Effects of negative DC pre-stressing on positive impulse breakdown characteristics of conductor-rod gaps

被引:2
|
作者
Gourgoulis, DE [1 ]
Mikropoulos, PN [1 ]
Stassinopoulos, CA [1 ]
Yakinthos, CG [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Elect & Comp Engn, High Voltage Lab, Thessaloniki 54124, Greece
关键词
D O I
10.1049/ip-smt:20045006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The positive impulse breakdown behaviour of conductor-rod gaps 50cm in length is investigated while negative DC voltages pre-stress the gap. Breakdown voltage and time to breakdown variations are discussed in terms of the parameters influencing the discharge mechanism such as the gap geometry, the amplitude of the pre-stress negative DC voltage applied at the rod, the waveshape of the applied impulse voltage at the conductor and the variation of absolute humidity. It is shown that pre-stressing, by producing sufficient DC coronas at both electrodes, results in a significant increase in the breakdown voltage. There is a threshold value of the pre-stress DC voltage above which the gap factor against breakdown may double its value. Both absolute humidity and pre-stressing affect, in a combined way, the dielectric strength of the gaps.