A prototype quantitative film scanner for radiochromic film dosimetry

被引:14
|
作者
Ranade, Manisha K.
Li, Jonathan G.
Dubose, Ryan S. [1 ]
Kozelka, Jakub [2 ]
Simon, William E. [2 ]
Dempsey, James F.
机构
[1] Spartanburg Reg Hosp Gibbs Canc Ctr, Spartanburg, SC 29303 USA
[2] Sun Nucl Corp, Melbourne, FL 32940 USA
关键词
densitometer; film dosimetry; radiochromic film;
D O I
10.1118/1.2828203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a high resolution, quantitative, two-dimensional optical film scanner for use with a commercial high sensitivity radiochromic film (RCF) for measuring single fraction externalbeam radiotherapy dose distributions. The film scanner was designed to eliminate artifacts commonly observed in RC,F dosimetry. The scanner employed a stationary light source and detector with a moving antireflective glass film platen attached to a high precision computerized X-Y translation stage. An ultrabright red light emitting diode (LED) with a peak output at 633 nm and full width at half maximum (FWHM) of 16 nm was selected as the scanner light source to match the RCF absorption peak. A dual detector system was created using two silicon photodiode detectors to simultaneously measure incident and transmitted light. The LED light output was focused to a submillimeter (FWHM 0.67 mm) spot size, which was determined from a scanning knife-edge technique for measuring Gaussian optical beams. Data acquisition was performed with a 16-bit A/D card in conjunction with commercial software. The linearity of the measured densities on the scanner was tested using a calibrated neutral-density step filter. Sensitometric curves and three IMRT field scans were acquired with a spatial resolution of I mm for both radiographic film and RCR The results were compared with measurements taken with a commercial diode array under identical delivery conditions. The RCF was rotated by. 90 deg and. rescanned to study orientation effects. Comparison between the RCF and the diode array measurements using percent dose difference and distance-to-agreement criteria produced average passing rates of 99.0% using 3%/3 rum criteria and 96.7% using 2%/2 rum criteria. The same comparison between the radiographic film and diode array measurements resulted in average passing rates 96.6% and 91.6% for the above two criteria, respectively. No measurable light-scatter or interference scanner artifacts were observed. The RCF rotated by 90 deg showed no measurable orientation effect. A scan of a 15 X 15 cm(2) area with I turn resolution required 22 min to acquire. The LED densitometer provides an accurate film dosimetry system with 4 rum or better resolution. The scanner eliminates the orientation dependence of RCF dosimetry that was previously reported with commercial flatbed scanners. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:473 / 479
页数:7
相关论文
共 50 条
  • [31] Accuracy And Reproducibility Of Radiochromic Film Dosimetry
    Laosa, C.
    Calvo-Ortega, J. F.
    Moragues, S.
    Casals, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S916 - S916
  • [32] Model selection for radiochromic film dosimetry
    Mendez, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10): : 4089 - 4104
  • [33] Dosimetry of blood irradiation with radiochromic film
    Butson, MJ
    Yu, PKN
    Cheung, T
    Carolan, MG
    Quach, KY
    Arnold, A
    Metcalfe, PE
    TRANSFUSION MEDICINE, 1999, 9 (03) : 205 - 208
  • [34] The performance of an optical cone-beam CT scanner adapted for radiochromic film dosimetry
    Babic, Steven
    Jordan, Kevin
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21): : N377 - N389
  • [35] Temporal Characterization of the Flat-Bed Scanner Influencing Dosimetry Using Radiochromic Film
    Gotanda, Rumi
    Katsuda, Toshizo
    Gotanda, Tatsuhiro
    Tanki, Nobuyoshi
    Yatake, Hidetoshi
    Kawaji, Yasuyuki
    Kuwano, Tadao
    Akagawa, Takuya
    Tabuchi, Akihiko
    Ono, Atsushi
    Arao, Shinichi
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 537 - 539
  • [36] A method of increasing the film intrinsic robustness of radiochromic film dosimetry
    Ebongue, A. Ngwa
    Srivastava, R. P.
    Njock, M. G. Kwato
    De Wagter, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22): : N445 - N456
  • [37] The origin of the flatbed scanner artifacts in radiochromic film dosimetry-key experiments and theoretical descriptions
    Schoenfeld, Andreas A.
    Wieker, Soeren
    Harder, Dietrich
    Poppe, Bjoern
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (21): : 7704 - 7724
  • [38] A THICKNESS INDEPENDENT RADIOCHROMIC FILM DOSIMETRY SYSTEM
    RICKEY, JD
    HUMPHERYS, KC
    RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6): : 753 - 756
  • [39] A new method of readout in radiochromic film dosimetry
    Kellermann, PO
    Ertl, A
    Gornik, E
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08): : 2251 - 2263
  • [40] Evaluation of a LED-based flatbed document scanner for radiochromic film dosimetry in transmission mode
    Manuel Larraga-Gutierrez, Jose
    Amanda Garcia-Garduno, Olivia
    Trevino-Palacios, Carlos
    Alfredo Herrera-Gonzalez, Jose
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 47 : 86 - 91