Influence of Temperature on the Biomechanical Stability of Titanium, PEEK, Poly-L-Lactic Acid, and β-Tricalcium Phosphate Poly-L-Lactic Acid Suture Anchors Tested on Human Humeri In Vitro in a Wet Environment

被引:9
|
作者
Guelecyuez, Mehmet F. [1 ]
Mazur, Alexandra [2 ]
Schroeder, Christian [2 ]
Braun, Christian [3 ]
Ficklscherer, Andreas [1 ]
Rossbach, Bjoern P. [1 ]
Mueller, Peter E. [1 ]
Pietschmann, Matthias F. [1 ]
机构
[1] Univ Munich, Dept Orthopaed Phys Med & Rehabil, D-81377 Munich, Germany
[2] Univ Munich, Lab Biomech & Expt Orthopaed, D-81377 Munich, Germany
[3] Univ Munich, Dept Forens Med, D-81377 Munich, Germany
关键词
ROTATOR CUFF REPAIR; MECHANICAL STRENGTH; CYCLIC LOAD; FAILURE STRENGTH; BONE; FIXATION; DENSITY;
D O I
10.1016/j.arthro.2014.12.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to analyze the biomechanical integrity of suture anchors of different materials (titanium, PEEK [polyether ether ketone], poly-L-lactic acid [PLLA], and beta-tricalcium phosphate PLLA) and almost identical design for rotator cuff repair in human humeri positioned in a water bath at room and body temperature undergoing cyclic loading rather than single-pull or static tests. Methods: Four different anchor models (n = 6) were tested using healthy human cadaveric humeri in a water bath thermostatically regulated at 20 degrees C and 37 degrees C. A cyclic testing protocol was used. The maximum failure load, the system displacement, and the respective mode of failure were recorded. Results: There were no significant differences regarding the maximum failure load values between the 20 degrees C groups and 37 degrees C groups for the 4 different anchor materials. The displacement values for the 20 degrees C groups and 37 degrees C groups also were not statistically significant. Anchor and suture dislocations were the predominant modes of failure; suture ruptures were observed in few cases. Conclusions: This study shows that there are no significantly relevant differences regarding the maximum failure loads and the displacement values of the tested suture anchor systems in a wet environment at 20 degrees C or 37 degrees C. The temperature differences do not seem to affect the modes of failure either.
引用
收藏
页码:1134 / 1141
页数:8
相关论文
共 50 条
  • [41] Light modulation by biodegradatic poly-L-lactic acid film
    Tajitsu, Y
    Makino, K
    Saito, A
    Ebina, M
    Okuno, M
    Shikinami, Y
    Date, M
    Fukada, E
    JOURNAL OF MATERIALS SCIENCE LETTERS, 2000, 19 (17) : 1537 - 1539
  • [42] Langmuir Films of Poly-L-lactic Acid - Their Nucleation and Growth
    Vitaskova, Anna
    Kvitek, Libor
    CHEMICKE LISTY, 2018, 112 (06): : 346 - 353
  • [43] Poly-L-lactic acid for the Improvement of photodamage and rhytids of the decolletage
    Wilkerson, Eric C.
    Goldberg, David J.
    JOURNAL OF COSMETIC DERMATOLOGY, 2018, 17 (04) : 606 - 610
  • [44] Poly-l-Lactic Acid for Minimally Invasive Gluteal Augmentation
    Lin, Matthew J.
    Dubin, Danielle P.
    Khorasani, Hooman
    DERMATOLOGIC SURGERY, 2020, 46 (03) : 386 - 394
  • [45] FDA Approves Poly-L-Lactic Acid for Nasolabial Folds
    不详
    JOURNAL OF DRUGS IN DERMATOLOGY, 2009, 8 (10) : 959 - 959
  • [46] Poly-L-Lactic Acid Preinjection Aspiration as a Safety Checkpoint
    Lin, Matthew J.
    Chu, Justin
    DERMATOLOGIC SURGERY, 2021, 47 (04) : 576 - 577
  • [47] A new option for volumetric restoration: poly-L-lactic acid
    Thioly-Bensoussan, D.
    JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2006, 20 : 12 - 16
  • [48] Treatment of the aged hand with injectable poly-L-lactic acid
    Rendon, Marta I.
    Cardona, Lina M.
    Pinzon-Plazas, Mariana
    JOURNAL OF COSMETIC AND LASER THERAPY, 2010, 12 (06) : 284 - 287
  • [49] Marrow cell culture on poly-L-lactic acid fabrics
    Hasegawa, Y
    Ohgushi, H
    Ishimura, M
    Habata, T
    Tamai, S
    Tomita, N
    Ikada, Y
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (358) : 235 - 243
  • [50] Facial volumetic correction with injectable poly-L-lactic acid
    Vleggaar, D
    DERMATOLOGIC SURGERY, 2005, 31 (11) : 1511 - 1518