The impact of dual energy CT imaging on dose calculations for pre-clinical studies

被引:18
|
作者
Vaniqui, Ana [1 ]
Schyns, Lotte E. J. R. [1 ]
Almeida, Isabel P. [1 ]
van der Heyden, Brent [1 ]
van Hoof, Stefan J. [1 ]
Verhaegen, Frank [1 ]
机构
[1] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
关键词
Dual energy CT; Small animal radiotherapy; Dose calculations; Tissue segmentation; Monte Carlo; Pre-clinical; TISSUE SEGMENTATION; RADIOTHERAPY; BRACHYTHERAPY; IRRADIATION; ACCURACY; NUMBERS;
D O I
10.1186/s13014-017-0922-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To investigate the feasibility of using dual-energy CT (DECT) for tissue segmentation and kilovolt (kV) dose calculations in pre-clinical studies and assess potential dose calculation accuracy gain. Methods: Two phantoms and an ex-vivo mouse were scanned in a small animal irradiator with two distinct energies. Tissue segmentation was performed with the single-energy CT (SECT) and DECT methods. A number of different material maps was used. Dose calculations were performed to verify the impact of segmentations on the dose accuracy. Results: DECT showed better overall results in comparison to SECT. Higher number of DECT segmentation media resulted in smaller dose differences in comparison to the reference. Increasing the number of materials in the SECT method yielded more instability. Both modalities showed a limit to which adding more materials with similar characteristics ceased providing better segmentation results, and resulted in more noise in the material maps and the dose distributions. The effect was aggravated with a decrease in beam energy. For the ex-vivo specimen, the choice of only one high dense bone for the SECT method resulted in large volumes of tissue receiving high doses. For the DECT method, the choice of more than one kind of bone resulted in lower dose values for the different tissues occupying the same volume. For the organs at risk surrounded by bone, the doses were lower when using the SECT method in comparison to DECT, due to the high absorption of the bone. SECT material segmentation may lead to an underestimation of the dose to OAR in the proximity of bone. Conclusions: The DECT method enabled the selection of a higher number of materials thereby increasing the accuracy in dose calculations. In phantom studies, SECT performed best with three materials and DECT with seven for the phantom case. For irradiations in preclinical studies with kV photon energies, the use of DECT segmentation combined with the choice of a low-density bone is recommended.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Pre-clinical evaluation of a respiratory motion correction technique in dual gated cardiac imaging
    Lamare, Frederic
    Rimoldi, Ornella
    Teras, Mika
    Kokki, Tommi
    Knuuti, Juhani
    Visvikis, Dimitris
    Camici, Paolo
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [22] Optimization and performance study of a proton CT system for pre-clinical small animal imaging
    Meyer, Sebastian
    Bortfeldt, Jonathan
    Lammer, Paulina
    Englbrecht, Franz S.
    Pinto, Marco
    Schnuerle, Katrin
    Wuerl, Matthias
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [23] Contrast enhanced μCT imaging of early articular changes in a pre-clinical model of osteoarthritis
    Reece, D. S.
    Thote, T.
    Lin, A. S. P.
    Willett, N. J.
    Guldberg, R. E.
    OSTEOARTHRITIS AND CARTILAGE, 2018, 26 (01) : 118 - 127
  • [24] Angiogenesis in Pancreatic Cancer: Pre-Clinical and Clinical Studies
    Annese, Tiziana
    Tamma, Roberto
    Ruggieri, Simona
    Ribatti, Domenico
    CANCERS, 2019, 11 (03)
  • [25] Clinical Implementation of Dual-Energy CT for Gastrointestinal Imaging
    Mileto, Achille
    Ananthakrishnan, Lakshmi
    Morgan, Desiree E.
    Yeh, Benjamin M.
    Marin, Daniele
    Kambadakone, Avinash R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (03) : 651 - 662
  • [26] Neonatal encephalopathy: pre-clinical studies in neuroprotection
    Patel, Shyama D.
    Pierce, Leslie
    Ciardiello, Amber J.
    Vannucci, Susan J.
    BIOCHEMICAL SOCIETY TRANSACTIONS, 2014, 42 : 564 - 568
  • [27] Pre-clinical studies with tumor suppressor genes
    Seth, P
    CANCER GENE THERAPY, 2000, 465 : 183 - 192
  • [28] Sexual dimorphism in pre-clinical studies of depression
    Alshammari, Tahani K.
    PROGRESS IN NEURO-PSYCHOPHARMACOLOGY & BIOLOGICAL PSYCHIATRY, 2021, 105
  • [29] MicroRNAs and fracture healing: Pre-clinical studies
    Komatsu, David E.
    Duque, Edie
    Hadjiargyrou, Michael
    BONE, 2021, 143
  • [30] Pre-clinical studies of BRAF signalling in cancer
    Marais, R.
    EJC SUPPLEMENTS, 2007, 5 (04): : 44 - 45