Design, fabrication, investigation and analysis of a novel flat evaporator loop heat pipe for cooling high heat flux server chips

被引:36
|
作者
Xiong, Kangning [1 ]
Meng, Like [1 ]
Wang, Shuangfeng [1 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Key Lab Heat Transfer Enhancement & Energy Conser, Minist Educ, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
Loop heat pipe; Flat evaporator; Filling ratios; Capillary performance; Thermal characteristics; Water block; FIBER SINTERED SHEET; THERMAL PERFORMANCE; DATA CENTERS; MANAGEMENT; SYSTEMS; WICK; FLOW;
D O I
10.1016/j.applthermaleng.2021.117775
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel loop heat pipe (LHP) with a flat evaporator has been proposed to meet the heat dissipation requirement of high heat flux server CPU. The sintered porous copper wick was provided with a double arrayed vapor channels to increase the evaporation area. And a 1 mm thick smaller particle size copper powder embedded with two 0.5 mm thick stainless steel rings was sintered on the inner surface of the compensation chamber to enhance the strength, and increase the working fluid into the porous wick such that the liquid saturation was enhanced and the dry zone was reduced at high heat flux. Additionally, a dual layer structure condenser was presented to increase the cooling area of the condenser. In this study, the systematic experimental studies were carried out mainly focusing on the optimization of powder size, heat transfer performance of the novel LHP and performance comparison of the novel LHP. The results demonstrated that the sintered copper powder of the 106-150 mu m particle size shown the best capillary performance in comparison with other powder sizes. More importantly, in the heat load range of 500-750 W, the novel LHP of filling ratio of 46.1% exhibited better operating thermal characteristics. The minimum values of the LHP thermal resistance and the total system thermal resistance at the heat load of 750 W were 0.040 degrees C/W and 0.090 degrees C/W, respectively. Compared with the conventional LHP and the simple water block, the novel flat evaporator LHP was a more promising option when the heat load was higher than 250 W.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Operational characteristics of a miniature loop heat pipe with flat evaporator
    Singh, Randeep
    Akbarzadeh, Aliakbar
    Mochizuki, Masataka
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2008, 47 (11) : 1504 - 1515
  • [32] Complete analytical model of a loop heat pipe with a flat evaporator
    Siedel, Benjamin
    Sartre, Valerie
    Lefevre, Frederic
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 89 : 372 - 386
  • [33] Heat Transfer Investigation in Evaporator of Loop Heat Pipe During Startup
    Chernysheva, M. A.
    Maydanik, Y. F.
    Ochterbeck, J. M.
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2008, 22 (04) : 617 - 622
  • [34] Advanced thermal management system based on a novel flat evaporator loop heat pipe with high-efficiency condenser for electronic cooling
    Xiong, Kangning
    Luo, Yuhao
    Hu, Yixian
    Wang, Shuangfeng
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 196
  • [35] A novel flat rectangular evaporator with the optimized heat leakage paths to improve the heat transfer capability of the loop heat pipe
    Ma, Zhengyuan
    Zhang, Zikang
    Tan, Yubo
    Liu, Wei
    Liu, Zhichun
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [36] Investigation of the Effect of Heat Leak in Loop Heat Pipes with Flat Evaporator
    Wu, Shen-Chun
    Peng, Jen-Chieh
    Lai, Shih-Ru
    Yeh, Chien-Chih
    Chen, Yau-Ming
    IMPACT: 2009 4TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE, 2009, : 313 - +
  • [37] Operating characteristics of a dual flat-evaporator loop heat pipe for single heat source cooling in any orientation
    Nguyen Phan
    Saito, Yuki
    Katayama, Naoki
    Nagano, Hosei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 172
  • [38] Experimental study on a novel loop heat pipe with both flat evaporator and boiling pool
    Lu, Xiao
    Wei, Jin-Jia
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 79 : 54 - 63
  • [39] Experimental investigation of flat porous heat pipe for cooling TV box electronic chips
    Zeghari, K.
    Louahlia, H.
    Le Masson, S.
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [40] Effect of groove size on heat transfer performance of loop heat pipe with flat evaporator
    Lü, Xiao
    Wei, Jin-Jia
    Long, Yan
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2015, 36 (03): : 611 - 614