Influence of the difference in refractive index on the interface of an object and the surroundings in near-infrared fluorescence tomography

被引:2
|
作者
Takematsu, Maho [1 ]
Umezawa, Masakazu [1 ]
Sera, Toshihiro [2 ]
Kitagawa, Yuichi [1 ]
Kurahashi, Hiroyuki [1 ]
Yamada, Shuta [1 ]
Okubo, Kyohei [1 ]
Kamimura, Masao [1 ]
Yokota, Hideo [3 ]
Soga, Kohei [1 ]
机构
[1] Tokyo Univ Sci, Fac Adv Engn, Dept Mat Sci & Technol, 6-3-1 Niijuku, Tokyo 1258585, Japan
[2] Kyushu Univ, Fac Engn, Dept Mech Engn, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
[3] RIKEN, Image Proc Team, Ctr Adv Photon, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
基金
日本科学技术振兴机构;
关键词
OPTICAL TOMOGRAPHY; EXPRESSION; WINDOW; LIGHT;
D O I
10.1364/AO.445357
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The refraction of fluorescence from the inside of a sample at the surface results in fluctuations in fluorescence computed tomography (CT). We evaluated the influence of the difference in refractive index (RI) between the sample body and the surroundings on fluorescence CT results. The brightest fluorescent point is away from the correct point on the tomograms owing to the refraction. The speculated position is determined as the exact point if the RI ratio ranges between 0.97 and 1.03 by immersing the body in an RI matching liquid. The results can help in experimental settings of fluorescence CT for acquiring three-dimensional positional information. (C) 2022 Optica Publishing Group
引用
收藏
页码:638 / 644
页数:7
相关论文
共 50 条
  • [21] REFRACTIVE INDEX MEASUREMENTS IN THE NEAR INFRARED
    CARLAN, AJ
    PAUL, FW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (09): : 772 - 773
  • [22] Near-Infrared Perfect Absorption and Refractive Index Sensing Enabled by Split Ring Nanostructures
    Ali, Wajid
    Liu, Weitao
    Liu, Ye
    Li, Ziwei
    NANOMATERIALS, 2023, 13 (19)
  • [23] A highly Sensitive Refractive Index Sensor Based on Fano Resonance in the Near-Infrared Band
    Liu, Jiatang
    Li, Shilei
    Qi, Yanan
    Chen, Shuai
    PLASMONICS, 2025,
  • [24] Complex refractive index of normal and malignant human colorectal tissue in the visible and near-infrared
    Giannios, Panagiotis
    Koutsoumpos, Spyridon
    Toutouzas, Konstantinos G.
    Matiatou, Maria
    Zografos, George C.
    Moutzouris, Konstantinos
    JOURNAL OF BIOPHOTONICS, 2017, 10 (02) : 303 - 310
  • [25] Near-infrared refractive index of synthetic single crystal and polycrystalline diamonds at high temperatures
    Yurov, V. Yu.
    Bushuev, E. V.
    Popovich, A. F.
    Bolshakov, A. P.
    Ashkinazi, E. E.
    Ralchenko, V. G.
    JOURNAL OF APPLIED PHYSICS, 2017, 122 (24)
  • [26] Liquid refractive index measurements using cavity in silicon via near-infrared interferometry
    Kim, Taeyeong
    Choi, Minwoo
    Lee, Bong Jae
    Lee, Jungchul
    SENSORS AND ACTUATORS A-PHYSICAL, 2025, 381
  • [27] Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region
    Daimon, Masahiko
    Masumura, Akira
    APPLIED OPTICS, 2007, 46 (18) : 3811 - 3820
  • [28] Refractive index of human whole blood with different types in the visible and near-infrared ranges
    Li, H
    Lin, L
    Xie, SS
    LASER-TISSUE INTERACTION XI: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, 2000, 3914 : 517 - 521
  • [29] NEAR-INFRARED FLUORESCENCE OF GREEN LEAVES
    MAYER, RJ
    INFRARED PHYSICS, 1965, 5 (01): : 7 - &
  • [30] Near-infrared II fluorescence imaging
    不详
    NATURE REVIEWS METHODS PRIMERS, 2024, 4 (01):