Ten-year outcome after aortic valve replacement with the freestyle stentless bioprosthesis

被引:88
|
作者
Bach, DS
Kon, ND
Dumesnil, JG
Sintek, CF
Doty, DB
机构
[1] Univ Michigan, Div Cardiol, Dept Med, Ann Arbor, MI 48109 USA
[2] Wake Forest Univ, Sch Med, Dept Surg, Sect Cardiothorac Surg, Winston Salem, NC 27109 USA
[3] Univ Laval, Dept Med, Div Cardiol, Ste Foy, PQ G1K 7P4, Canada
[4] Kaiser Permanente Hosp, Dept Cardiac Surg, Los Angeles, CA USA
[5] LDS Hosp, Salt Lake City, UT USA
来源
ANNALS OF THORACIC SURGERY | 2005年 / 80卷 / 02期
关键词
D O I
10.1016/j.athoracsur.2005.03.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Stentless aortic bioprostheses offer excellent hemodynamics and potentially improved durability compared with other bioprostheses. The present report describes the clinical and hemodynamic outcomes for the Freestyle aortic root bioprosthesis in a large, multicenter cohort prospectively followed up for 10 years. Methods. A total of 725 patients at 8 centers in North America (668 [92%] aged more than 60 years) were followed up prospectively after aortic valve replacement with the Freestyle stentless bioprosthesis. Implant technique was subcoronary in 509, total root in 178, and root inclusion in 38. Follow-up was 4,488 patient-years (mean 6.2 years/patient). Results. For subcoronary, full root, and root inclusion groups, 10-year actuarial freedom from structural valve deterioration was 97.0% +/- 2.2%, 96.0% +/- 4.5%, and 90.9% +/- 11.2%, respectively; and actuarial freedom from reoperation was 91.7% +/- 3.5%, 92.3% +/- 6.0%, and 92.0% +/- 10.7%, respectively. Mean pressure gradient at 10 years was 8.9 +/- 7.9 mm Hg for subcoronary, 7.0 +/- 4.1 mm Hg for full root, and 10.0 +/- 11.1 mm Hg for root inclusion groups; effective orifice area was 1.6 +/- 0.5 cm(2), 1.6 +/- 0.6 cm(2), and 1.7 +/- 0.5 cm(2), respectively. Freedom from moderate or more aortic regurgitation at 10 years was good for all three implant groups, but slightly higher for full root (97.7% +/- 1.6%) compared with subcoronary (87.2% +/- 2.8%) patients (p < 0.005). Conclusions. The Freestyle stentless aortic root bioprosthesis is a versatile option for aortic valve replacement. Measures of clinical outcomes and prosthesis durability remain excellent through 10 years.
引用
收藏
页码:480 / 487
页数:8
相关论文
共 50 条
  • [41] Aortic valve replacement with a Cryolife O'Brien stentless bioprosthesis
    Campos, Vicente
    Adrio, Belen
    Estevez, Francisco
    Mosquera, Victor X.
    Perez, Javier
    Cuenca, Jose J.
    Herrera, Jose M.
    Valle, Jose V.
    Portela, Francisco
    Rodriguez, Fernando
    Juffe, Alberto
    REVISTA ESPANOLA DE CARDIOLOGIA, 2007, 60 (01): : 45 - 50
  • [42] Structural Valve Deterioration After Aortic Valve Replacement with Medtronic Freestyle Stentless Porcine Aortic Root Bioprostheses
    Nishida, Hidefumi
    Komiya, Tatsuhiko
    Sakaguchi, Genichi
    Shimamoto, Takeshi
    JOURNAL OF CARDIAC SURGERY, 2014, 29 (01) : 22 - 25
  • [43] Aortic valve replacement with the Cryolife-OBrien stentless aortic bioprosthesis: five-year experience
    Martinovic, I
    Farah, I
    Everlien, M
    Knez, I
    Greve, H
    Vogt, P
    JOURNAL OF CARDIOVASCULAR SURGERY, 2004, 45 (06): : 557 - 563
  • [44] Proximal Thoracic Aortic Replacement for Aneurysmal Disease Using the Freestyle Stentless Bioprosthesis: A 10-Year Experience
    Pagni, Sebastian
    Slater, A. David
    Trivedi, Jaimin R.
    Williams, Matthew
    Austin, Erle
    Mascio, Christopher E.
    Ganzel, Brian L.
    ANNALS OF THORACIC SURGERY, 2011, 92 (03): : 873 - 879
  • [45] A Technique of Aortic Annulus Enlargement With a Freestyle Stentless Bioprosthesis
    Bical, Olivier M.
    Nutu, Ovidiu
    Deleuze, Philippe
    ANNALS OF THORACIC SURGERY, 2012, 93 (02): : 680 - 681
  • [46] Aortic root replacement with Freestyle stentless valve for complex aortic root infection
    Fukui, T
    Suehiro, S
    Shibata, T
    Hattori, K
    Hirai, H
    Aoyama, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (01): : 200 - 203
  • [47] Eight-year results after aortic valve replacement with the CryoLife-O'Brien Stentless Aortic Porcine Bioprosthesis
    Martinovic, I
    Farah, I
    Everlien, M
    Lindemann, S
    Knez, I
    Wittlinger, T
    Greve, H
    Vogt, P
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (03): : 777 - 782
  • [48] Impact of implant technique following freestyle stentless aortic valve replacement
    Bach, DS
    Cartier, PC
    Kon, ND
    Johnson, KG
    Deeb, GM
    Doty, DB
    ANNALS OF THORACIC SURGERY, 2002, 74 (04): : 1107 - 1113
  • [49] TECHNIQUE OF AORTIC-VALVE REPLACEMENT WITH THE EDWARDS STENTLESS AORTIC BIOPROSTHESIS 2500
    KONERTZ, W
    WEYAND, M
    SIDIROPOULOS, A
    SCHWAMMENTHAL, E
    BREITHARDT, G
    SCHELD, HH
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (05) : 274 - 277
  • [50] 12-year results of aortic valve replacement with the Cryolife O'Brien stentless bioprosthesis
    Pavoni, D.
    Badano, L. P.
    Ius, F.
    Musumeci, S. F.
    Vedranin, I.
    Frassani, R.
    Mazzaro, E.
    Livi, U.
    EUROPEAN HEART JOURNAL, 2006, 27 : 733 - 733