstrated that our approach with highly dynamic energy modulation allows for a beam delivery precision similar to the standard PBS irradiation.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A static device for novel fast beam delivery techniques in proton therapy
    Nesteruk, K.
    Lomax, A.
    Bolsi, A.
    Meer, D.
    van de Water, S.
    Schippers, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S748 - S749
  • [22] Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy
    Hyer, Daniel E.
    Bennett, Laura C.
    Geoghegan, Theodore J.
    Bues, Martin
    Smith, Blake R.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 8 (01) : 73 - 83
  • [23] Aperture-based beam delivery for intensity modulated proton therapy
    Fan, J.
    Li, J.
    Luo, W.
    Fourkal, E.
    Stathakis, S.
    Lin, T.
    Ma, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2190 - 2190
  • [24] Proton Linear Energy Transfer Differs According to Beam Delivery Method
    Wilson, L.
    Pirlepesov, F.
    Moskvin, V.
    Merchant, T.
    Faught, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E834 - E834
  • [25] DELIVERY OF PROTON BEAM AT PSI
    Lederer, L.
    Lomax, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S55 - S55
  • [26] Energy modulation of laser accelerated proton beams for radiation therapy
    Shahine, B
    Lee, M
    Boyer, A
    Ma, C
    MEDICAL PHYSICS, 2002, 29 (06) : 1326 - 1326
  • [27] Energy Thresholds in 180 Degree Arc Delivery Proton Therapy
    Sengbusch, E.
    Mackie, T.
    Perez-Andujar, A.
    DeLuca, P.
    MEDICAL PHYSICS, 2008, 35 (06) : 2846 - +
  • [28] A novel approach to the optimization of beam current modulation for proton therapy beam using passive scattering
    Lu, H
    Kooy, H
    MEDICAL PHYSICS, 2005, 32 (06) : 2138 - 2138
  • [29] Development of an adjustable beam flattening system for modification of passive beam delivery technique in proton therapy
    Torshabi, A. Esmaili
    Terakawa, A.
    Ishii, K.
    Yamazaki, H.
    Matsuyama, S.
    Kikuchi, Y.
    Akiyama, H.
    Koyata, K.
    Tagawa, A.
    Itoh, Y.
    Yasunaga, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (01): : 138 - 141
  • [30] Proton beam therapy
    Kim, Dae Yong
    Park, Sung Yong
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2008, 51 (07): : 638 - 642