Scope of detection and determination of gallium(III) in industrial ground water by square wave anodic stripping voltammetry on bismuth film electrode

被引:21
|
作者
Kamat, J. V. [1 ]
Guin, Saurav K. [1 ]
Pillai, Jisha S. [1 ]
Aggarwal, Suresh K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Bombay 400085, Maharashtra, India
关键词
Bismuth-film electrode; Gallium; Square wave anodic stripping voltammetry; Gaussian peak fit; Atomic force microscope; SILVER-BASED ELECTRODE; NEUTRON-ACTIVATION; PRECONCENTRATION; SEPARATION; ELECTROANALYSIS; SPECTROMETRY; EXTRACTION; ALUMINUM; SAMPLES; TRACES;
D O I
10.1016/j.talanta.2011.09.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gallium(III) in ground water may cause human health hazards due to the antineoplastic and antimicrobial activities of gallium. However, the exposure limit of Ga(III) has not been set. This paper demonstrates the scope of employing the square wave anodic stripping voltammetry (SWASV) on bismuth film electrode (BiFE) for selective and sensitive detection of Ga(III) as well as its accurate and precise determination. The key parameters were optimized and the bismuth film morphology was characterized. The performance of BiFE was also compared with that of the mercury film electrode (MFE). The performance of BiFE was also studied for interferences of Zn(II), Cd(II), TI(I) and Cu(II) ions. Gaussian peak fitting was performed to improve the calibration curve and the fitting process revealed almost similar stripping peak heights as obtained from the experimentally observed data though slight improvement in calibration was obtained from the peak area analysis. A good linear dynamic range (R(2) = 0.996) was obtained in the concentration range of 20-100 mu g/L with a limit of detection (LOD) of 6.6 mu g/L (S/N = 3) of Ga(III). A relative standard deviation of 2.9% (n = 10) was obtained for 20 mu g/L of Ga(III) solution. The practical analytical utility of the method was verified by the determination of Ga(III) in spiked water samples, where 100-105% recovery of Ga(III) was achieved. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 265
页数:10
相关论文
共 50 条
  • [31] Determination of Caffeine Using a Simple Graphite Pencil Electrode with Square-Wave Anodic Stripping Voltammetry
    Suw Young Ly
    Young Sam Jung
    Myung Hoon Kim
    In kwon Han
    Woon Won Jung
    Hyun Sook Kim
    Microchimica Acta, 2004, 146 : 207 - 213
  • [32] Determination of caffeine using a simple graphite pencil electrode with square-wave anodic stripping voltammetry
    Ly, SY
    Jung, YS
    Kim, MH
    Han, IK
    Jung, WW
    Kim, HS
    MICROCHIMICA ACTA, 2004, 146 (3-4) : 207 - 213
  • [33] Anodic Stripping Voltammetry with Pencil Graphite Electrode for Determination of Chromium (III)
    Wyantuti, S.
    Hafidza, R. A.
    Ishmayana, S.
    Hartati, Y. W.
    INTERNATIONAL SEMINAR ON MATHEMATICS, SCIENCE, AND COMPUTER SCIENCE EDUCATION (MSCEIS 2016), 2017, 812
  • [34] DETERMINATION OF COBALT BY ANODIC-STRIPPING VOLTAMMETRY AT A MERCURY FILM ELECTRODE
    BLOOM, H
    NOLLER, BN
    RICHARDSON, DE
    ANALYTICA CHIMICA ACTA, 1979, 109 (01) : 157 - 160
  • [35] Determination of trace arsenic(III) by differential-pulse anodic stripping voltammetry with in-situ plated bismuth-film electrode
    Long, Jiajie
    Nagaosa, Yukio
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (01) : 51 - 60
  • [36] Determination of antimony(III) and (V) in natural water by cathodic stripping voltammetry with in-situ plated bismuth film electrode
    Ping Zong
    Yukio Nagaosa
    Microchimica Acta, 2009, 166 : 139 - 144
  • [37] Determination of antimony(III) and (V) in natural water by cathodic stripping voltammetry with in-situ plated bismuth film electrode
    Zong, Ping
    Nagaosa, Yukio
    MICROCHIMICA ACTA, 2009, 166 (1-2) : 139 - 144
  • [38] Determination of Folic Acid at a Bismuth Film Electrode by Adsorptive Stripping Voltammetry
    Rutyna, Iwona
    ANALYTICAL LETTERS, 2015, 48 (10) : 1593 - 1603
  • [39] Bismuth Film Anodic Stripping Voltammetry for the Determination of Lead in Kerosene: A Metrological Study
    Miguel, Eliane M.
    da Cunha, Alessandra Licursi M. C.
    Pacheco, Wagner F.
    Farias, Percio A. M.
    Aucelio, Ricardo Q.
    ELECTROANALYSIS, 2010, 22 (13) : 1505 - 1510
  • [40] Quantitative determination of zinc in milkvetch by anodic stripping voltammetry with bismuth film electrodes
    Guo, ZY
    Feng, F
    Hou, YX
    Jaffrezic-Renault, N
    TALANTA, 2005, 65 (04) : 1052 - 1055