Local minima in anatomic aperture-based IMRT optimization

被引:0
|
作者
Aubry, J
Beaulieu, F
Beaulieu, L
Tremblay, D
机构
[1] Ctr Hosp Univ Quebec, Quebec City, PQ, Canada
[2] Univ Laval, Quebec City, PQ, Canada
关键词
D O I
10.1118/1.1997785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An anatomic aperture‐based IMRT optimization program, named Ballista, was recently developed at our institution. Even though studies previously published concluded local minima in full‐IMRT optimization were not problematic, early observations with Ballista revealed their nuisance in the case of simplified IMRT. The purpose of this study was to evaluate the extent of local minima and their impact on the optimization process.Method and Materials: In Ballista beam weights are optimized by a bound‐constrained quasi‐Newton algorithm, which cannot escape local minima, even with a quadratic dose‐based objective function. Therefore, a high number (20 000) of descents were launched with random initial weights to explore the solution space for a varying number of beams. Actual treatment plan DVHs corresponding to different local minima were analyzed, yielding information on the nature of those minima. Results: When only four beam weights were optimized, only a few but very distinctive local minima were found. For a more realistic case of 20 beam weights, the optimization revealed an astonishing number of local minima, almost forming a continuum in the objective function value space. DVH analysis showed local minima generally favor one or more organs‐at‐risk (OARs) while the other objectives, especially those concerning the target volume, are less than optimal compared with the global minimum. Also, all minima lie on the boundary of the solution space. It was found that limiting the initial beam weights to small values eliminates the vast majority of the solution space containing local minima. Conclusion: With Ballista local minima proved to be a major problem. Plans corresponding to different minima differed drastically. In order to give the optimization a “clear shot” at the global minimum, initial beam weights must be limited to small values. This focuses the optimization on improving the target volume objectives since all OARs objectives are initially met. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1976 / 1976
页数:1
相关论文
共 50 条
  • [21] Couch and aperture-based correction in IGRT
    Scherer, P.
    Deutschmann, H.
    Steininger, P.
    Keuschnigg, P.
    Zechner, A.
    Koch, A. K.
    Sedlmayer, F.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S88 - S88
  • [22] Synthetic aperture-based on-chip microscopy
    Wei Luo
    Alon Greenbaum
    Yibo Zhang
    Aydogan Ozcan
    Light: Science & Applications, 2015, 4 : e261 - e261
  • [23] Dynamic aperture-based solar loop segmentation
    Lee, Jong Kwan
    Newman, Timothy S.
    Gary, G. Allen
    7TH IEEE SOUTHWEST SYMPOSIUM ON IMAGE ANALYSIS AND INTERPRETATION, 2006, : 91 - +
  • [24] Super Unit Cells in Aperture-Based Metamaterials
    Tanaskovic, Dragan
    Jaksic, Zoran
    Obradov, Marko
    Jaksic, Olga
    JOURNAL OF NANOMATERIALS, 2015, 2015
  • [25] Simulation of an aperture-based antihydrogen gravity experiment
    Ordonez, C. A.
    Hedlof, R. M.
    AIP ADVANCES, 2012, 2 (01):
  • [26] Synthetic aperture-based on-chip microscopy
    Luo, Wei
    Greenbaum, Alon
    Zhang, Yibo
    Ozcan, Aydogan
    LIGHT-SCIENCE & APPLICATIONS, 2015, 4 : e261 - e261
  • [27] Aperture based optimization for static IMRT using genetic algorithm
    Li, YJ
    Yao, J
    Yao, DZ
    MEDICAL PHYSICS, 2003, 30 (06) : 1372 - 1372
  • [28] Implementation of Aperture-Based Complexity Metrics of MLC Opening based on the IMRT Technique for Central Nervous System (CNS) and Breast Cases
    Ambalinggi, Meirisa
    Putranto, Aloysius Mario Yudi
    Prasada, Dewa Ngurah Yudhi
    Gayatri, Ida Ayu Putu Inten
    Pawiro, Supriyanto Ardjo
    Sihono, Dwi Seno Kuncoro
    Iranian Journal of Medical Physics, 2024, 21 (02) : 71 - 77
  • [29] Simplifying IMRT with direct aperture optimization
    Earl, M
    Shepard, D
    Li, XA
    Naqvi, S
    Yu, CX
    MEDICAL PHYSICS, 2002, 29 (06) : 1305 - 1305
  • [30] Simplifying IMRT with direct aperture optimization
    Yu, C
    Shepard, D
    Earl, M
    Yi, B
    MEDICAL PHYSICS, 2005, 32 (06) : 2084 - 2085