Influence of Temperature on the Biomechanical Stability of Titanium, PEEK, Poly-L-Lactic Acid, and β-Tricalcium Phosphate Poly-L-Lactic Acid Suture Anchors Tested on Human Humeri In Vitro in a Wet Environment

被引:9
|
作者
Guelecyuez, Mehmet F. [1 ]
Mazur, Alexandra [2 ]
Schroeder, Christian [2 ]
Braun, Christian [3 ]
Ficklscherer, Andreas [1 ]
Rossbach, Bjoern P. [1 ]
Mueller, Peter E. [1 ]
Pietschmann, Matthias F. [1 ]
机构
[1] Univ Munich, Dept Orthopaed Phys Med & Rehabil, D-81377 Munich, Germany
[2] Univ Munich, Lab Biomech & Expt Orthopaed, D-81377 Munich, Germany
[3] Univ Munich, Dept Forens Med, D-81377 Munich, Germany
关键词
ROTATOR CUFF REPAIR; MECHANICAL STRENGTH; CYCLIC LOAD; FAILURE STRENGTH; BONE; FIXATION; DENSITY;
D O I
10.1016/j.arthro.2014.12.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to analyze the biomechanical integrity of suture anchors of different materials (titanium, PEEK [polyether ether ketone], poly-L-lactic acid [PLLA], and beta-tricalcium phosphate PLLA) and almost identical design for rotator cuff repair in human humeri positioned in a water bath at room and body temperature undergoing cyclic loading rather than single-pull or static tests. Methods: Four different anchor models (n = 6) were tested using healthy human cadaveric humeri in a water bath thermostatically regulated at 20 degrees C and 37 degrees C. A cyclic testing protocol was used. The maximum failure load, the system displacement, and the respective mode of failure were recorded. Results: There were no significant differences regarding the maximum failure load values between the 20 degrees C groups and 37 degrees C groups for the 4 different anchor materials. The displacement values for the 20 degrees C groups and 37 degrees C groups also were not statistically significant. Anchor and suture dislocations were the predominant modes of failure; suture ruptures were observed in few cases. Conclusions: This study shows that there are no significantly relevant differences regarding the maximum failure loads and the displacement values of the tested suture anchor systems in a wet environment at 20 degrees C or 37 degrees C. The temperature differences do not seem to affect the modes of failure either.
引用
收藏
页码:1134 / 1141
页数:8
相关论文
共 50 条
  • [21] Poly-L-lactic acid for facial lipoatrophy in HIV
    El-Beyrouty, Claudine
    Huang, Vanthida
    Darnold, Courtney J.
    Clay, Patrick G.
    ANNALS OF PHARMACOTHERAPY, 2006, 40 (09) : 1602 - 1606
  • [22] Alopecia Induced by Poly-L-Lactic Acid Injection
    Cortez, Gabriel Lazzeri
    Hassun, Karime Marques
    Linhares, Luciana Ribeiro Patricio
    Pinheiro, Maria Valeria Bussamara
    Florenco, Verena
    Michalany, Nilceo Schwery
    Bagatin, Edileia
    de Almeida, Rita Fernanda Cortez
    Melo, Daniel Fernandes
    do Nascimento, Mauricio Mendonca
    CUTIS, 2024, 114 (05): : 159 - 161
  • [23] Poly-L-lactic acid: consultation on the injection techniques
    Vleggaar, D
    JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2006, 20 : 17 - 21
  • [24] Poly-L-Lactic Acid for Nonfacial Skin Laxity
    Mazzuco, Rosemarie
    Dal'Forno, Taciana
    Hexsel, Doris
    DERMATOLOGIC SURGERY, 2020, 46 : S86 - S88
  • [25] Poly-l-Lactic Acid for Neck and Chest Rejuvenation
    Mazzuco, Rosemarie
    Hexsel, Doris
    DERMATOLOGIC SURGERY, 2009, 35 (08) : 1228 - 1237
  • [26] Poly-L-lactic acid - A viewpoint by Graeme Moyle
    Moyle, G
    AMERICAN JOURNAL OF CLINICAL DERMATOLOGY, 2004, 5 (05) : 367 - 367
  • [27] OPTICAL-ACTIVITY OF POLY-L-LACTIC ACID
    ASAHI, T
    FUKASE, H
    ICHIKI, M
    KOBAYASHI, J
    FUKADA, E
    FERROELECTRICS, 1990, 109 : 339 - 342
  • [28] Compositions of injectable poly-d,l-lactic acid and injectable poly-l-lactic acid
    Chen, S. Y.
    Lin, J. Y.
    Lin, C. Y.
    CLINICAL AND EXPERIMENTAL DERMATOLOGY, 2020, 45 (03) : 347 - 348
  • [29] In vitro degradation of fibrous bilayer poly-L-lactic acid scaffolds
    Molina, Maria I. Echeverria
    Komvopoulos, Kyriakos
    JOURNAL OF BIOMECHANICS, 2023, 161
  • [30] The use of poly-L-lactic acid in lumbar interbody cages: design and biomechanical evaluation in vitro
    van Dijk, M
    Smit, TH
    Arnoe, MF
    Burger, EH
    Wuisman, PI
    EUROPEAN SPINE JOURNAL, 2003, 12 (01) : 34 - 40