Impact of cleaning regimes on dental water unit contamination

被引:7
|
作者
Abdallah, Soad A. [1 ]
Khalil, Ahmed I. [2 ]
机构
[1] PAAET, Coll Nursing, Gen Sci Unit, Dept Microbiol, Kuwait, Kuwait
[2] Mubarak Al Kabeer Hosp, Head Prevent Med Dept, Kuwait, Kuwait
关键词
bacterial contamination; chlorination; dental unit waterline; flushing; MICROBIAL BIOFILM FORMATION; SYSTEMS; LINES; DISINFECTION; EFFICACY;
D O I
10.2166/wh.2011.184
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microorganisms that have been identified in dental unit waterlines (DUWLs) are of concern because they can cause infections, especially in immunocompromised patients. This study aimed to assess the incidence of microbial contamination in DUWLs before and after intervention to reduce contamination, and to investigate the presence of coliforms, Escherichia coli and Pseudomonas aeruginosa. Water samples were collected aseptically from the waterlines. The high-speed hand-piece and dental chair units were served by one distillation apparatus, which was fed by the potable tap water of four dental clinics. Different interventions were used: chlorination, flushing before clinics and between patients, draining at the end of the day, and freshly distilled water on a daily basis. There was a significant difference between the level of contamination in the high-speed hand-piece (1.5-2.7 log CFU/ml) and dental chair unit water (2.0-3.5 log CFU/ml). Coliforms (0.9%) E. coli (0.9%) and Pseudomonas (1.8%) were detected during 2008. This study indicates the need to monitor water quality regularly and prevent stagnation in DUWLs to reduce the number of viable bacteria to <100 CFU/ml. We recommend flushing the DUWL for 2 min before the first patient and for 10-20 s between patients, flushing the dental unit at the end of the day and draining it overnight to reduce the development of biofilms, and chlorination of the DUWLs.
引用
收藏
页码:647 / 652
页数:6
相关论文
共 50 条
  • [42] Monitoring of bacterial contamination of dental unit water lines using adenosine triphosphate bioluminescence
    Watanabe, A.
    Tamaki, N.
    Yokota, K.
    Matsuyama, M.
    Kokeguchi, S.
    JOURNAL OF HOSPITAL INFECTION, 2016, 94 (04) : 393 - 396
  • [43] Microbiological contamination of Dental Unit Water Systems in general practices from Barcelona (Spain)
    Araujo, R
    Contreras, N
    WATERBORNE PATHOGENS, 2004, 4 (02): : 1 - 5
  • [44] THE SOURCE, FREQUENCY AND EXTENT OF BACTERIAL-CONTAMINATION OF DENTAL UNIT WATER-SUPPLIES
    MARTIN, MV
    BARTZOKAS, CA
    BRITISH DENTAL JOURNAL, 1985, 158 (05) : 157 - 158
  • [45] THE SOURCE, FREQUENCY AND EXTENT OF BACTERIAL-CONTAMINATION OF DENTAL UNIT WATER-SYSTEMS
    FITZGIBBON, EJ
    BARTZOKAS, CA
    MARTIN, MV
    GIBSON, MF
    GRAHAM, R
    BRITISH DENTAL JOURNAL, 1984, 157 (03) : 98 - 101
  • [46] LEGIONELLA CONTAMINATION OF DENTAL-UNIT WATERS
    ATLAS, RM
    WILLIAMS, JF
    HUNTINGTON, MK
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (04) : 1208 - 1213
  • [47] Evaluation of mycological contamination of dental unit waterlines
    Szymanska, J
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2005, 12 (01) : 153 - 155
  • [48] Comamonas acidovorans contamination of dental unit waters
    Stampi, S
    Zanetti, F
    Bergamaschi, A
    De Luca, G
    LETTERS IN APPLIED MICROBIOLOGY, 1999, 29 (01) : 52 - 55
  • [49] Microbial contamination in dental unit airlines.
    Miller, CH
    Waskow, JR
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 2163 - 2163
  • [50] Water cleaning systems improves the water quality in dental unit water lines (DUWL). A report from the Public Dental Health of Vastra Gotaland region, Sweden
    Dahlen, Gunnar
    Hjort, Gunilla
    Spencer, Inger