New laser technologies in ophthalmology for normalisation of intraocular pressure and correction of refraction

被引:9
|
作者
Baum, O. I. [1 ]
Yuzhakov, A. V. [1 ]
Bolshunov, A. V. [2 ]
Siplivyi, V. I. [2 ]
Khomchik, O. V. [2 ]
Zheltov, G. I. [3 ]
Sobol, E. N. [1 ]
机构
[1] Russian Acad Sci, Inst Photon Technol, Fed Sci Res Ctr Crystallog & Photon, Leninsky Prosp 59, Moscow 119333, Russia
[2] Fed State Budgetary Sci Inst, Sci Res Inst Eye Dis, Ul Rossolimo 11A, Moscow 119021, Russia
[3] Natl Acad Sci Belarus, BI Stepanov Inst Phys, Prosp Nezavisimosti 68, Minsk 220072, BELARUS
基金
俄罗斯基础研究基金会;
关键词
laser; glaucoma; refraction; thermotensions; optical methods; structural changes; CORNEA; SCLERA; TISSUE;
D O I
10.1070/QEL16368
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the results of recent studies that develop principally new approaches to solving the problem of visual impairment and provide the basis for new laser technologies in ophthalmology for the treatment of glaucoma, myopia and hypermetropia. The considered theoretical models and optical methods for detecting laser-induced structural changes in eye tissues pave the way to the invention of control systems with feedback, providing efficient and safe laser treatment.
引用
收藏
页码:860 / 866
页数:7
相关论文
共 50 条
  • [1] New technologies for measuring intraocular pressure
    Garcia-Feijoo, Julian
    Martinez-de-la-Casa, Jose Maria
    Morales-Fernandez, Laura
    Frances, Federico Saenz
    Santos-Bueso, Enrique
    Garcia-Saenz, Sofia
    Mendez-Hernandez, Carmen
    NEW TRENDS IN BASIC AND CLINICAL RESEARCH OF GLAUCOMA: A NEURODEGENERATIVE DISEASE OF THE VISUAL SYSTEM, PT B, 2015, 221 : 67 - 79
  • [2] Assessment of new technologies:: the excimer laser in ophthalmology
    Lance, JMR
    Régnier, G
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2001, 36 (03): : 123 - 124
  • [3] New Laser-Based Technologies in Ophthalmology
    Guthoff, Rudolf F.
    Stachs, Oliver
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2009, 226 (12) : 957 - 957
  • [4] INTRAOCULAR-PRESSURE AND REFRACTION
    SHUM, PJT
    VISION RESEARCH, 1995, 35 : 3131 - 3131
  • [5] Assessment of new technologies: the excimer laser in ophthalmology - Discussion
    Brunette, I
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2001, 36 (03): : 124 - 124
  • [6] Influence of laser posterior capsulotomy on anterior chamber depth, refraction, and intraocular pressure
    Hu, CY
    Woung, LC
    Wang, MC
    Jian, JH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08): : 1183 - 1189
  • [7] ORAL GLYCEROL IN OPHTHALMOLOGY - A VALUABLE NEW METHOD FOR REDUCTION OF INTRAOCULAR PRESSURE
    VIRNO, M
    BUCCI, MG
    CANTORE, P
    BIETTI, C
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1963, 55 (06) : 1133 - &
  • [8] Impact of new technologies in ophthalmology
    Forrester, JV
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (11) : 1211 - 1211
  • [9] The Effect of ND:YAG Laser Posterior Capsulotomy Size on Refraction, Intraocular Pressure, and Macular Thickness
    Karahan, Eyyup
    Tuncer, Ibrahim
    Zengin, Mehmet Ozgur
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [10] Accurate intraocular pressure measurement - The myth of modem ophthalmology?
    Shah, S
    OPHTHALMOLOGY, 2000, 107 (10) : 1805 - 1807