Validation of radiological reduction criteria with intraoperative cone beam CT in unstable syndesmotic injuries

被引:16
|
作者
Vetter, Sven Yves [1 ]
Euler, Jeannie [1 ]
Beisemann, Nils [1 ]
Swartman, Benedict [1 ]
Keil, Holger [1 ]
Gruetzner, Paul Alfred [1 ]
Franke, Jochen [1 ]
机构
[1] Heidelberg Univ Hosp, MINTOS Med Imaging & Nav Trauma & Orthopaed Surg, BG Trauma Ctr Ludwigshafen, Ludwig Guttmannstr 13, D-67071 Ludwigshafen, Germany
关键词
Cone beam CT; Ankle mortise; Syndesmotic lesion; Syndesmosis; ANKLE SYNDESMOSIS; RADIOGRAPHIC EVALUATION; MALREDUCTION; FRACTURES; DIASTASIS; FIXATION; SCREW;
D O I
10.1007/s00068-020-01299-z
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose Acute unstable syndesmotic lesions are regularly treated with closed or open reduction and fixation with either a positioning screw or tight rope. Conventional fluoroscopy is limited to identify a malreduction of the ankle mortise. The aim of the study was to validate the reduction criteria of intraoperative cone beam CT in unstable syndesmotic injuries by analyzing the clinical outcome. Methods Acute unstable syndesmotic injuries were treated with a positioning screw fixation, and the reduction in the ankle mortise was evaluated with intraoperative cone beam CT. The patients were grouped postoperatively according to the radiological reduction criteria in the intraoperative 3D images. The reduction criteria were unknown to the surgeons. Malreduction was assumed if one or more reduction criteria were not fulfilled. Results Seventy-three of the 127 patients could be included in the study (follow-up rate 57.5%). For 41 patients (56.2%), a radiological optimal reduction was achieved (Group 1), and in 32 patients (43.8%) a radiological adverse reduction was found (Group 2). Group 1 scored significantly higher in the Olerud/Molander score (92.44 +/- 10.73 vs. 65.47 +/- 28.77) (p = 0.003), revealed a significantly higher range of motion (ROM) (53.44 vs. 24.17 degrees) (p = 0.001) and a significantly reduced Kellgren/Lawrence osteoarthritis score (1.24 vs. 1.79) (p = 0.029). The linear regression analysis revealed a correlation for the two groups with the values scored in the Olerud/Molander score (p < 0.01). Conclusion The reduction criteria in intraoperative cone beam CT applied to unstable syndesmotic injuries could be validated. Patients with an anatomic reduced acute unstable syndesmotic injury according to the criteria have a significantly better clinical outcome.
引用
收藏
页码:897 / 903
页数:7
相关论文
共 50 条
  • [41] Portable Cone Beam CT for Intraoperative Marking of Small Pulmonary Nodules; Anywhere, Anytime!
    Mitsuoka, N.
    Yokoyama, S.
    Kashihara, M.
    Terazaki, Y.
    Mitsuoka, M.
    JOURNAL OF THORACIC ONCOLOGY, 2024, 19 (10) : S534 - S535
  • [42] A comparison of dose reduction methods on image quality for cone beam CT
    Webb, R.
    Buckley, L. A.
    MEDICAL PHYSICS, 2014, 41 (08) : 23 - 23
  • [43] Can real-time RGBD enhance intraoperative Cone-Beam CT?
    Fotouhi, Javad
    Fuerst, Bernhard
    Wein, Wolfgang
    Navab, Nassir
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (07) : 1211 - 1219
  • [44] Reduction of artifacts induced by misaligned geometry in cone-beam CT
    Sun, Yi
    Hou, Ying
    Hu, Jiasheng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (08) : 1461 - 1471
  • [45] Intraoperative cone-beam CT spatial priors for diffuse optical fluorescence tomography
    Daly, M. J.
    Chan, H.
    Muhanna, N.
    Akens, M. K.
    Wilson, B. C.
    Irish, J. C.
    Jaffray, D. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [46] Can real-time RGBD enhance intraoperative Cone-Beam CT?
    Javad Fotouhi
    Bernhard Fuerst
    Wolfgang Wein
    Nassir Navab
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 1211 - 1219
  • [47] Evaluation of the dental spectral cone beam CT for metal artefact reduction
    Zhu, Ling
    Chen, Yi
    Yang, Jie
    Tao, Xiaofeng
    Xi, Yan
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (02)
  • [48] Metal Artifact Reduction in Cone-beam CT by Constrained Optimization
    Zhang, X.
    Wang, J.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S652 - S652
  • [49] AN ALGORITHM FOR METAL STREAKING ARTIFACT REDUCTION IN CONE BEAM CT FOR BRACHYTHERAPY
    Bazalova, M.
    Landry, G.
    Beaulieu, L.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S101 - S101
  • [50] Reduction of the streak artifacts in circular cone beam CT using scanograms
    Zou, Yu
    Zamyatin, Alexander A.
    Chiang, Beshan S.
    Silver, Michael D.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3531 - 3536