Influence of the difference in refractive index on the interface of an object and the surroundings in near-infrared fluorescence tomography

被引:2
|
作者
Takematsu, Maho [1 ]
Umezawa, Masakazu [1 ]
Sera, Toshihiro [2 ]
Kitagawa, Yuichi [1 ]
Kurahashi, Hiroyuki [1 ]
Yamada, Shuta [1 ]
Okubo, Kyohei [1 ]
Kamimura, Masao [1 ]
Yokota, Hideo [3 ]
Soga, Kohei [1 ]
机构
[1] Tokyo Univ Sci, Fac Adv Engn, Dept Mat Sci & Technol, 6-3-1 Niijuku, Tokyo 1258585, Japan
[2] Kyushu Univ, Fac Engn, Dept Mech Engn, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
[3] RIKEN, Image Proc Team, Ctr Adv Photon, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
基金
日本科学技术振兴机构;
关键词
OPTICAL TOMOGRAPHY; EXPRESSION; WINDOW; LIGHT;
D O I
10.1364/AO.445357
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The refraction of fluorescence from the inside of a sample at the surface results in fluctuations in fluorescence computed tomography (CT). We evaluated the influence of the difference in refractive index (RI) between the sample body and the surroundings on fluorescence CT results. The brightest fluorescent point is away from the correct point on the tomograms owing to the refraction. The speculated position is determined as the exact point if the RI ratio ranges between 0.97 and 1.03 by immersing the body in an RI matching liquid. The results can help in experimental settings of fluorescence CT for acquiring three-dimensional positional information. (C) 2022 Optica Publishing Group
引用
收藏
页码:638 / 644
页数:7
相关论文
共 50 条
  • [31] Near-infrared fluorescence in robotic thyroidectomy
    Muraveika, Liudmila
    Kose, Emin
    Berber, Eren
    GLAND SURGERY, 2020, 9 : S147 - S152
  • [32] Near-infrared II fluorescence imaging
    Elizabeth Lea Schmidt
    Zihao Ou
    Erving Ximendes
    Han Cui
    Carl H. C. Keck
    Daniel Jaque
    Guosong Hong
    Nature Reviews Methods Primers, 4
  • [33] Intraoperative Near-Infrared Fluorescence Imaging
    Yazdanfar, Siavash
    Latham, Stephen A.
    Lee, Deborah S.
    Lester, Carl S.
    Filkins, Robert J.
    Lomnes, Stephen J.
    Frangioni, John V.
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 2416 - +
  • [34] Near-infrared fluorescence imaging in immunotherapy
    Ji, Yuanyuan
    Jones, Catherine
    Baek, Yoonji
    Park, G. Kate
    Kashiwagi, Satoshi
    Choi, Hak Soo
    ADVANCED DRUG DELIVERY REVIEWS, 2020, 167 : 121 - 134
  • [35] In vivo near-infrared fluorescence imaging
    Frangioni, JV
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2003, 7 (05) : 626 - 634
  • [36] Near-infrared diffuse optical tomography
    Hielscher, AH
    Bluestone, AY
    Abdoulaev, GS
    Klose, AD
    Lasker, J
    Stewart, M
    Netz, U
    Beuthan, J
    DISEASE MARKERS, 2002, 18 (5-6) : 313 - 337
  • [37] Isotropic negative refractive index at near infrared
    Morits, Dmitry
    Simovski, Constantin
    JOURNAL OF OPTICS, 2012, 14 (12)
  • [38] Interferometric measurements of refractive index dispersion in polymers over the visible and near-infrared spectral range
    Caudill, SE
    Grubbs, WT
    JOURNAL OF APPLIED POLYMER SCIENCE, 2006, 100 (01) : 65 - 72
  • [39] Tailored silver coated polymer pillar metasurfaces for near-infrared refractive index sensing applications
    Nguyen, Xuan Bach
    Nguyen, Huu Tu
    Pham, Thanh Son
    Le, Khai Q.
    Ngo, Quang Minh
    PHYSICA B-CONDENSED MATTER, 2024, 689
  • [40] Highly sensitive refractive index sensing with a perfect MIM absorber in visible to near-infrared range
    Kaium, Sk Md Abdul
    Mollah, Md Aslam
    NANOTECHNOLOGY, 2025, 36 (16)