Linshom respiratory monitoring device: a novel temperature-based respiratory monitor

被引:1
|
作者
Lerman, Jerrold [1 ,2 ]
Feldman, Doron [2 ]
Feldman, Ronen [3 ]
Moser, John [3 ]
Feldman, Leeshi [4 ]
Sathyamoorthy, Madhankumar [5 ]
Deitch, Kenneth [6 ]
Feldman, Uri [3 ]
机构
[1] Women & Childrens Hosp Buffalo, Dept Anesthesia, 219 Bryant St, Buffalo, NY 14209 USA
[2] SUNY Buffalo, Buffalo, NY USA
[3] Artep Inc, Ellicott City, MD USA
[4] Sackler Sch Med, Tel Aviv, Israel
[5] Univ Mississippi, Med Ctr, Dept Anesthesiol, Jackson, MS 39216 USA
[6] Thomas Jefferson Univ, Einstein Med Ctr, Dept Emergency Med, Philadelphia, PA 19107 USA
关键词
PULSE OXIMETRY; ACCURACY; APNEA; CAPNOGRAPHY; IMPEDANCE;
D O I
10.1007/s12630-016-0694-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We sought to develop a temperature-based respiratory instrument to measure respiration noninvasively outside critical care settings. Respiratory temperature profiles were recorded using a temperature-based noninvasive instrument comprised of three rapid responding medical-grade thermistors-two in close proximity to the mouth/nose (sensors) and one remote to the airway (reference). The effect of the gas flow rate on the amplitude of the tracings was determined. The temperature-based instrument, the Linshom Respiratory Monitoring Device (LRMD) was mounted to a face mask and positioned on a mannequin face. Respiratory rates of 5-40 breaths center dot min(-1) were then delivered to the mannequin face in random order using artificial bellows (IngMar Lung Model). Data from the sensors were collected and compared with the bellows rates using least squares linear regression and coefficient of determination. The investigators breathed at fixed rates of 0-60 breaths center dot min(-1) in synchrony with a metronome as their respiratory temperature profiles were recorded from sensors mounted to either a face mask or nasal prongs. The recordings were compared with a contemporaneously recorded sidestream capnogram from a CARESCAPE GEB450 Monitor. The extracted respiratory rates from the LRMD tracings and capnograms were compared using linear regression with a coefficient of determination and a Bland-Altman plot. The amplitude of the sensor tracings was independent of the oxygen flow rate. Respiratory rates from the new temperature-based sensor were synchronous and correlated identically with both the artificial bellows (r(2) = 0.9997) and the capnometer mounted to both the face mask and nasal prongs (r(2) = 0.99; bias = -0.17; 95% confidence interval, -2.15 to 1.8). Respiratory rates using the LRMD, a novel temperature-based respiratory instrument, were consistent with those using capnometry.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [1] Linshom respiratory monitoring device: a novel temperature-based respiratory monitor; [Le dispositif de monitorage respiratoire Linshom: un nouveau moniteur respiratoire basé sur la température]
    Lerman J.
    Feldman D.
    Feldman R.
    Moser J.
    Feldman L.
    Sathyamoorthy M.
    Deitch K.
    Feldman U.
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016, 63 (10): : 1154 - 1160
  • [2] A Novel Device for Monitoring Respiratory Rate as an Alternative to Capnography During Endoscopy: Linshom Thermodynamic Sensor
    Wadhwa, Vaibhav
    Feldman, Ronen
    Lopez, Rocio
    Vargo, John
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2017, 112 : S643 - S644
  • [3] Non-invasive continuous respiratory monitoring using temperature-based sensors
    Daniel E. Hurtado
    Angel Abusleme
    Javier A. P. Chávez
    Journal of Clinical Monitoring and Computing, 2020, 34 : 223 - 231
  • [4] Non-invasive continuous respiratory monitoring using temperature-based sensors
    Hurtado, Daniel E.
    Abusleme, Angel
    Chavez, Javier A. P.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (02) : 223 - 231
  • [5] Linshom thermodynamic sensor is a reliable alternative to capnography for monitoring respiratory rate
    David Preiss
    Benjamin A. Drew
    James Gosnell
    Bhavani S. Kodali
    James H. Philip
    Richard D. Urman
    Journal of Clinical Monitoring and Computing, 2018, 32 : 133 - 140
  • [6] Linshom thermodynamic sensor is a reliable alternative to capnography for monitoring respiratory rate
    Preiss, David
    Drew, Benjamin A.
    Gosnell, James
    Kodali, Bhavani S.
    Philip, James H.
    Urman, Richard D.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (01) : 133 - 140
  • [7] A DEVICE FOR MONITORING VENTILATION DURING ANESTHESIA - THE PARATRACHEAL AUDIBLE RESPIRATORY MONITOR
    ELDOR, J
    GUEDJ, P
    ADLER, D
    MALHER, Y
    OLSHWANG, D
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1990, 9 (01): : 95 - 98
  • [8] A respiratory monitoring device based on clavicular motion
    Pitts, D. G.
    Patel, M. K.
    Lang, P-O
    Sinclair, A. J.
    Aspinall, R.
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (08) : N51 - N61
  • [9] Validation of a novel respiratory rate monitor based on exhaled humidity
    Niesters, M.
    Mahajan, R.
    Olofsen, E.
    Boom, M.
    Garcia del Valle, S.
    Aarts, L.
    Dahan, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (06) : 981 - 989
  • [10] Evaluation of novel respiratory sensor in neonatal respiratory monitoring
    Vennard, Hannah
    Miller, Jennifer
    Cowan, Catriona
    Meredith, Osian
    Patel, Neil
    Davies, Philip
    Langley, Ross
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64