Status of the XMIS x-ray backscatter radiography land mine detection system

被引:0
|
作者
Dugan, ET [1 ]
Jacobs, AM [1 ]
Su, Z [1 ]
Houssay, L [1 ]
Ekdahl, D [1 ]
机构
[1] Univ Florida, Gainesville, FL 32611 USA
关键词
land mine detection; Compton backscatter; x-ray imaging; confirmation sensor;
D O I
10.1117/12.485860
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
An X-ray mine imaging system (XMIS) that uses a new form of backscatter x-ray radiography developed at the University of Florida was successfully field-tested at Fort A.P. Hill, Virginia in October, 2001. The XMIS obtained high quality images of both AP and AT mines on several of the Fort A.P. Hill test lanes. For high resolution imaging at a power level of 750 watts, total time for scanning and for processed image acquisition was about 60 s for a 0.5 m x 0.5 m area. The very good imaging results obtained from the initial field tests at Fort Hill with the XMIS demonstrate the excellent capabilities of this system as a confirmation sensor for land mine detection. These initial field tests showed that some fairly simple modifications could significantly improve the performance of the XMIS. The total cost of components for an XMIS field demonstration system that includes these modifications is about $60 K and includes about $24 K for the x-ray generator and about $16 K for the specially-made detector assemblies. Further field-testing of the XMIS needs to be performed, but this should be done following implementation of the indicated modifications. With the modifications, high resolution scanning of a 0.5 m x 0.5 m area can be done in 20 to 30 seconds at a power level of 300 to 400 watts.
引用
收藏
页码:34 / 44
页数:11
相关论文
共 50 条
  • [21] X-ray radiography
    Ooka, Norikazu
    Ishii, Toshimitsu
    Keikinzoku Yosetsu/Journal of Light Metal Welding and Construction, 1998, 36 (04):
  • [22] An adapted Modulation Transfer Function for X-ray backscatter Radiography by Selective Detection - art. no. 670614
    Sabri, Nissia
    Dugan, Edward T.
    Jacobs, Alan M.
    Shedlock, Daniel
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS IX, 2007, 6706 : 70614 - 70614
  • [23] Suitability of simulated land mines for detection measurements using x-ray lateral migration radiography
    Wells, CJ
    Su, Z
    Allard, A
    Salazar, S
    Dugan, E
    Jacobs, A
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS V, PTS 1 AND 2, 2000, 4038 : 578 - 589
  • [24] Landmine detection using backscattered x-ray radiography
    Wehlburg, JC
    Jacobs, J
    Shope, SL
    Lockwood, GJ
    Selph, MM
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS, 1999, 3769 : 149 - 154
  • [25] Bomb detection using backscattered x-ray radiography
    Wehlburg, JC
    Jacobs, J
    Shope, SL
    Lockwood, GJ
    Selph, MM
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 136 - 141
  • [26] Development and optimization of a backscatter X-ray detection system based on pencil beam scanning
    Park, Jaehyun
    An, Geunyoung
    Song, Gyohyeok
    Kim, Wonku
    Kim, Junhyeok
    Lim, Kyung Taek
    Hwang, Jisung
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1063
  • [27] A New Calibration Method for Backscatter Signal in a Side Beam X-ray Detection System
    Chen, JiaMin
    Li, Weijiao
    Shen, Tianming
    Chang, Qingqing
    ELECTRONICS, MECHATRONICS AND AUTOMATION III, 2014, 666 : 288 - +
  • [28] X-RAY RADIOGRAPHY WITH X-RAY DIFFRACTION EQUIPMENT
    CLIFTON, HE
    JOURNAL OF SEDIMENTARY PETROLOGY, 1966, 36 (02): : 620 - &
  • [29] X-ray backscatter imaging
    Dinca, Dan-Cristian
    Schubert, Jeffrey R.
    Callerame, J.
    OPTICS AND PHOTONICS IN GLOBAL HOMELAND SECURITY IV, 2008, 6945
  • [30] X-RAY BACKSCATTER IMAGING
    TOWE, BC
    JACOBS, AM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (09) : 646 - 654