Can real-time RGBD enhance intraoperative Cone-Beam CT?

被引:13
|
作者
Fotouhi, Javad [1 ]
Fuerst, Bernhard [1 ]
Wein, Wolfgang [2 ]
Navab, Nassir [1 ,3 ]
机构
[1] Johns Hopkins Univ, Comp Aided Med Procedures, Baltimore, MD 21218 USA
[2] ImFusion GmbH, Munich, Germany
[3] Tech Univ Munich, Comp Aided Med Procedures, Munich, Germany
基金
美国国家卫生研究院;
关键词
Cone-Beam CT; RGBD; Intraoperative; Tomographic reconstruction; MLEM; Algebraic reconstruction; ALGEBRAIC RECONSTRUCTION; IMAGE-RECONSTRUCTION; CAMERA; CALIBRATION; MOTION;
D O I
10.1007/s11548-017-1572-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Cone-Beam Computed Tomography (CBCT) is an important 3D imaging technology for orthopedic, trauma, radiotherapy guidance, angiography, and dental applications. The major limitation of CBCT is the poor image quality due to scattered radiation, truncation, and patient movement. In this work, we propose to incorporate information from a co-registered Red-Green-Blue-Depth (RGBD) sensor attached near the detector plane of the C-arm to improve the reconstruction quality, as well as correcting for undesired rigid patient movement. Methods Calibration of the RGBD and C-arm imaging devices is performed in two steps: (i) calibration of the RGBD sensor and the X-ray source using a multimodal checkerboard pattern, and (ii) calibration of the RGBD surface reconstruction to the CBCT volume. The patient surface is acquired during the CBCT scan and then used as prior information for the reconstruction using Maximum-Likelihood Expectation-Maximization. An RGBD-based simultaneous localization and mapping method is utilized to estimate the rigid patient movement during scanning. Results Performance is quantified and demonstrated using artificial data and bone phantoms with and without metal implants. Finally, we present movement-corrected CBCT reconstructions based on RGBD data on an animal specimen, where the average voxel intensity difference reduces from 0.157 without correction to 0.022 with correction. Conclusion This work investigated the advantages of a C-arm X-ray imaging system used with an attached RGBD sensor. The experiments show the benefits of the opto/X-ray imaging system in: (i) improving the quality of reconstruction by incorporating the surface information of the patient, reducing the streak artifacts as well as the number of required projections, and (ii) recovering the scanning trajectory for the reconstruction in the presence of undesired patient rigid movement.
引用
收藏
页码:1211 / 1219
页数:9
相关论文
共 50 条
  • [1] Can real-time RGBD enhance intraoperative Cone-Beam CT?
    Javad Fotouhi
    Bernhard Fuerst
    Wolfgang Wein
    Nassir Navab
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 1211 - 1219
  • [2] Assessment and validation of glottic motion using cone-beam CT and real-time cine MRI
    Seok-Joo Chun
    Jaeman Son
    Seonghee Kang
    Chang Heon Choi
    Jung-in Kim
    Young-Il Kim
    Joo Ho Lee
    Jin Ho Kim
    Hong-Gyun Wu
    Strahlentherapie und Onkologie, 2024, 200 : 418 - 424
  • [3] Assessment and validation of glottic motion using cone-beam CT and real-time cine MRI
    Chun, Seok-Joo
    Son, Jaeman
    Kang, Seonghee
    Choi, Chang Heon
    Kim, Jung-in
    Kim, Young-Il
    Lee, Joo Ho
    Kim, Jin Ho
    Wu, Hong-Gyun
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (05) : 418 - 424
  • [4] Workflow and performance of intraoperative CT, cone-beam CT, and robotic cone-beam CT for spinal navigation in 503 consecutive patients
    Kendlbacher, Paul
    Tkatschenko, Dimitri
    Czabanka, Marcus
    Bayerl, Simon
    Bohner, Georg
    Woitzik, Johannes
    Vajkoczy, Peter
    Hecht, Nils
    NEUROSURGICAL FOCUS, 2022, 52 (01)
  • [5] Intraoperative cone-beam CT for guidance of temporal bone surgery
    Rafferty, MA
    Siewerdsen, JH
    Chan, Y
    Daly, MJ
    Moseley, DJ
    Jaffray, DA
    Irish, JC
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2006, 134 (05) : 801 - 808
  • [6] Automatic intraoperative stitching of nonoverlapping cone-beam CT acquisitions
    Fotouhi, Javad
    Fuerst, Bernhard
    Unberath, Mathias
    Reichenstein, Stefan
    Lee, Sing Chun
    Johnson, Alex A.
    Osgood, Greg M.
    Armand, Mehran
    Navab, Nassir
    MEDICAL PHYSICS, 2018, 45 (06) : 2463 - 2475
  • [7] Real-Time Delineation of Implanted Cardioverter-Defibrillators and Metal Artifact Reduction in Cardiac Cone-Beam CT
    Park, I.
    Chun, J.
    Olberg, S.
    Cai, B.
    Hugo, G.
    Robinson, C. G.
    Kim, J.
    Mutic, S.
    Park, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E444 - E444
  • [8] Intraoperative imaging and navigation with mobile cone-beam CT in maxillofacial surgery
    Quentin Goguet
    Sang Hwy Lee
    Julie Longis
    Pierre Corre
    Hélios Bertin
    Oral and Maxillofacial Surgery, 2019, 23 : 487 - 491
  • [9] Intraoperative imaging and navigation with mobile cone-beam CT in maxillofacial surgery
    Goguet, Quentin
    Lee, Sang Hwy
    Longis, Julie
    Corre, Pierre
    Bertin, Helios
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2019, 23 (04): : 487 - 491
  • [10] Clinical Implementation of Intraoperative Cone-Beam CT in Head and Neck Surgery
    Daly, M. J.
    Chan, H.
    Nithiananthan, S.
    Qiu, J.
    Barker, E.
    Bachar, G.
    Dixon, B. J.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964