Evaluation of Pressure Bed Sensor for Automatic SAHS Screening

被引:32
|
作者
Guerrero Mora, Guillermina [1 ]
Kortelainen, Juha M. [2 ]
Palacios Hernandez, Elvia Ruth [3 ]
Tenhunen, Mirja [4 ]
Bianchi, Anna Maria [5 ]
Mendez, Martin O. [3 ]
机构
[1] Univ Autonoma San Luis Potosi, San Luis Potosi 78000, Mexico
[2] Valmistustekniikka Turvallisuustekniikka Tech Res, Tampere 33101, Finland
[3] Univ Autonoma San Luis Potosi, Fac Ciencias, San Luis Potosi 07360, Mexico
[4] Tampere Univ Hosp, Dept Clin Neurophysiol, Tampere 33521, Finland
[5] Politecn Milan, Dept Biomed Engn, I-20133 Milan, Italy
关键词
Polysomnography (PSG); pressure bed sensor (PBS); respiration monitoring; sleep apnea-hypopnea syndrome (SAHS); sleep monitoring; unattended portable monitor; unobtrusive measure; OBSTRUCTIVE SLEEP-APNEA; CHARGE SENSITIVE BED; AIR-FLOW; ELECTROCARDIOGRAM; PLETHYSMOGRAPHY; RESPIRATION; EVENTS; SCSB;
D O I
10.1109/TIM.2014.2366976
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We evaluate the performance of an unobtrusive sleep monitoring system in the detection of the sleep apnea-hypopnea syndrome (SAHS). The proposed system is a pressure bed sensor (PBS) that incorporates multiple pressure sensors into a bed mattress to measure several physiological signals of the sleeping subject: respiration; heart rate; and body movements. An automatic algorithm is developed to calculate a respiratory event index (REI). The recordings of 24 patients with suspected sleep problems are analyzed, and the results are compared with the gold standard methods; first with manual scoring of polysomnography to calculate the apnea-hypopnea index (AHI), and second with automatic detection of REI from the respiratory inductive plethysmography belts. The correlation coefficient between AHI and REI from PBS is up to 0.93. Evaluating the ability of PBS in the diagnosis of pathologic (AHI = 5) and nonpathologic (AHI < 5) subjects, we obtained a sensitivity, specificity, and accuracy of 100%, 92%, and 96%, respectively. To diagnose three levels of SAHS, mild, moderate, and severe, the Cohen's kappa value is 0.76. These findings support that PBS recording could provide a simple and unobtrusive method for detection of SAHS in home monitoring.
引用
收藏
页码:1935 / 1943
页数:9
相关论文
共 50 条
  • [31] Clinical evaluation of intraparenchymal spiegelberg pressure sensor
    Lang, JM
    Beck, J
    Zimmermann, M
    Seifert, V
    Raabe, A
    NEUROSURGERY, 2003, 52 (06) : 1455 - 1459
  • [32] Evaluation of a sensor for low interface pressure applications
    Ferguson-Pell, M
    Hagisawa, S
    Bain, D
    MEDICAL ENGINEERING & PHYSICS, 2000, 22 (09) : 657 - 663
  • [33] Customizable Pressure Sensor Array: Design and Evaluation
    Chen, Diliang
    Cai, Yi
    Huang, Ming-Chun
    IEEE SENSORS JOURNAL, 2018, 18 (15) : 6337 - 6344
  • [34] A miniature pressure sensor for blast event evaluation
    Wu, Nan
    Wang, Wenhui
    Tian, Ye
    Niezrecki, Christopher
    Wang, Xingwei
    SENSING TECHNOLOGIES FOR GLOBAL HEALTH, MILITARY MEDICINE, DISASTER RESPONSE, AND ENVIRONMENTAL MONITORING AND BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION VIII, 2011, 8029
  • [35] AUTOMATIC EXPERIMENTAL EVALUATION OF PRIMARY PRESSURE TRANSDUCER CHARACTERISTICS
    PSHENICHNIKOV, VV
    SKOBELEV, OP
    SOIFER, VA
    MEASUREMENT TECHNIQUES, 1978, 21 (06) : 764 - 765
  • [36] Automatic microassembly system for die level fabrication of MEMS pressure sensor
    Chen, Liguo
    Chen, Tao
    Sun, Lining
    Rong, Weibin
    ICIEA 2007: 2ND IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-4, PROCEEDINGS, 2007, : 1079 - 1083
  • [37] AUTOMATIC-MEASUREMENT OF INTRAOCULAR-PRESSURE WITH AN ELECTRONIC SENSOR TONOMETER
    DRAEGER, J
    HECHLER, B
    LEVEDAG, S
    WIRT, H
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1987, 190 (06) : 539 - 541
  • [38] A Study of Automatic Classification of Sleeping Position by a Pressure-sensitive Sensor
    Mineharu, Aya
    Kuwahara, Noriaki
    Morimoto, Kazunari
    2015 4TH INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION ICIEV 15, 2015,
  • [39] Automatic sensor evaluation in BMS commissioning of building refrigeration systems
    Wang, SW
    Wang, JB
    AUTOMATION IN CONSTRUCTION, 2002, 11 (01) : 59 - 73
  • [40] Opportunistic screening of atrial fibrillation by automatic blood pressure measurement in the community
    Omboni, Stefano
    Verberk, Willem J.
    BMJ OPEN, 2016, 6 (04):