Local minima in anatomic aperture-based IMRT optimization

被引:0
|
作者
Aubry, J
Beaulieu, F
Beaulieu, L
Tremblay, D
机构
[1] Ctr Hosp Univ Quebec, Quebec City, PQ, Canada
[2] Univ Laval, Quebec City, PQ, Canada
关键词
D O I
10.1118/1.1997785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An anatomic aperture‐based IMRT optimization program, named Ballista, was recently developed at our institution. Even though studies previously published concluded local minima in full‐IMRT optimization were not problematic, early observations with Ballista revealed their nuisance in the case of simplified IMRT. The purpose of this study was to evaluate the extent of local minima and their impact on the optimization process.Method and Materials: In Ballista beam weights are optimized by a bound‐constrained quasi‐Newton algorithm, which cannot escape local minima, even with a quadratic dose‐based objective function. Therefore, a high number (20 000) of descents were launched with random initial weights to explore the solution space for a varying number of beams. Actual treatment plan DVHs corresponding to different local minima were analyzed, yielding information on the nature of those minima. Results: When only four beam weights were optimized, only a few but very distinctive local minima were found. For a more realistic case of 20 beam weights, the optimization revealed an astonishing number of local minima, almost forming a continuum in the objective function value space. DVH analysis showed local minima generally favor one or more organs‐at‐risk (OARs) while the other objectives, especially those concerning the target volume, are less than optimal compared with the global minimum. Also, all minima lie on the boundary of the solution space. It was found that limiting the initial beam weights to small values eliminates the vast majority of the solution space containing local minima. Conclusion: With Ballista local minima proved to be a major problem. Plans corresponding to different minima differed drastically. In order to give the optimization a “clear shot” at the global minimum, initial beam weights must be limited to small values. This focuses the optimization on improving the target volume objectives since all OARs objectives are initially met. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1976 / 1976
页数:1
相关论文
共 50 条
  • [41] Towards functional image-guided inverse planning for lung cancer using spect perfusion imaging and aperture-based IMRT
    St-Hilaire, J.
    Lavoie, C.
    Beaulieu, F.
    Dagnault, A.
    Tremblay, D.
    Beaulieu, L.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S198 - S199
  • [42] Graphene aperture-based metalens for dynamic focusing of terahertz waves
    Ding, Pei
    Li, Yan
    Shao, Li
    Tian, Ximin
    Wang, Junqiao
    Fan, Chunzhen
    OPTICS EXPRESS, 2018, 26 (21): : 28038 - 28050
  • [43] A Novel Aperture-Based Algorithm for Fast Treatment Plan Optimization of Volumetric Modulated Arc Therapy (VMAT)
    Men, C.
    Romeijn, E.
    Jia, X.
    Gu, X.
    Liang, Y.
    Jiang, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [44] Aperture-based antihydrogen gravity experiment: Parallel plate geometry
    Rocha, J. R.
    Hedlof, R. M.
    Ordonez, C. A.
    AIP ADVANCES, 2013, 3 (10):
  • [45] ADIABATIC OPTIMIZATION WITHOUT LOCAL MINIMA
    Jarret, Michael
    Jordan, Stephen P.
    QUANTUM INFORMATION & COMPUTATION, 2015, 15 (3-4) : 181 - 199
  • [46] Adiabatic optimization without local minima
    Jarret, Michael
    Jordan, Stephen P.
    Quantum Information and Computation, 2015, 15 (3-4): : 181 - 199
  • [47] Synthetic aperture-based beam compression for intravascular ultrasound imaging
    Vray, D
    Haas, C
    Rastello, T
    Krueger, M
    Brusseau, E
    Schroeder, K
    Gimenez, G
    Ermert, H
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) : 189 - 201
  • [48] Coarse Estimation of the Incident Angle for VLP with an Aperture-Based Receiver
    Bastiaens, Sander
    Steendam, Heidi
    2017 14TH WORKSHOP ON POSITIONING, NAVIGATION AND COMMUNICATIONS (WPNC), 2017,
  • [49] Direct aperture optimization based step-and-shoot IMRT with respiratory gating
    Ahunbay, E.
    Jursinic, P.
    Li, X. A.
    MEDICAL PHYSICS, 2006, 33 (06) : 2217 - 2217
  • [50] An aperture-based inverse planning algorithm for modulated electron radiation therapy
    Jiang, SB
    Pawlicki, T
    Ma, CM
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 116 - 118