Precise beam delivery for proton therapy with dynamic energy modulation

被引:5
|
作者
Actis, O. [1 ]
Mayor, A. [1 ]
Meer, D. [1 ]
Weber, D. C. [2 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] Univ Hosp Zurich, CH-8091 Zurich, Switzerland
关键词
D O I
10.1088/1742-6596/1067/9/092002
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Gantry 2 at PSI is a Pencil Beam Scanning (PBS) cyclotron-based proton therapy system. The main principle of PBS is a sequential dose-spot delivery to all positions (spots) within the tumour. This technique proved to be an effective treatment method for static tumours, however for mobile targets (e.g. lung or liver) organ motion interferes with beam delivery lowering the treatment quality. A common method to mitigate motion effects is to re-scan the treatment volume multiple times. One distinguishes between iso-layered re-scanning (LR) where all re-scans are performed in a single energy layer before moving to the next energy, and volumetric re-scanning (VR) where the whole tumour volume is re-scanned multiple times. Several studies demonstrate the higher effectiveness of VR [1,2,3]. The downside of this re-scanning type is the increase of treatment time due to high number of energy switches and magnet initializations (ramping) between scans. We developed a novel rescanning concept which increases the dynamics of energy modulation and cuts treatment delivery times in half. Re-evaluating an existing patient treatment plan with this new VR method we demonstrated that our approach with highly dynamic energy modulation allows for a beam delivery precision similar to the standard PBS irradiation.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] PRECISE ENERGY MEASUREMENT OF THE CONTINUOUS PROTON-BEAM
    FESCHENKO, AV
    OSTROUMOV, PN
    PETRONEVICH, SA
    SHARAMENTOV, SI
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 1409 - 1410
  • [2] Improving the Delivery and Safety of Proton Beam Therapy
    Buchsbaum, J.
    Reed, R.
    Conley, T.
    Babita, J.
    Simoneaux, V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S786 - S786
  • [3] IMPROVING THE DELIVERY AND SAFETY OF PROTON BEAM THERAPY
    Buchsbaum, J.
    Jyoti, B.
    Simoneaux, V.
    Reed, R.
    Conley, T.
    PEDIATRIC BLOOD & CANCER, 2014, 61 : S222 - S222
  • [4] A proton beam energy modulator for rapid proton therapy
    Lu, Xueying
    Li, Zenghai
    Dolgashev, Valery
    Bowden, Gordon
    Sy, Ann
    Tantawi, Sami
    Nanni, Emilio A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (02):
  • [5] Beam delivery sequencing for intensity modulated proton therapy
    Trofimov, A
    Bortfeld, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (10): : 1321 - 1331
  • [6] Energy spectra in the NAC proton therapy beam
    Brooks, FD
    Jones, DTL
    Bowley, CC
    Symons, JE
    Buffler, A
    Allie, MS
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 477 - 480
  • [7] A Novel Approach to Verify the Layer-By-Layer Energy of Scanning Beam Delivery for Proton Therapy
    Lah, J.
    Son, J.
    Moon, S.
    Shin, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E595 - E595
  • [8] A proton beam delivery system for conformal therapy and intensity modulated therapy
    Yu, QC
    Ke, XY
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2001, 25 (08): : 793 - 798
  • [10] The Beam Commissioning of SC Cyclotron-Based Proton Therapy System With Fast Energy Selection and Precise Gantry
    Zhang, Tianjue
    Wang, Chuan
    Yin, Zhiguo
    Jia, Xianlu
    Wang, Yang
    Fu, Wei
    Liu, Jingyuan
    Jin, Zhaojun
    Zhou, Hongji
    Zhang, Suping
    Cai, Hongru
    Pan, Gaofeng
    Zhu, Xiaofeng
    Lin, Jun
    Zhao, Bohan
    Guo, Qiankun
    Liu, Chuanye
    Xiong, Rui
    He, Aolai
    Jiang, Tianyi
    Hu, Mingzhi
    Song, Qiqi
    Ding, Aoxuan
    Jiang, Shangmeng
    Liu, Ping
    Yang, Fangdi
    Huang, Xiesi
    Chu, Zhichao
    Xia, Xiaoxue
    Zhang, Zheyuan
    Qin, Ling
    Ma, Yongjun
    Cheng, Ziyi
    Xu, Zheng
    Le, Hao
    Zhang, Youwen
    Wang, Xi
    Liu, Zhan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2025, 72 (03) : 438 - 445