Evaluation and Prediction of Flashover Voltage on Contaminated Composite Insulators

被引:0
|
作者
Kiruthika, M. [1 ]
Sivadasan, J. [1 ]
机构
[1] Natl Engn Coll, Dept EEE, Kovilpatti 628503, India
关键词
Silicon rubber; hydrophobicity; prediction; ESDD; insulator design; ANN; LS-SVM;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Insulators plays a vital role in electrical transmission line. It gives a support and separate electrical conductors and these insulators are most commonly made up of porcelain. These insulators gets polluted when they are placed near different atmospheric conditionlike coastal, desert etc. Now-a-days porcelain insulators are replaced by the silicon rubber insulators due its hydrophobicity property. The design parameters of silicon rubber insulator such as creepage factor, profile factor also contributes the pollution flashover. In order to assess the pollution severity level and to prevent the unpredictable flashover voltage, it is important to predict the flashover before it takes place. In this paper, four different types of 11 kV silicon rubber insulators were taken and solid layer method was used in artificial pollution test, in which sodium chloride and kaolin are used to induce the conductivity. Using even rising method, the flashover voltage has been obtained for different equivalent salt deposit density (ESDD) values. By using artificial neural network(ANN) and least square support vector machine (LS-SVM) flashover voltage has been predicted with the input parameters such as height, creepage length, diameter and ESDD. Finally, it is concluded that the LS-SVM approach has better ability to assist the flashover voltage prediction than ANN.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] MINIMUM FLASHOVER VOLTAGE OF ICED INSULATORS
    PHAN, LC
    MATSUO, H
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1983, 18 (06): : 605 - 618
  • [22] FLASHOVER TESTS ON DUST-CONTAMINATED INSULATORS
    RIZK, FAM
    ASSAAD, AA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (01): : 328 - &
  • [23] SWITCHING SURGE FLASHOVER CHARACTERISTICS OF CONTAMINATED INSULATORS
    KAWAGUCH.Y
    TAKAGI, K
    ELECTRICAL ENGINEERING IN JAPAN, 1972, 91 (03) : 71 - &
  • [24] Evaluation on Flashover Voltage Property of Snow Accreted Insulators for Overhead Transmission Lines, Part II-Flashover Characteristics Under Salt Contaminated Snowstorm
    Yaji, Kohei
    Homma, Hiroya
    Aso, Teruo
    Watanabe, Masato
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2559 - 2567
  • [25] The evaluation of asymmetrically aging effect on silicon rubber insulators flashover voltage
    Seyyedbarzegar, Seyyedmeysam
    WORLD JOURNAL OF ENGINEERING, 2025,
  • [26] Flashover voltage prediction of polluted glass insulators based on the characteristics of leakage current
    Zhao, Shihua
    Jiang, Xingliang
    Zhang, Zhijin
    Hu, Jianlin
    Dianwang Jishu/Power System Technology, 2014, 38 (02): : 440 - 447
  • [27] Flashover Voltage Prediction Models under Agricultural and Biological Contaminant Conditions on Insulators
    Khatoon, Shabana
    Khan, Asfar Ali
    Tariq, Mohd
    Alamri, Basem
    Mihet-Popa, Lucian
    ENERGIES, 2022, 15 (04)
  • [28] Prediction of flashover voltage using electric field measurement on clean and polluted insulators
    Cui, L.
    Ramesh, M.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 116
  • [29] Prediction of flashover voltage of insulators using least squares support vector machines
    Gencoglu, Muhsin Tunay
    Uyar, Murat
    EXPERT SYSTEMS WITH APPLICATIONS, 2009, 36 (07) : 10789 - 10798
  • [30] Prediction of flashover voltage of contaminated insulator using artificial neural networks
    Al Alawi, Saleh
    Salam, M. A.
    Maqrashi, A. A.
    Ahmad, Hussein
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2006, 34 (08) : 831 - 840