Scope of detection and determination of gallium(III) in industrial ground water by square wave anodic stripping voltammetry on bismuth film electrode

被引:21
|
作者
Kamat, J. V. [1 ]
Guin, Saurav K. [1 ]
Pillai, Jisha S. [1 ]
Aggarwal, Suresh K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Bombay 400085, Maharashtra, India
关键词
Bismuth-film electrode; Gallium; Square wave anodic stripping voltammetry; Gaussian peak fit; Atomic force microscope; SILVER-BASED ELECTRODE; NEUTRON-ACTIVATION; PRECONCENTRATION; SEPARATION; ELECTROANALYSIS; SPECTROMETRY; EXTRACTION; ALUMINUM; SAMPLES; TRACES;
D O I
10.1016/j.talanta.2011.09.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gallium(III) in ground water may cause human health hazards due to the antineoplastic and antimicrobial activities of gallium. However, the exposure limit of Ga(III) has not been set. This paper demonstrates the scope of employing the square wave anodic stripping voltammetry (SWASV) on bismuth film electrode (BiFE) for selective and sensitive detection of Ga(III) as well as its accurate and precise determination. The key parameters were optimized and the bismuth film morphology was characterized. The performance of BiFE was also compared with that of the mercury film electrode (MFE). The performance of BiFE was also studied for interferences of Zn(II), Cd(II), TI(I) and Cu(II) ions. Gaussian peak fitting was performed to improve the calibration curve and the fitting process revealed almost similar stripping peak heights as obtained from the experimentally observed data though slight improvement in calibration was obtained from the peak area analysis. A good linear dynamic range (R(2) = 0.996) was obtained in the concentration range of 20-100 mu g/L with a limit of detection (LOD) of 6.6 mu g/L (S/N = 3) of Ga(III). A relative standard deviation of 2.9% (n = 10) was obtained for 20 mu g/L of Ga(III) solution. The practical analytical utility of the method was verified by the determination of Ga(III) in spiked water samples, where 100-105% recovery of Ga(III) was achieved. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 265
页数:10
相关论文
共 50 条
  • [21] Box-Behnken response surface design for the optimization of electrochemical detection of cadmium by Square Wave Anodic Stripping Voltammetry on bismuth film/glassy carbon electrode
    Zhao, Guo
    Wang, Hui
    Liu, Gang
    Wang, Zhiqiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 235 : 67 - 73
  • [22] Bismuth film electrode for anodic stripping voltammetric determination of tin
    Hutton, Emily A.
    Hocevar, Sarno B.
    Mauko, Lea
    Ogorevc, Bozidar
    ANALYTICA CHIMICA ACTA, 2006, 580 (02) : 244 - 250
  • [23] Trace determination of chromium by square-wave adsorptive stripping voltammetry on bismuth film electrodes
    Chatzitheodorou, E
    Economou, A
    Voulgaropoulos, A
    ELECTROANALYSIS, 2004, 16 (21) : 1745 - 1754
  • [24] Anodic stripping voltammetry determination of Pb(II) and Cd(II) at a bismuth/poly(aniline) film electrode
    Zhu, Wei Wei
    Li, Nian Bing
    Luo, Hong Qun
    ANALYTICAL LETTERS, 2006, 39 (11) : 2273 - 2284
  • [25] Determination of trace lead by square-wave anodic stripping voltammetry
    Wang, Mingliang
    Li, Minjing
    Yejin Fenxi/Metallurgical Analysis, 2000, 20 (01): : 42 - 44
  • [26] Improving precision and trueness in the quantification of cadmium using square wave anodic stripping voltammetry and bismuth film electrodes
    Gonzalez-Basto, Maria Camila
    Espana-Sanchez, Carlos Andres
    Agreda, Jesus A.
    Sandoval-Rojas, Andrea del Pilar
    RESULTS IN CHEMISTRY, 2022, 4
  • [27] Determination of Trace Antimony by Square-Wave Adsorptive Cathodic Stripping Voltammetry at an Ex Situ Prepared Bismuth Film Electrode
    Su, Jiali
    Zhong, Shangwei
    Li, Xiangjun
    Zou, Hong
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (09) : H512 - H516
  • [28] Diagnostics of Anodic Stripping Mechanisms under Square-Wave Voltammetry Conditions Using Bismuth Film Substrates
    Mirceski, Valentin
    Hocevar, Samo B.
    Ogorevc, Bozidar
    Gulaboski, Rubin
    Drangov, Ivan
    ANALYTICAL CHEMISTRY, 2012, 84 (10) : 4429 - 4436
  • [29] Determination of Trace Lead and Cadmium in Water Samples by Anodic Stripping Voltammetry with a NafionIonic Liquid-Coated Bismuth Film Electrode
    Yang, Die
    Wang, Liang
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravi
    ELECTROANALYSIS, 2014, 26 (03) : 639 - 647
  • [30] Sensitive determination of paraquat by square wave anodic stripping voltammetry with chitin modified carbon paste electrode
    El Harmoudi, H.
    Achak, M.
    Farahi, A.
    Lahrich, S.
    El Gaini, L.
    Abdennouri, M.
    Bouzidi, A.
    Bakasse, M.
    El Mhammedi, M. A.
    TALANTA, 2013, 115 : 172 - 177