Effects of negative DC pre-stressing on positive impulse breakdown characteristics of conductor-rod gaps

被引:2
|
作者
Gourgoulis, DE [1 ]
Mikropoulos, PN [1 ]
Stassinopoulos, CA [1 ]
Yakinthos, CG [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Elect & Comp Engn, High Voltage Lab, Thessaloniki 54124, Greece
关键词
D O I
10.1049/ip-smt:20045006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The positive impulse breakdown behaviour of conductor-rod gaps 50cm in length is investigated while negative DC voltages pre-stress the gap. Breakdown voltage and time to breakdown variations are discussed in terms of the parameters influencing the discharge mechanism such as the gap geometry, the amplitude of the pre-stress negative DC voltage applied at the rod, the waveshape of the applied impulse voltage at the conductor and the variation of absolute humidity. It is shown that pre-stressing, by producing sufficient DC coronas at both electrodes, results in a significant increase in the breakdown voltage. There is a threshold value of the pre-stress DC voltage above which the gap factor against breakdown may double its value. Both absolute humidity and pre-stressing affect, in a combined way, the dielectric strength of the gaps.
引用
收藏
页码:155 / 160
页数:6
相关论文
共 42 条
  • [31] The breakdown of a tower-line clearance under impulse voltages pre-stressed by a negative DC voltage
    Stassinopoulos, CA
    Yakinthos, CG
    GASEOUS DIELECTRICS IX, 2001, : 535 - 540
  • [32] PRE-BREAKDOWN DISCHARGES IN ROD-PLANE GAPS IN SF6 UNDER POSITIVE SWITCHING IMPULSES
    ANIS, H
    SRIVASTAVA, KD
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1981, 16 (06): : 552 - 563
  • [33] Switching Impulse Breakdown Characteristics of Large Sphere-plane Air Gaps compared with Rod-plane Air Gap
    Chen, She
    Zeng, Rong
    Zhuang, Chijie
    Yu, Zhanqing
    He, Jinliang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (03) : 839 - 844
  • [34] Impulse partial discharge and breakdown characteristics of rod-plane gaps in N2/SF6 gas mixtures
    Saitoh, H
    Morita, K
    Kikkawa, T
    Hayakawa, N
    Okubo, H
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (04) : 544 - 550
  • [35] Impulse partial discharge and breakdown characteristics of rod-plane gaps in N2/SF6 gas mixtures
    Saitoh, H
    Morita, K
    Kikkawa, T
    Kato, K
    Hayakawa, N
    Okubo, H
    2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 397 - 400
  • [36] Computation of breakdown voltage of long rod-plane air gaps in large temperature and humidity range under positive standard switching impulse voltage
    Ge, Xing
    Ding, Yujian
    Yao, Xiuyuan
    Lv, Fangcheng
    Yang, Bingxue
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 187
  • [37] BREAKDOWN PHENOMENA IN SF6 AND VERY INHOMOGENEOUS LARGE ROD-PLANE GAPS UNDER 50 HZ-AC AND POSITIVE IMPULSE VOLTAGES
    ZWICKY, M
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (03): : 317 - 324
  • [38] IMPULSE BREAKDOWN AND CORONA CHARACTERISTICS FOR ROD-PLANE GAPS IN MIXTURES OF SF6 AND NITROGEN WITH LESS THAN 1% OF SF6 CONTENT.
    Yializis, A.
    Malik, N.H.
    Qureshi, A.H.
    Kuffel, E.
    1979,
  • [39] IMPULSE BREAKDOWN AND CORONA CHARACTERISTICS FOR ROD-PLANE GAPS IN MIXTURES OF SF6 AND NITROGEN WITH LESS THAN 1-PERCENT OF SF6 CONTENT
    YIALIZIS, A
    MALIK, NH
    QURESHI, AH
    KUFFEL, E
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (05): : 1832 - 1840
  • [40] Computational and Experimental Study of Time-Averaged Characteristics of Positive and Negative DC Corona Discharges in Point-Plane Gaps in Atmospheric Air
    Ferreira, Nuno G. C.
    Almeida, Pedro G. C.
    Benilov, Mikhail S.
    Panarin, Victor A.
    Skakun, Victor S.
    Tarasenko, Victor F.
    Naidis, George V.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2020, 48 (12) : 4080 - 4088