AGREEMENT AND REPRODUCIBILITY OF RETINAL PIGMENT EPITHELIAL DETACHMENT VOLUMETRIC MEASUREMENTS THROUGH OPTICAL COHERENCE TOMOGRAPHY

被引:11
|
作者
Ho, Joseph [1 ]
Adhi, Mehreen [1 ]
Baumal, Caroline [1 ]
Liu, Jonathan [2 ]
Fujimoto, James G. [2 ]
Duker, Jay S. [1 ]
Waheed, Nadia K. [1 ]
机构
[1] Tufts Med Ctr, Dept Ophthalmol, New England Eye Ctr, Boston, MA USA
[2] MIT, Dept Elect Engn & Comp Sci, Elect Res Lab, Cambridge, MA 02139 USA
关键词
automated RPED volume; intraclass coefficient; MACULAR DEGENERATION; AUTOMATIC SEGMENTATION; DRUSEN;
D O I
10.1097/IAE.0000000000000355
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the agreement and reproducibility of retinal pigment epithelial detachment (RPED) volumetric measurements using a commercially available optical coherence tomography software available for the Zeiss Cirrus HD-OCT. Methods: Twelve eyes of 10 patients with a diagnosis of neovascular age-related macular degeneration with RPED, seen at the New England Eye Center between October 2012 and December 2012, were enrolled in the study. Three separate scans per affected eye were obtained using the "Macular Cube 512 x 128" protocol. "Retinal pigment epithelial (RPE) elevation analysis" software was used to measure RPED volumes in the central 3-mm and 5-mm circles by calculating the volume between the "RPE fit" and "true RPE" lines. All 128 raster scans for each eye were exported into the AMIRA software for manual segmentation of RPED volumes in the central 3-mm and 5-mm circles. Interscan reproducibility and manual-to-automated agreement were assessed by intraclass correlation coefficient. Incidence of automated segmentation line error for both RPE fit and true RPE lines in the central 1 mm region was calculated. Results: Average RPED volumes through automated segmentation software were 0.14 mm(3) and 0.21 mm(3) in the central 3-mm and 5-mm circles, respectively. Manual segmentation yielded average RPED volumes of 0.50 mm(3) in the 3-mm circles and 0.92 mm(3) in the 5-mm circles. Manual segmentation yielded significantly greater RPED volumes compared with automated measurements (P < 0.05). Intraclass correlation coefficients across the 3 automated measurements were 0.954 and 0.983 for volume in the 3-mm and 5-mm circles, respectively. Intraclass correlation coefficients between the manual and automatic volumes were 0.296 and 0.337 for the 3-mm and 5-mm circles, respectively. In the central 1 mm region, 11 of the 12 scans had breakdown in RPE fit line, whereas 8 of the 12 scans showed true RPE line breakdown. Conclusion: Automated "RPED elevation" software demonstrated high interscan reproducibility. However, it showed low agreement with manual measurements from high rates of segmentation line breakdown, especially at the level of the RPE fit line (91.7%). Manual measurements resulted in greater volumes compared with automated measurements.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 50 条
  • [1] Reproducibility and Agreeability of Automated Retinal Pigment Epithelial Detachment Volumetric Measurements via Spectral Domain Optical Coherence Tomography
    Ho, Joseph
    Adhi, Mehreen
    Cole, Emily
    Liu, Jonathan
    Fujimoto, James
    Duker, Jay
    Waheed, Nadia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [2] Optical coherence tomography angiography artifacts in retinal pigment epithelial detachment
    Louzada, Ricardo N.
    de Carlo, Talisa E.
    Adhi, Mehreen
    Novais, Eduardo A.
    Durbin, Mary K.
    Cole, Emily
    Lane, Mark
    Moghimi, Omid
    Arya, Malvika
    Bonini Filho, Marco
    Witkin, Andre J.
    Baumal, Caroline R.
    Avila, Marcos
    Duker, Jay S.
    Waheed, Nadia K.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2017, 52 (04): : 419 - 424
  • [3] Retinal pigment epithelial detachment associated with retinal pigment epithelium thinning revealed by optical coherence tomography
    Satoko Notani
    Ryusaburo Mori
    Mitsuko Yuzawa
    Akiyuki Kawamura
    Japanese Journal of Ophthalmology, 2015, 59 : 305 - 311
  • [4] Retinal pigment epithelial detachment associated with retinal pigment epithelium thinning revealed by optical coherence tomography
    Notani, Satoko
    Mori, Ryusaburo
    Yuzawa, Mitsuko
    Kawamura, Akiyuki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2015, 59 (05) : 305 - 311
  • [5] Optical Coherence Tomography Angiography of Pigment Epithelial Detachment
    Veronese, Chiara
    Morara, Mariachiara
    Melucci, Martina
    Tassi, Filippo
    Balducci, Nicole
    Ciardella, Antonio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [6] Automated Characterization of Pigment Epithelial Detachment by Optical Coherence Tomography
    Lee, Sun Young
    Stetson, Paul F.
    Ruiz-Garcia, Humberto
    Heussen, Florian M.
    Sadda, SriniVas R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) : 164 - 170
  • [7] Optical coherence tomography appearance of "drusenoid" pigment epithelial detachment
    Emfietzoglou, L
    Grigoropoulos, W
    Kipioti, A
    Alimisi, S
    Theodossiadis, PG
    Theodossiadis, GP
    OPHTHALMIC SURGERY LASERS & IMAGING, 2005, 36 (02): : 147 - 150
  • [8] OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY TO ASSESS PIGMENT EPITHELIAL DETACHMENT
    Veronese, Chiara
    Maiolo, Chiara
    Morara, Mariachiara
    Armstrong, Grayson W.
    Ciardella, Antonio P.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (03): : 645 - 650
  • [9] Central serous chorioretinopathy with retinal pigment epithelial detachment: Evaluation with optical coherence tomography.
    Parmar, DN
    Stanga, PE
    Ahuja, RM
    Vingerling, JR
    Bird, AC
    Hamilton, AMP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S685 - S685
  • [10] Method for artificially degrading the signal from Optical Coherence Tomography cube to assess variability in retinal pigment epithelial detachment volumetric measurement
    Kubach, Sophie
    De Sisternes, Luis
    Lewis, Warren
    Gregori, Giovanni
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (11)