Ten-year outcome after aortic valve replacement with the freestyle stentless bioprosthesis

被引:88
|
作者
Bach, DS
Kon, ND
Dumesnil, JG
Sintek, CF
Doty, DB
机构
[1] Univ Michigan, Div Cardiol, Dept Med, Ann Arbor, MI 48109 USA
[2] Wake Forest Univ, Sch Med, Dept Surg, Sect Cardiothorac Surg, Winston Salem, NC 27109 USA
[3] Univ Laval, Dept Med, Div Cardiol, Ste Foy, PQ G1K 7P4, Canada
[4] Kaiser Permanente Hosp, Dept Cardiac Surg, Los Angeles, CA USA
[5] LDS Hosp, Salt Lake City, UT USA
来源
ANNALS OF THORACIC SURGERY | 2005年 / 80卷 / 02期
关键词
D O I
10.1016/j.athoracsur.2005.03.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Stentless aortic bioprostheses offer excellent hemodynamics and potentially improved durability compared with other bioprostheses. The present report describes the clinical and hemodynamic outcomes for the Freestyle aortic root bioprosthesis in a large, multicenter cohort prospectively followed up for 10 years. Methods. A total of 725 patients at 8 centers in North America (668 [92%] aged more than 60 years) were followed up prospectively after aortic valve replacement with the Freestyle stentless bioprosthesis. Implant technique was subcoronary in 509, total root in 178, and root inclusion in 38. Follow-up was 4,488 patient-years (mean 6.2 years/patient). Results. For subcoronary, full root, and root inclusion groups, 10-year actuarial freedom from structural valve deterioration was 97.0% +/- 2.2%, 96.0% +/- 4.5%, and 90.9% +/- 11.2%, respectively; and actuarial freedom from reoperation was 91.7% +/- 3.5%, 92.3% +/- 6.0%, and 92.0% +/- 10.7%, respectively. Mean pressure gradient at 10 years was 8.9 +/- 7.9 mm Hg for subcoronary, 7.0 +/- 4.1 mm Hg for full root, and 10.0 +/- 11.1 mm Hg for root inclusion groups; effective orifice area was 1.6 +/- 0.5 cm(2), 1.6 +/- 0.6 cm(2), and 1.7 +/- 0.5 cm(2), respectively. Freedom from moderate or more aortic regurgitation at 10 years was good for all three implant groups, but slightly higher for full root (97.7% +/- 1.6%) compared with subcoronary (87.2% +/- 2.8%) patients (p < 0.005). Conclusions. The Freestyle stentless aortic root bioprosthesis is a versatile option for aortic valve replacement. Measures of clinical outcomes and prosthesis durability remain excellent through 10 years.
引用
收藏
页码:480 / 487
页数:8
相关论文
共 50 条
  • [21] Medtronic stentless Freestyle® porcine aortic valve replacement
    Ennker, J.
    Albert, A.
    Florath, I.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 366 - +
  • [22] 7-years of aortic valve replacement with the freestyle stentless bioprosthesis in 503 elderly patients: determinants of outcome and quality of life
    Ennker, J
    Rosendahl, U
    Ennker, IC
    Bauer, S
    Dalladaku, F
    Florath, I
    EUROPEAN HEART JOURNAL, 2004, 25 : 595 - 595
  • [23] AORTIC-VALVE REPLACEMENT WITH STENTLESS PORCINE AORTIC BIOPROSTHESIS
    DAVID, TE
    POLLICK, C
    BOS, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 99 (01): : 113 - 118
  • [24] Ten-Year Follow Up after Prospectively Randomized Evaluation of Stentless versus Conventional Xenograft Aortic Valve Replacement
    Lehmann, Sven
    Walther, Thomas
    Kempfert, Joerg
    Leontyev, Sergey
    Bakhtiary, Farhad
    Rastan, Ardawan
    Mohr, Friedrich W.
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (06): : 681 - 687
  • [25] AORTIC-VALVE REPLACEMENT WITH A STENTLESS PORCINE BIOPROSTHESIS
    GOLDMAN, BS
    DAVID, TE
    DELRIZZO, D
    YACOUB, M
    ALDRETE, V
    JOYNER, C
    MURPHY, P
    RAKOWSKI, H
    MCCALLUM, L
    CIRCULATION, 1994, 90 (04) : 310 - 310
  • [26] STENTLESS PORCINE BIOPROSTHESIS FOR AORTIC-VALVE REPLACEMENT
    GOLDMAN, BS
    DAVID, TE
    DELRIZZO, DF
    SEVER, J
    BOS, J
    JOURNAL OF CARDIOVASCULAR SURGERY, 1994, 35 (06): : 105 - 110
  • [27] Aortic valve replacement with the Freestyle stentless bioprosthesis with respect to spacial orientation of patient coronary ostia - Commentary
    Westaby, S
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (06): : 1192 - 1193
  • [28] Eight-year results of aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis - Discussion
    Ring, WS
    Kon, ND
    ANNALS OF THORACIC SURGERY, 2002, 73 (06): : 1821 - 1821
  • [29] Sutureless aortic valve replacement in stentless bioprosthesis failure
    Kim, Jae Hyun
    Kim, Jae-Bum
    Choi, Sae Young
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (06) : 801 - 802
  • [30] Predicted patient outcome after aortic valve replacement with medtronic stentless freestyle bioprostheses - Meeting discussion
    Bolling, Steven F.
    Kappetein, Pieter
    Modry, Dennis
    JOURNAL OF HEART VALVE DISEASE, 2007, 16 (04): : 429 - 429