Coordinated Optimization of Cooling and IT Power in Data Centers

被引:11
|
作者
Samadiani, Emad [1 ]
Amur, Hrishikesh
Krishnan, Bhavani [2 ]
Joshi, Yogendra [1 ]
Schwan, Karsten [2 ]
机构
[1] Georgia Inst Technol, GW Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Coll Comp, Atlanta, GA 30332 USA
关键词
air conditioning; computer centres; cooling; power consumption; thermal management (packaging); ROBUST DESIGN;
D O I
10.1115/1.4001858
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Concurrency and exchanging design knowledge among thermal and IT management are required to achieve an energy efficient operational data center. In this paper, a design approach is presented to bring adaptability and concurrency for coordinated minimization of cooling and IT power consumption in data centers. The presented approach is centered on a proper orthogonal decomposition based reduced order thermal modeling approach, and power profiling of the IT equipment to identify the optimal parameters of the air cooling systems along with optimal dynamic workload distribution among the servers. The method is applied to a data center cell with different rack and server architectures. The results show that the design approach results in 12-70% saving in the total energy consumption of the data center cell for various scenarios, compared with a baseline design. [DOI: 10.1115/1.4001858]
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Loosely coupled coordinated management in virtualized data centers
    Sanjay Kumar
    Vanish Talwar
    Vibhore Kumar
    Parthasarathy Ranganathan
    Karsten Schwan
    Cluster Computing, 2011, 14 : 259 - 274
  • [42] Loosely coupled coordinated management in virtualized data centers
    Kumar, Sanjay
    Talwar, Vanish
    Kumar, Vibhore
    Ranganathan, Parthasarathy
    Schwan, Karsten
    CLUSTER COMPUTING-THE JOURNAL OF NETWORKS SOFTWARE TOOLS AND APPLICATIONS, 2011, 14 (03): : 259 - 274
  • [43] Airflow optimization in data centers
    Energy Engineering Lead Syserco Inc., United States
    Energy Eng, 3 (33-54): : 33 - 54
  • [44] Model-driven coordinated management of data centers
    Mukherjee, Tridib
    Banerjee, Ayan
    Varsamopoulos, Georgios
    Gupta, Sandeep K. S.
    COMPUTER NETWORKS, 2010, 54 (16) : 2869 - 2886
  • [45] Evaluation and Optimization of a Two-Phase Liquid-Immersion Cooling System for Data Centers
    Liu, Cheng
    Yu, Hang
    ENERGIES, 2021, 14 (05)
  • [46] Energy efficiency optimization analysis for a cooling composite air conditioning system for internet data centers
    Li, Zhao
    Tong, Jihua
    Zheng, Zhuling
    Dong, Pengli
    Yang, Shangqing
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2024, 30 (09) : 1167 - 1181
  • [47] COOLING OF DATA CENTERS USING AIRSIDE ECONOMIZERS
    Karajgikar, Saket
    Mulay, Veerendra
    Agonafer, Dereje
    Schmidt, Roger
    IPACK 2009: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2009, VOL 2, 2010, : 1001 - 1007
  • [48] ASHRAE offers guidance on cooling data centers
    不详
    ASHRAE JOURNAL, 2004, 46 (02) : 9 - 9
  • [49] Joint Power Optimization Through VM Placement and Flow Scheduling in Data Centers
    Li, Dawei
    Wu, Jie
    Liu, Zhiyong
    Zhang, Fa
    2014 IEEE INTERNATIONAL PERFORMANCE COMPUTING AND COMMUNICATIONS CONFERENCE (IPCCC), 2014,
  • [50] Placement Optimization of Liquid-Cooled Servers for Power Minimization in Data Centers
    Li, Li
    Zheng, Wenli
    Wang, Xiaodong
    Wang, Xiaorui
    2014 INTERNATIONAL GREEN COMPUTING CONFERENCE (IGCC), 2014,