Impact of cleaning regimes on dental water unit contamination

被引:7
|
作者
Abdallah, Soad A. [1 ]
Khalil, Ahmed I. [2 ]
机构
[1] PAAET, Coll Nursing, Gen Sci Unit, Dept Microbiol, Kuwait, Kuwait
[2] Mubarak Al Kabeer Hosp, Head Prevent Med Dept, Kuwait, Kuwait
关键词
bacterial contamination; chlorination; dental unit waterline; flushing; MICROBIAL BIOFILM FORMATION; SYSTEMS; LINES; DISINFECTION; EFFICACY;
D O I
10.2166/wh.2011.184
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microorganisms that have been identified in dental unit waterlines (DUWLs) are of concern because they can cause infections, especially in immunocompromised patients. This study aimed to assess the incidence of microbial contamination in DUWLs before and after intervention to reduce contamination, and to investigate the presence of coliforms, Escherichia coli and Pseudomonas aeruginosa. Water samples were collected aseptically from the waterlines. The high-speed hand-piece and dental chair units were served by one distillation apparatus, which was fed by the potable tap water of four dental clinics. Different interventions were used: chlorination, flushing before clinics and between patients, draining at the end of the day, and freshly distilled water on a daily basis. There was a significant difference between the level of contamination in the high-speed hand-piece (1.5-2.7 log CFU/ml) and dental chair unit water (2.0-3.5 log CFU/ml). Coliforms (0.9%) E. coli (0.9%) and Pseudomonas (1.8%) were detected during 2008. This study indicates the need to monitor water quality regularly and prevent stagnation in DUWLs to reduce the number of viable bacteria to <100 CFU/ml. We recommend flushing the DUWL for 2 min before the first patient and for 10-20 s between patients, flushing the dental unit at the end of the day and draining it overnight to reduce the development of biofilms, and chlorination of the DUWLs.
引用
收藏
页码:647 / 652
页数:6
相关论文
共 50 条
  • [31] Control of planktonic and biofilm contamination in a laboratory dental unit water system.
    Walker, JT
    Bradshaw, DJ
    Fulford, MR
    Martin, MV
    Marsh, PD
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A445 - A445
  • [32] Control of microbial contamination in dental unit waterlines: Effectiveness of neutral electrolytic water
    Mishima, Sayaka
    Watanabe, Takuma
    Fukuhara, Shizuko
    Ymanaka, Shigeki
    Nakao, Kazumasa
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2025, 37 (03) : 512 - 517
  • [33] Evaluation of dental unit water fungi contamination using petrifilm™ YM.
    Watanabe, E.
    Agostinho, A. M.
    Matsumoto, W.
    Ito, I. Y.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B79 - B79
  • [34] Contamination of dental unit waterlines: assessment of three continuous water disinfection systems
    Damien Offner
    Florence Fioretti
    Anne-Marie Musset
    BDJ Open, 2 (1)
  • [35] A review of biofilms and their role in microbial contamination of dental unit water systems (DUWS)
    Walker, JT
    Marsh, PD
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2004, 54 (2-3) : 87 - 98
  • [36] Appraisal of microbial contamination of dental unit water systems and practices of general dental practitioners for risk reduction
    Bajrang Lal
    Khaiwal Ravindra
    Manisha Biswal
    Environmental Science and Pollution Research, 2018, 25 : 33566 - 33572
  • [37] Appraisal of microbial contamination of dental unit water systems and practices of general dental practitioners for risk reduction
    Lal, Bajrang
    Ravindra, Khaiwal
    Biswal, Manisha
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (33) : 33566 - 33572
  • [38] Effects of two different source waters and cleaning dental unit water systems.
    Puttaiah, R
    Slattery, P
    Plamondon, TJ
    Mille, SE
    Cottone, JA
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 2165 - 2165
  • [39] Cleaning efficiency of Ster4 spray on dental unit water lines during dental practice.
    Montebugnoli, L
    Cervellati, F
    Vasconi, L
    Prati, C
    Dolci, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B251 - B251
  • [40] Effectiveness and safety of low-concentrated ozonized water for the reduction of contamination in dental unit water lines
    Okubo, Keisuke
    Ito, Takashi
    Shiota, Yasuyoshi
    Kawata, Yusuke
    Yamamoto, Tadashi
    Takashiba, Shogo
    HELIYON, 2019, 5 (08)