Local minima in anatomic aperture-based IMRT optimization

被引:0
|
作者
Aubry, J
Beaulieu, F
Beaulieu, L
Tremblay, D
机构
[1] Ctr Hosp Univ Quebec, Quebec City, PQ, Canada
[2] Univ Laval, Quebec City, PQ, Canada
关键词
D O I
10.1118/1.1997785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An anatomic aperture‐based IMRT optimization program, named Ballista, was recently developed at our institution. Even though studies previously published concluded local minima in full‐IMRT optimization were not problematic, early observations with Ballista revealed their nuisance in the case of simplified IMRT. The purpose of this study was to evaluate the extent of local minima and their impact on the optimization process.Method and Materials: In Ballista beam weights are optimized by a bound‐constrained quasi‐Newton algorithm, which cannot escape local minima, even with a quadratic dose‐based objective function. Therefore, a high number (20 000) of descents were launched with random initial weights to explore the solution space for a varying number of beams. Actual treatment plan DVHs corresponding to different local minima were analyzed, yielding information on the nature of those minima. Results: When only four beam weights were optimized, only a few but very distinctive local minima were found. For a more realistic case of 20 beam weights, the optimization revealed an astonishing number of local minima, almost forming a continuum in the objective function value space. DVH analysis showed local minima generally favor one or more organs‐at‐risk (OARs) while the other objectives, especially those concerning the target volume, are less than optimal compared with the global minimum. Also, all minima lie on the boundary of the solution space. It was found that limiting the initial beam weights to small values eliminates the vast majority of the solution space containing local minima. Conclusion: With Ballista local minima proved to be a major problem. Plans corresponding to different minima differed drastically. In order to give the optimization a “clear shot” at the global minimum, initial beam weights must be limited to small values. This focuses the optimization on improving the target volume objectives since all OARs objectives are initially met. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1976 / 1976
页数:1
相关论文
共 50 条
  • [1] Local minima in anatomic aperture-based IMRT optimization
    Aubry, J
    Beaulieu, F
    Beaulieu, L
    Tremblay, D
    MEDICAL PHYSICS, 2005, 32 (07) : 2413 - 2413
  • [2] An optimization algorithm for aperture-based IMRT treatment planning
    Hou, Q
    Galvin, J
    Chen, Y
    MEDICAL PHYSICS, 2003, 30 (06) : 1373 - 1373
  • [3] Relationship of segment area and monitor unit efficiency in aperture-based IMRT optimization
    Qi, Peng
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 232 - 243
  • [4] Dosimetric Evaluation of Aperture-Based and Beamlet-Based Optimization for Conventional IMRT/VMAT and SBRT
    Wu, D.
    Eldib, A.
    Jiang, Q.
    Chen, L.
    Ma, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [5] Aperture-based IMRT inverse planning with incorporation of organ motion
    Shou, Z
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S631 - S632
  • [6] Automatic generation of anatomy-based MLC fields in aperture-based IMRT
    Beaulieu, F
    Beaulieu, L
    Tremblay, D
    Lachance, B
    Roy, R
    MEDICAL PHYSICS, 2004, 31 (06) : 1539 - 1545
  • [7] Multiple local minima in IMRT optimization based on dose-volume criteria
    Wu, QW
    Mohan, R
    MEDICAL PHYSICS, 2002, 29 (07) : 1514 - 1527
  • [8] Aperture-based IMRT for resected endometrial cancer: Clinical results with treatment delivery improvement
    Bouchard, M.
    Nadeau, S.
    Germain, I.
    Raymond, P-E.
    Beaulieu, F.
    Beaulieu, L.
    Roy, R.
    Harel, F.
    Gingras, L.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S366 - S366
  • [9] A 3-Step Methodology-Cum-Algorithm for Fast Optimization of Beam Weights and Shapes in Aperture-Based IMRT
    Ranganathan, Vaitheeswaran
    Vatyam, V. K. Sathiya Narayanan
    Bhangle, Janhavi
    Gupta, Kamlesh
    Basu, Sumit
    Maiya, Vikram
    Achari, Rimpa
    MEDICAL PHYSICS, 2009, 36 (06) : 2558 - 2559
  • [10] Aperture-based IMRT for resected endometrial cancer : Clinical results with treatment delivery improvement
    Bouchard, M.
    Nadeau, S.
    Germain, I.
    Raymond, P.
    Beaulieu, F.
    Beaulieu, L.
    Roy, R.
    Harel, F.
    Gingras, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S403 - S403