AGREEMENT AND REPRODUCIBILITY OF RETINAL PIGMENT EPITHELIAL DETACHMENT VOLUMETRIC MEASUREMENTS THROUGH OPTICAL COHERENCE TOMOGRAPHY

被引:11
|
作者
Ho, Joseph [1 ]
Adhi, Mehreen [1 ]
Baumal, Caroline [1 ]
Liu, Jonathan [2 ]
Fujimoto, James G. [2 ]
Duker, Jay S. [1 ]
Waheed, Nadia K. [1 ]
机构
[1] Tufts Med Ctr, Dept Ophthalmol, New England Eye Ctr, Boston, MA USA
[2] MIT, Dept Elect Engn & Comp Sci, Elect Res Lab, Cambridge, MA 02139 USA
关键词
automated RPED volume; intraclass coefficient; MACULAR DEGENERATION; AUTOMATIC SEGMENTATION; DRUSEN;
D O I
10.1097/IAE.0000000000000355
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the agreement and reproducibility of retinal pigment epithelial detachment (RPED) volumetric measurements using a commercially available optical coherence tomography software available for the Zeiss Cirrus HD-OCT. Methods: Twelve eyes of 10 patients with a diagnosis of neovascular age-related macular degeneration with RPED, seen at the New England Eye Center between October 2012 and December 2012, were enrolled in the study. Three separate scans per affected eye were obtained using the "Macular Cube 512 x 128" protocol. "Retinal pigment epithelial (RPE) elevation analysis" software was used to measure RPED volumes in the central 3-mm and 5-mm circles by calculating the volume between the "RPE fit" and "true RPE" lines. All 128 raster scans for each eye were exported into the AMIRA software for manual segmentation of RPED volumes in the central 3-mm and 5-mm circles. Interscan reproducibility and manual-to-automated agreement were assessed by intraclass correlation coefficient. Incidence of automated segmentation line error for both RPE fit and true RPE lines in the central 1 mm region was calculated. Results: Average RPED volumes through automated segmentation software were 0.14 mm(3) and 0.21 mm(3) in the central 3-mm and 5-mm circles, respectively. Manual segmentation yielded average RPED volumes of 0.50 mm(3) in the 3-mm circles and 0.92 mm(3) in the 5-mm circles. Manual segmentation yielded significantly greater RPED volumes compared with automated measurements (P < 0.05). Intraclass correlation coefficients across the 3 automated measurements were 0.954 and 0.983 for volume in the 3-mm and 5-mm circles, respectively. Intraclass correlation coefficients between the manual and automatic volumes were 0.296 and 0.337 for the 3-mm and 5-mm circles, respectively. In the central 1 mm region, 11 of the 12 scans had breakdown in RPE fit line, whereas 8 of the 12 scans showed true RPE line breakdown. Conclusion: Automated "RPED elevation" software demonstrated high interscan reproducibility. However, it showed low agreement with manual measurements from high rates of segmentation line breakdown, especially at the level of the RPE fit line (91.7%). Manual measurements resulted in greater volumes compared with automated measurements.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 50 条
  • [41] Optical coherence tomography of the neurosensory retina in rhegmatogenous retinal detachment
    Hagimura, N
    Suto, K
    Iida, T
    Kishi, S
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (02) : 186 - 190
  • [42] Volumetric Analysis of Vascularized Serous Pigment Epithelial Detachment Progression in Neovascular Age-Related Macular Degeneration Using Optical Coherence Tomography Angiography
    Au, Adrian
    Hou, Kirk
    Davila, Juan Pablo
    Gunnemann, Frederic
    Fragiotta, Serena
    Arya, Malvika
    Sacconi, Riccardo
    Pauleikhoff, Daniel
    Querques, Giuseppe
    Waheed, Nadia
    Freund, K. Bailey
    Sadda, SriniVas
    Sarraf, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (10) : 3310 - 3319
  • [43] Repeatability and Reproducibility of Retinal Thickness Measurements in Diabetic Patients with Spectral Domain Optical Coherence Tomography
    Fiore, Tito
    Androudi, Sofia
    Iaccheri, Barbara
    Lupidi, Marco
    Fabrizio, Giansanti
    Fruttini, Daniela
    Biondi, Laura
    Cagini, Carlo
    CURRENT EYE RESEARCH, 2013, 38 (06) : 674 - 679
  • [44] Repeatability and Reproducibility of Spectral-Domain Optical Coherence Tomography Measurements of Retinal Thickness in Rats
    Yang, Ji Ho
    Yu, Seung-Young
    Kim, Tae Gi
    Seo, Kyung Hoon
    Kwak, Hyung Woo
    CURRENT EYE RESEARCH, 2016, 41 (10) : 1346 - 1352
  • [45] Reproducibility of Spectral-Domain Optical Coherence Tomography Total Retinal Thickness Measurements in Mice
    Gabriele, Michelle L.
    Ishikawa, Hiroshi
    Schuman, Joel S.
    Bilonick, Richard A.
    Kim, Jongsick
    Kagemann, Larry
    Wollstein, Gadi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6519 - 6523
  • [46] RETINAL-PIGMENT EPITHELIAL DETACHMENT
    YANNUZZI, LA
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1989, 12 (11): : 761 - 774
  • [47] PIGMENT EPITHELIAL RETINAL-DETACHMENT
    LALONDE, G
    TARDIF, Y
    MALENFANT, M
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1982, 17 : 43 - 43
  • [48] Reproducibility of Retinal Thickness Measurements on Normal and Pathologic Eyes by Different Optical Coherence Tomography Instruments
    Giani, Andrea
    Cigada, Mario
    Choudhry, Netan
    Deiro, Antonio Peroglio
    Oldani, Marta
    Pellegrini, Marco
    Invernizzi, Alessandro
    Duca, Piergiorgio
    Miller, Joan W.
    Staurenghi, Giovanni
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (06) : 815 - 824
  • [49] Retinal pigment epithelial detachment in sarcoidosis
    Salchow, Daniel J.
    Weiss, Michael J.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2006, 14 (04) : 245 - 248
  • [50] OPTICAL COHERENCE TOMOGRAPHY BIOMARKERS FOR REDUCTION OF DRUSENOID PIGMENT EPITHELIUM DETACHMENT
    Kim, Mirinae
    Lee, Yeo Jin
    Park, Wookyung
    Park, Young-Gun
    Park, Young-Hoon
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (02): : 402 - 408