Coordinated Optimization of Cooling and IT Power in Data Centers

被引:11
|
作者
Samadiani, Emad [1 ]
Amur, Hrishikesh
Krishnan, Bhavani [2 ]
Joshi, Yogendra [1 ]
Schwan, Karsten [2 ]
机构
[1] Georgia Inst Technol, GW Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Coll Comp, Atlanta, GA 30332 USA
关键词
air conditioning; computer centres; cooling; power consumption; thermal management (packaging); ROBUST DESIGN;
D O I
10.1115/1.4001858
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Concurrency and exchanging design knowledge among thermal and IT management are required to achieve an energy efficient operational data center. In this paper, a design approach is presented to bring adaptability and concurrency for coordinated minimization of cooling and IT power consumption in data centers. The presented approach is centered on a proper orthogonal decomposition based reduced order thermal modeling approach, and power profiling of the IT equipment to identify the optimal parameters of the air cooling systems along with optimal dynamic workload distribution among the servers. The method is applied to a data center cell with different rack and server architectures. The results show that the design approach results in 12-70% saving in the total energy consumption of the data center cell for various scenarios, compared with a baseline design. [DOI: 10.1115/1.4001858]
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Power cost minimization in data centers Via Lyapunov optimization
    张然
    Wan Jianxiong
    High Technology Letters, 2016, 22 (04) : 355 - 361
  • [32] Cooling technology to reduce air-conditioning power consumption in data centers
    Yoshikawa, Minoru
    Nakai, Yasuhiro
    Kishino, Tsuyoshi
    NEC Technical Journal, 2016, 10 (02): : 42 - 45
  • [33] Data centers roadmap for datacom cooling
    Belady, CL
    Beaty, D
    ASHRAE JOURNAL, 2005, 47 (12) : 52 - 55
  • [34] Free cooling of data centers: A review
    Zhang, Hainan
    Shao, Shuangquan
    Xu, Hongbo
    Zou, Huiming
    Tian, Changqing
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 35 : 171 - 182
  • [35] Cooling-Aware Energy and Workload Management in Data Centers via Stochastic Optimization
    Chen, Tianyi
    Wang, Xin
    Giannakis, Georgios B.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2016, 10 (02) : 402 - 415
  • [36] The power of data centers
    Lucy, Jim
    EC and M: Electrical Construction and Maintenance, 2019, 118 (03):
  • [37] Effect of Virtualization on the Cooling Infrastructure's Power Consumption in Enclosed Aisle Data Centers
    Demetriou, Dustin W.
    Khalifa, H. Ezzat
    2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2012, : 358 - 366
  • [38] Electrical Design for a Combined Cooling, Heating and Power for Go-Green Data Centers
    Ngobeni, A.
    Chowdhury, S. P. Daniel
    2018 IEEE PES/IAS POWERAFRICA CONFERENCE, 2018, : 901 - 906
  • [39] Coordinated Optimization of Centralized and Decentralized Cooling Energy Supply
    Wang, L. X.
    Wei, F.
    Wu, Q. S.
    Wu, Q. H.
    Jing, Z. X.
    2016 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT-ASIA), 2016, : 687 - 692
  • [40] PowerNetS: Coordinating Data Center Network With Servers and Cooling for Power Optimization
    Zheng, Kuangyu
    Zheng, Wenli
    Li, Li
    Wang, Xiaorui
    IEEE TRANSACTIONS ON NETWORK AND SERVICE MANAGEMENT, 2017, 14 (03): : 661 - 675