A prototype quantitative film scanner for radiochromic film dosimetry

被引:14
|
作者
Ranade, Manisha K.
Li, Jonathan G.
Dubose, Ryan S. [1 ]
Kozelka, Jakub [2 ]
Simon, William E. [2 ]
Dempsey, James F.
机构
[1] Spartanburg Reg Hosp Gibbs Canc Ctr, Spartanburg, SC 29303 USA
[2] Sun Nucl Corp, Melbourne, FL 32940 USA
关键词
densitometer; film dosimetry; radiochromic film;
D O I
10.1118/1.2828203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a high resolution, quantitative, two-dimensional optical film scanner for use with a commercial high sensitivity radiochromic film (RCF) for measuring single fraction externalbeam radiotherapy dose distributions. The film scanner was designed to eliminate artifacts commonly observed in RC,F dosimetry. The scanner employed a stationary light source and detector with a moving antireflective glass film platen attached to a high precision computerized X-Y translation stage. An ultrabright red light emitting diode (LED) with a peak output at 633 nm and full width at half maximum (FWHM) of 16 nm was selected as the scanner light source to match the RCF absorption peak. A dual detector system was created using two silicon photodiode detectors to simultaneously measure incident and transmitted light. The LED light output was focused to a submillimeter (FWHM 0.67 mm) spot size, which was determined from a scanning knife-edge technique for measuring Gaussian optical beams. Data acquisition was performed with a 16-bit A/D card in conjunction with commercial software. The linearity of the measured densities on the scanner was tested using a calibrated neutral-density step filter. Sensitometric curves and three IMRT field scans were acquired with a spatial resolution of I mm for both radiographic film and RCR The results were compared with measurements taken with a commercial diode array under identical delivery conditions. The RCF was rotated by. 90 deg and. rescanned to study orientation effects. Comparison between the RCF and the diode array measurements using percent dose difference and distance-to-agreement criteria produced average passing rates of 99.0% using 3%/3 rum criteria and 96.7% using 2%/2 rum criteria. The same comparison between the radiographic film and diode array measurements resulted in average passing rates 96.6% and 91.6% for the above two criteria, respectively. No measurable light-scatter or interference scanner artifacts were observed. The RCF rotated by 90 deg showed no measurable orientation effect. A scan of a 15 X 15 cm(2) area with I turn resolution required 22 min to acquire. The LED densitometer provides an accurate film dosimetry system with 4 rum or better resolution. The scanner eliminates the orientation dependence of RCF dosimetry that was previously reported with commercial flatbed scanners. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:473 / 479
页数:7
相关论文
共 50 条
  • [41] Dosimetry using a radiochromic film and a mammography phantom
    Gotanda, Tatsuhiro
    Kawaji, Yasuyuki
    Yatake, Hidetoshi
    Imai, Shinya
    Akagawa, Takuya
    Katsuda, Toshizo
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (8-9) : 1007 - 1011
  • [42] Radiochromic film dosimetry: Past, present, and future
    Devic, Slobodan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2011, 27 (03): : 122 - 134
  • [43] Radiochromic film dosimetry for clinical proton beams
    Vatnitsky, SM
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (05) : 643 - 651
  • [44] RADIOCHROMIC FILM DOSIMETRY: COMPUTER CONTROLLED DENSITOMETER
    Sipila, P.
    Jarvinen, H.
    Jokelainen, I.
    Ojala, J.
    Niemela, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S476 - S476
  • [45] Effect of Magnetic Field in Radiochromic Film Dosimetry
    Volotskova, O.
    Fang, X.
    Keidar, M.
    Chandarana, H.
    Das, I.
    MEDICAL PHYSICS, 2017, 44 (06) : 3136 - 3136
  • [46] Radiochromic Film Dosimetry and its Applications in Radiotherapy
    Williams, Matthew
    Metcalfe, Peter
    CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 75 - +
  • [47] Computed tomography phantom for radiochromic film dosimetry
    Gotanda, R.
    Katsuda, T.
    Gotanda, T.
    Eguchi, M.
    Takewa, S.
    Tabuchi, A.
    Yatake, H.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (03) : 194 - 199
  • [48] On the characterization and uncertainty analysis of radiochromic film dosimetry
    Bouchard, Hugo
    Lacroix, Frederic
    Beaudoin, Gilles
    Carrier, Jean-Francois
    Kawrakow, Iwan
    MEDICAL PHYSICS, 2009, 36 (06) : 1931 - 1946
  • [49] Optimizing the recalibration process in radiochromic film dosimetry
    Ruiz-Morales, Carmen
    Vera-Sanchez, Juan Antonio
    Gonzalez-Lopez, Antonio
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (01):
  • [50] Noise in radiochromic film dosimetry with a CCD digitizer
    Gonzalez-Lopez, A
    Buades-Forner, M
    Quinones, L
    Arjona, J
    Tabarra-Gonzalez, J
    Torres-Donaire, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S143 - S144